scholarly journals Combined Selective Cerebral Hypothermia and Mechanical Artery Recanalization in Acute Ischemic Stroke: In Vitro Study of Cooling Performance

2015 ◽  
Vol 36 (11) ◽  
pp. 2114-2120 ◽  
Author(s):  
G. Cattaneo ◽  
M. Schumacher ◽  
J. Wolfertz ◽  
T. Jost ◽  
S. Meckel
Author(s):  
Jawid Madjidyar ◽  
Lars Nerkada ◽  
Naomi Larsen ◽  
Fritz Wodarg ◽  
Johannes Hensler ◽  
...  

Purpose A direct aspiration first pass technique (ADAPT) is an effective thrombectomy option in patients with acute ischemic stroke. Balloon guide catheters (BGC) seem to improve the efficacy of stent retrievers and ADAPT. The last generation 6F aspiration catheters require 9F BGCs, which are rigid devices that are challenging to position in a tortuous anatomy. In this experimental study the efficacy of 6F ADAPT alone and 5F ADAPT combined with 8F BGC was evaluated. Materials and Methods Either a fibrin rich (white) clot or an RBC rich (red) clot was placed in the M1 segment of a transparent silicon phantom. Physiological hemodynamic conditions were maintained. The clots were retrieved by 6F aspiration catheter via 8F long sheath or 5F aspiration catheter via a flexible 8F BGC. Thrombectomy was performed under direct visual control. The primary endpoints were the number of passes and the number of distal emboli. Results Ten experiments were made with each clot model and thrombectomy technique (n = 40). Full recanalization could be achieved in every experiment. First pass mTICI 3 could be achieved by 6F ADAPT in 80 % of red clots and 90 % of white clots. Distal emboli were caused in 10 % and 20 %, respectively. When using 5F ADAPT combined with BGC, a first pass mTICI 3 rate of 90 % in red clots and 100 % in white clots could be achieved. A 10 % rate of distal emboli occurred in both groups. In almost all experiments (both techniques), the thrombi clogged the aspiration catheter. No statistically significant differences could be found between the techniques and clot models. Conclusion 6F ADAPT without BGC was as effective as 5F ADAPT combined with a flexible 8F BGC, with both techniques showing high first-pass recanalization rates and low distal emboli rates. Especially in the case of a tortuous anatomy, these setups should be considered as alternatives to a rigid 9F BGC. The thrombus compositions seemed to be irrelevant in this setting. Key Points:  Citation Format


2017 ◽  
Vol 23 (3) ◽  
pp. 279-284 ◽  
Author(s):  
Waleed Brinjikji ◽  
Gregory Michalak ◽  
Ramanathan Kadirvel ◽  
Daying Dai ◽  
Michael Gilvarry ◽  
...  

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.


Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
EM Pferschy-Wenzig ◽  
K Koskinen ◽  
C Moissl-Eichinger ◽  
R Bauer

2003 ◽  
Vol 48 (1) ◽  
pp. 7 ◽  
Author(s):  
Dong Hyun Kim ◽  
Sung Gwon Kang ◽  
Sang Soo Park ◽  
Don Haeng Lee ◽  
Gyu Baek Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document