Influence of distortion factor of induced voltage in B-coil on magnetic property measured with a single sheet tester

2019 ◽  
Vol 61 ◽  
pp. S39-S48
Author(s):  
Takuya Shibataki ◽  
Yasuhito Takahashi ◽  
Koji Fujiwara
2014 ◽  
Vol 679 ◽  
pp. 241-246
Author(s):  
Dina Maizana ◽  
Y. Yanawati ◽  
A. Nazifah

– This paper presents the comparison induced voltage between 0.35 mm and 0.50 mm thicknesses 3% SiFe (NG) with different frequency which are 45 Hz, 50 Hz and 60 Hz by using Single Sheet Tester (SST). This experiment used to measure the search coil voltage L1N1 and L2N2 at two positions (1st position and 2nd position) and harmonic content. The analysis shows, at different frequency for both thicknesses, the value of search coil voltage L1N1 is higher than the search coil voltage L2N2 for both positions. It shows the easy direction is single sheet tester direction at the 1st position for 0.35 mm and 0.50 mm thickness with different frequency. For harmonic content, at 0.6 T with different frequency for both thicknesses, the 3rd order harmonic factor of 0.35 mm is lower than 0.50 mm thickness 3% SiFe (NG). It is because the higher losses can increase the harmonic of the materials. It means that harmonic is affected by ingredient and thicknesses in core material.


1979 ◽  
Author(s):  
H Nagata ◽  
T Seya ◽  
Y Oguma ◽  
M Yamauchi ◽  
T Murakoshi ◽  
...  

We have studied the ultrastructures of tissue thromboplastin (T.Tbp) to demonstrate how It changes during coagulation.[Materials and Methods] T.Tbp from lungs of rabbits was used for these studies. It was injected into ear veins of rabbits. Lungs were resected at several seconds, 10sec, 1 min, 5 min, 24 hrs or 48 hrs after the injection. They were examined by transmission electron microscope.[Results] Concentrically arranged membrane structures of the injected T.Tbp disappeared in extremely short time after the injection. 1 min after the injection, fibrin fibers were seen between single sheet of membrane and endothelial cells of capillaries. In the rabbit which had died suddenly after the injection of T.Tbp, multiple pulmonary thrombi made of fibrin and platelets were seen in capillaries. The endothelial cells of capillaries were destroyed and interstitial tissues were edematous.The hypercoagulable state was seen 10~30sec after the start of the injection, indicating the shortening of r of TEG. Then, it gradually returned the level before injection. Moreover, changes of the measurements of fibrinogen, antiplasmin and prekallikrein were also seen after the injection.


2017 ◽  
Author(s):  
yongson hong ◽  
O Pong-Sik ◽  
Ryang Se-Hun ◽  
Sin Kum-Chol ◽  
Ri Un-Byol

In this paper, we considered fabrication of Fe nanowires by AAO template, magnetic property, and influences (fabrication voltage of template, temperature, deposition time, and deposition voltage) on them. <br>


Author(s):  
Fubin Zhang ◽  
David Maxwell

Abstract Based on the understanding of laser based techniques’ physics theory and the topology/structure of analog circuit systems with feedback loops, the propagation of laser induced voltage/current alteration inside the analog IC is evaluated. A setup connection scheme is proposed to monitor this voltage/current alteration to achieve a better success rate in finding the fail site or defect. Finally, a case of successful isolation of a high resistance via on an analog device is presented.


2009 ◽  
Vol 25 (1) ◽  
pp. 77-82 ◽  
Author(s):  
Xiao-Na JIANG ◽  
Zhong-Wen LAN ◽  
Zhong YU ◽  
Ya-Ming Zhuang ◽  
Pei-Yuan LIU
Keyword(s):  

2017 ◽  
Vol 68 (3) ◽  
pp. 581-585 ◽  
Author(s):  
Gabriela Oprina ◽  
Ladislau Radermacher ◽  
Daniel Lingvay ◽  
Dorian Marin ◽  
Andreea Voina ◽  
...  

The corrosion state of an underground metallic pipeline of �161 mm and 565 m length was assessed by specific electrical and electrochemical measurements. The investigated pipe, buried in 1997, was protected against corrosion by successive layers of bituminous material with a total thickness of 1 to 1.2 mm. The pipeline crosses three electrified railway lines (50 Hz - 28 kV), and then its route is approximately parallel to these lines; thus, the induced AC voltages between line and ground were calculated obtaining values between 4.05 and 7.1 Vrms, in good agreement with the values measured in the accessible points. The measurements regarding the insulation capacity against corrosion of the bituminous insulation, performed at one month and after 19 years of burial, showed an increase of the average cathode current density needed for obtaining the protection potential in the range �1.00 � �1.28 VCu/CuSO4 of approx. three times (from 6.65 up to 19.96 mA/m2), in good agreement with the evolution of the insulation resistance measured between the steel pipe (having a contact area with the ground of 270.5 m2) and a ground socket of 4 W, which decreased from 995 to 315 kW. Following the analysis and processing of the field collected data, it is considered that, by implementing a cheap cathodic protection system (without cathodic current power supply), based on the rectification of the AC induced voltage, the safe operation period of the investigated pipeline may be extended by at least 50 years.


Author(s):  
Simon Nicholls ◽  
Michael Pushkin ◽  
Vladimir Ashkenazy

[120]A single sheet, written at the age of about sixteen. Was in the ‘grandmother’s’ copy of the Gospels.God in the general meaning of this word is the cause of the totality of phenomena.Jesus Christ speaks of God in a particular meaning of this word, of God as the inexplicable cause which has given rise to the doctrine of morality. Since the concept of morality is ...


Sign in / Sign up

Export Citation Format

Share Document