scholarly journals Choosing an Effective and Safe Direct Aspiration Setup for Tortuous Anatomy in Acute Ischemic Stroke: In vitro Study in a Physiological Flow Model

Author(s):  
Jawid Madjidyar ◽  
Lars Nerkada ◽  
Naomi Larsen ◽  
Fritz Wodarg ◽  
Johannes Hensler ◽  
...  

Purpose A direct aspiration first pass technique (ADAPT) is an effective thrombectomy option in patients with acute ischemic stroke. Balloon guide catheters (BGC) seem to improve the efficacy of stent retrievers and ADAPT. The last generation 6F aspiration catheters require 9F BGCs, which are rigid devices that are challenging to position in a tortuous anatomy. In this experimental study the efficacy of 6F ADAPT alone and 5F ADAPT combined with 8F BGC was evaluated. Materials and Methods Either a fibrin rich (white) clot or an RBC rich (red) clot was placed in the M1 segment of a transparent silicon phantom. Physiological hemodynamic conditions were maintained. The clots were retrieved by 6F aspiration catheter via 8F long sheath or 5F aspiration catheter via a flexible 8F BGC. Thrombectomy was performed under direct visual control. The primary endpoints were the number of passes and the number of distal emboli. Results Ten experiments were made with each clot model and thrombectomy technique (n = 40). Full recanalization could be achieved in every experiment. First pass mTICI 3 could be achieved by 6F ADAPT in 80 % of red clots and 90 % of white clots. Distal emboli were caused in 10 % and 20 %, respectively. When using 5F ADAPT combined with BGC, a first pass mTICI 3 rate of 90 % in red clots and 100 % in white clots could be achieved. A 10 % rate of distal emboli occurred in both groups. In almost all experiments (both techniques), the thrombi clogged the aspiration catheter. No statistically significant differences could be found between the techniques and clot models. Conclusion 6F ADAPT without BGC was as effective as 5F ADAPT combined with a flexible 8F BGC, with both techniques showing high first-pass recanalization rates and low distal emboli rates. Especially in the case of a tortuous anatomy, these setups should be considered as alternatives to a rigid 9F BGC. The thrombus compositions seemed to be irrelevant in this setting. Key Points:  Citation Format

Author(s):  
Naomi Larsen ◽  
Katharina Oberbeck ◽  
Rodrigo Lima de Miranda ◽  
Jens Trentmann ◽  
Jawid Madjidyar ◽  
...  

Purpose Various stent retrievers differing in stent design and mechanical properties are currently available for the treatment of ischemic stroke. We conducted this in vitro study to compare the efficacy, embolism rate, and safety of commercially available stent retrievers and prototypes. Materials and Methods Whole blood thrombi were produced in a Chandler loop. The thrombi were inserted into the curved M1 segment of a silicone model of the anterior cerebral circulation. Thrombectomy maneuvers were performed with six commercially available stent retrievers and 2 prototypes with different strut thickness. Wall-stent apposition, first pass recanalization rate, retraction force, and embolism rate were compared. Results Devices with complete wall-stent apposition had the highest first pass recanalization rate and lowest embolism rate, but showed the highest retraction force. The prototype with thinner struts had a comparable recanalization and embolism rate, while a lower retraction force had to be applied compared to the prototype with thicker struts. Conclusion Complete wall-stent apposition facilitates a higher recanalization rate and lower embolism rate but also correlates to a higher necessary retraction force and thus possibly higher risk of endothelium damage. Stent modifications leading to a reduced retraction force do not compromise efficacy and embolism rate. Key Points:  Citation Format


2018 ◽  
Vol 10 (Suppl 1) ◽  
pp. i4-i7 ◽  
Author(s):  
Aquilla S Turk ◽  
Don Frei ◽  
David Fiorella ◽  
J Mocco ◽  
Blaise Baxter ◽  
...  

BackgroundThe development of new revascularization devices has improved recanalization rates and time, but not clinical outcomes. We report a prospectively collected clinical experience with a new technique utilizing a direct aspiration first pass technique with large bore aspiration catheter as the primary method for vessel recanalization.Methods98 prospectively identified acute ischemic stroke patients with 100 occluded large cerebral vessels at six institutions were included in the study. The ADAPT technique was utilized in all patients. Procedural and clinical data were captured for analysis.ResultsThe aspiration component of the ADAPT technique alone was successful in achieving Thrombolysis in Cerebral Infarction (TICI) 2b or 3 revascularization in 78% of cases. The additional use of stent retrievers improved the TICI 2b/3 revascularization rate to 95%. The average time from groin puncture to at least TICI 2b recanalization was 37 min. A 5MAX demonstrated similar success to a 5MAX ACE in achieving TICI 2b/3 revascularization alone (75% vs 82%, p=0.43). Patients presented with an admitting median National Institutes of Health Stroke Scale (NIHSS) score of 17.0 (12.0–21.0) and improved to a median NIHSS score at discharge of 7.3 (1.0–11.0). Ninety day functional outcomes were 40% (modified Rankin Scale (mRS) 0–2) and 20% (mRS 6). There were two procedural complications and no symptomatic intracerebral hemorrhages.DiscussionThe ADAPT technique is a fast, safe, simple, and effective method that has facilitated our approach to acute ischemic stroke thrombectomy by utilizing the latest generation of large bore aspiration catheters to achieve previously unparalleled angiographic outcomes.


2017 ◽  
Vol 23 (3) ◽  
pp. 279-284 ◽  
Author(s):  
Waleed Brinjikji ◽  
Gregory Michalak ◽  
Ramanathan Kadirvel ◽  
Daying Dai ◽  
Michael Gilvarry ◽  
...  

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.


2021 ◽  
pp. neurintsurg-2020-017042
Author(s):  
Waleed Brinjikji ◽  
Eytan Raz ◽  
Reade De Leacy ◽  
Dan Meila ◽  
Maxim Mokin ◽  
...  

BackgroundOver the past several years there has been increased interest in the use of the Sofia aspiration system (MicroVention, Tustin, California) as a primary aspiration catheter.ObjectiveTo perform a multicenter retrospective study examining the efficacy of the Sofia aspiration catheter as a standalone aspiration treatment for large vessel occlusion.MethodsConsecutive cases in which the Sofia catheter was used for aspiration thrombectomy for large vessel occlusion were included. Exclusion criteria were the following: (1) Sofia not used for first pass, and (2) a stent retriever used as an adjunct on the first pass. The primary outcome of the study was first pass recanalization (Thrombolysis in Cerebral Infarction (TICI) 2c/3). Secondary outcomes included first pass TICI 2b/3, crossover to other thrombectomy devices, number of passes, time from puncture to recanalization, and complications.Results323 patients were included. First pass TICI 2c/3 was achieved in 49.8% of cases (161/323). First pass TICI 2b/3 was achieved in 69.7% (225/323) of cases. 74.8% had TICI 2b/3 with the Sofia alone. Crossover to other thrombectomy devices occurred in 29.1% of cases (94/323). The median number of passes was 1 (IQR=1–3). Median time from puncture to recanalization was 26 min (IQR=17–45). Procedure related complications occurred in 3.1% (10/323) of cases.ConclusionOur study highlights the potential advantage of the Sofia aspiration catheter for primary aspiration thrombectomy in acute ischemic stroke. High rates of first pass recanalization with low crossover rates to other thrombectomy devices were achieved. Median procedure time was low, as were procedural complications.


2017 ◽  
Vol 75 (7) ◽  
pp. 412-418 ◽  
Author(s):  
Luís Henrique de Castro-Afonso ◽  
Guilherme Seizem Nakiri ◽  
Lucas Moretti Monsignore ◽  
Pedro Telles Cougo-Pinto ◽  
Francisco Antunes Dias ◽  
...  

ABSTRACT Mechanical thrombectomy using stent retrievers is the standard treatment for acute ischemic stroke that results from large vessel occlusions. The direct aspiration first pass technique (ADAPT) has been proposed as an efficient, fast, and cost-effective thrombectomy strategy. The aim of this study was to assess the safety and efficacy of ADAPT. Methods Recanalization was assessed using the modified thrombolysis in cerebral infarction (mTICI) score. Neurological outcomes were assessed using the National Institutes of Health Stroke Scale and modified Rankin Scale. Results Fifteen patients were evaluated. The mTICI score was 2b-3 in 80%, and it was 3 in 60% of patients. No intracranial hemorrhage was seen. At three months, modified Rankin Scale scores ≤ 2 were observed in 60% of patients and the mortality rate was 13.3%. Conclusions The ADAPT appears to be a safe, effective, and fast recanalization strategy for treatment of acute ischemic stroke resulting from large vessel occlusions.


2018 ◽  
Vol 7 (6) ◽  
pp. 327-333 ◽  
Author(s):  
Mohamed S. Teleb

Background: Treatment of large vessel occlusion acute ischemic stroke with mechanical thrombectomy has become the standard of care after recent clinical trials. However, the degree of recanalization with stent retrievers remains very important in overall outcomes. We sought to review the utility of a new balloon guide catheter (BGC) in improving the degree of recanalization in conjunction with mechanical thrombectomy. Methods: The medical records of a prospectively collected endovascular ischemic stroke database were reviewed. All consecutive strokes when a FlowGate BGC was used with a thrombectomy stent retriever were identified. Use of a FlowGate BGC, number of passes, final Thrombolysis in Cerebral Infarction (TICI) score, trackability, and use of adjunct devices were all collected and analyzed. Results: Use of a FlowGate BGC resulted in 64% (33/52) first-pass effect (FPE) of TICI 2b/3, and specifically 46% (24/52) TICI 3 FPE (true FPE). A total of 52/62 (84%) of thrombectomy cases were treated with BGCs. In the remaining 10, the BGC was not inflated or used due to the clot not being visualized or the lesions being distal and BGC use thus not deemed appropriate. Adjunct use of an aspiration catheter was seen in 12% (6/52) of cases. The overall success with FlowGate BGCs with one or more passes of TICI 2b/3 was 94% (49/52). Trackability was achieved in 92% (57/62) of cases. Conclusions: Use of the FlowGate BGC as an adjunct to mechanical thrombectomy was associated with good FPE and an overall recanalization of TICI 2b/3 of 94%.


2021 ◽  
pp. 159101992110191
Author(s):  
Orkun Sarioglu ◽  
Fatma C Sarioglu ◽  
Ahmet E Capar ◽  
Demet FB Sokmez ◽  
Berna D Mete ◽  
...  

Purpose Our aim was to evaluate the performance of clot-based radiomics features (RFs) for predicting first pass effect (FPE) in patients with acute ischemic stroke (AIS). The secondary purpose was to search for any other variables associated with FPE. Materials and methods Patients who underwent mechanical thrombectomy (MT) for anterior circulation large vessel stroke in a single center were retrospectively reviewed. Patients were divided into two groups: FPE and non-FPE. Two observers extracted RFs from the clot on pretreatment noncontrast computed tomography (NCCT) images. Demographic, clinical, periprocedural, and RFs were compared between the groups and receiver operating characteristic (ROC) curves were constructed. Logistic regression analysis was used to determine the independent predictors of FPE. Results Fifty-two patients (27 female, 25 male; mean age 64.50 ± 15.15) who were treated by stent retrievers as the first option were included in the study. FPE was achieved in 25 patients (25/52, 48.1%). Twelve RFs were significantly different between patients with FPE and non-FPE. The long-run low gray-level emphasis (odds ratio = 44.24, p = 0.003) and the zone percentage (odds ratio = 16.88, p = 0.017) were found as independent predictors of FPE. Female sex and a baseline ASPECT score of >8.5 were the other independent variables to predict FPE. The diagnostic accuracy to predict FPE was observed as 83% when using all independent predictors in our predictive model. Conclusions Clot-based RFs on NCCT may help to estimate the success of the intended outcome of MT in patients with AIS.


2021 ◽  
Vol 12 ◽  
Author(s):  
Takeshi Yoshimoto ◽  
Kanta Tanaka ◽  
Junpei Koge ◽  
Masayuki Shiozawa ◽  
Hiroshi Yamagami ◽  
...  

Introduction: The usefulness of the blind exchange with mini-pinning (BEMP) technique has recently been reported for mechanical thrombectomy in patients with stroke owing to medium vessel occlusion (MeVO). The Tron stent retriever can be delivered and deployed through a 0.0165-inch microcatheter. This retriever has potential as an effective and safe treatment for acute ischemic stroke (AIS) due to occlusion of the M2 segment of the middle cerebral artery (MCA). Here, we report the outcomes of the BEMP technique using Tron stent retrievers for M2 occlusion thrombectomy.Methods: Consecutive patients with AIS owing to M2 occlusion who underwent the BEMP technique using 2 × 15-mm or 4 × 20-mm Tron stent retrievers were included. The technique involves deploying a Tron stent retriever through a 0.0165-inch microcatheter, followed by microcatheter removal and blind navigation of a 3MAX or 4MAX aspiration catheter over the bare Tron delivery wire until the aspiration catheter reaches the clot. A Tron stent retriever is inserted into the aspiration catheter like a cork and subsequently pulled as a unit. We assessed procedural outcomes [first-pass expanded thrombolysis in cerebral infarction (eTICI) score 2c/3 and 2b/2c/3], safety outcomes [symptomatic intracranial hemorrhage (sICH)], and clinical outcomes (good outcome rate defined as modified Rankin Scale score 0–2 at 90 days and mortality at 90 days).Results: Eighteen M2 vessels were treated in 15 patients (six female, median age: 80 years, and median National Institutes of Health Stroke Scale score: 18). The BEMP technique was performed successfully in all cases. Whether to use a 3MAX or 4MAX catheter was determined by considering one of the following target vessels: dominant, non-dominant, or co-dominant M2 (3MAX, n = 9; 4MAX, n = 9). The first-pass eTICI 2c/3 and 2b/2c/3 rates were 47 (7/15) and 60% (9/15), respectively; sICH was not observed. Seven patients (47%) achieved good outcomes, and one patient (7%) died within 90 days.Conclusions: The Tron stent retriever was safely and effectively used in the BEMP technique for acute MCA M2 occlusion and can be combined with a 0.0165-inch microcatheter, which may be useful for treating MeVO, in general.


2019 ◽  
Vol 12 (9) ◽  
pp. 853-857 ◽  
Author(s):  
Sarah Johnson ◽  
Juyu Chueh ◽  
Matthew J Gounis ◽  
Ray McCarthy ◽  
J Patrick McGarry ◽  
...  

BackgroundClot mechanical properties are influenced by composition and the arrangement of components within the clot. This work investigates the effects of platelet-driven contraction on blood clot microstructure and mechanical behavior, and provides insight into some implications for mechanical thrombectomy.MethodsPlatelet-contracted clot analogues (PCCs) and non-contracted clot analogues (NCCs) were prepared from blood mixtures of various hematocrits (%H), that is, the volume percentage of red blood cells (RBCs) in the mixture. Mechanical testing was performed to compare the behavior of the analogues with previously tested human thromboemboli. Scanning electron microscopy and histology investigated the clot microstructure and composition. The association between clot properties and their behavior during mechanical behavior was also investigated.ResultsOverall, PCCs were found to be stiffer than NCCs, across all hematocrits. PCCs with a low %H resisted complete ingestion via contact aspiration alone or complete retrieval with stent-retrievers. PCCs with a higher %H and all NCCs were fully retrievable, although the likelihood of fragmentation was increased in clots with a greater %H. Histologically, there was little difference in the RBC and fibrin content between PCCs and NCCs with the same %H. However, the microstructure of the two groups differed significantly.ConclusionA selection of repeatable clot analogues with a range of mechanical properties have been developed for in vitro modeling of acute ischemic stroke. Platelet contraction significantly affects clot volume and microstructure, and in turn clot stiffness. The significant difference in mechanical properties and microstructure, but without an appreciable difference in histology, implies that histological studies of explanted human clots alone may not prove to be predictive of the mechanical behavior of the clots in thrombectomy.


Sign in / Sign up

Export Citation Format

Share Document