harmonic content
Recently Published Documents


TOTAL DOCUMENTS

342
(FIVE YEARS 75)

H-INDEX

26
(FIVE YEARS 2)

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 519
Author(s):  
Zhonghuan Su ◽  
Longfu Luo ◽  
Jun Liu ◽  
Zhongxiang Li ◽  
Hu Luo ◽  
...  

Since the transmission distance of submarine cable transmission is inversely proportional to the input frequency, to solve the problem of large losses in the transmission process of offshore wind power, this paper proposes a three-frequency transformer which enables the output of 50 Hz at the input of 50/3 Hz excitation. In this paper, the magnetic flux of a three-dimensional wound core transformer is analytically modeled, the existing condition of magnetic flux harmonics of a three-dimensional wound core transformer is analyzed, the distribution of harmonic content in magnetic flux is obtained, and the principle of realizing frequency conversion is expounded. Secondly, the finite element analysis of the frequency converter is carried out. Finally, a prototype of a frequency transformer is made and tested to verify the correctness of the proposed scheme.


Author(s):  
Tatyana Anisimova ◽  
Anastasiya Danilina ◽  
Vadim Volkov ◽  
Vasily Kryuchkov
Keyword(s):  

Electronics ◽  
2021 ◽  
Vol 10 (19) ◽  
pp. 2411
Author(s):  
Sajjad Ahmadi ◽  
Philippe Poure ◽  
Davood Arab Khaburi ◽  
Shahrokh Saadate

In this paper, a five-level neutral-point-clamped (NPC) inverter with short-circuit fault-tolerant capability is presented. Based on the proposed approach, in order to ensure service continuity subsequent to a short-circuit fault event in a switch, two steps are carried out. First of all, destructive consequences arising from short-circuit fault in a power switch is prevented. Afterwards, according to the defected component, remedial actions are taken. The proposed strategy does not require any redundant component. The service continuity is acquired by applying a remedial control and modifying switching commands applied to the power switches. Using the proposed approach helps to restore the rated voltage and rated current at the terminal, and there is no limit for modulation index during fault-tolerant operation under remedial control. Furthermore, compared to healthy operation, harmonic content of the terminal voltage and current is not deteriorated during fault-tolerant operation. Moreover, additional components, such as bidirectional switches and contactors, are not employed in this strategy. Only some fast fuses are placed in the converter circuit for protection purposes which do not impose a noticeable cost compared to the bidirectional switches and contactors.


2021 ◽  
Vol 12 (2) ◽  
pp. 913-922
Author(s):  
Hao Li ◽  
Jahangir Rastegar ◽  
Baosheng Wang

Abstract. In high-speed and high-precision machinery, trajectories with high-frequency harmonic content are one of the main sources of reduction of operational precision. Trajectories with high-frequency harmonic content generally demand even higher-harmonic actuating forces/torques due to the nonlinear dynamics of such systems, which may excite natural modes of vibration of the system and/or be beyond the dynamic response limitation of the actuation devices. In this paper, a global interpolation algorithm that uses the trajectory pattern method (TPM) for synthesizing low-harmonic trajectories is presented. The trajectory synthesis with the TPM is performed with a prescribed fundamental frequency and continuous jounce boundary condition, which would minimize the number of high-harmonic components in the required actuation forces/torques and avoid excitation of the system modes of vibration. The minimal curvature variation energy method, Lagrange multiplier method, and contour error control are used to obtain smooth kinematic profiles and satisfy the trajectory accuracy requirements. As an example, trajectory patterns that consist of a fundamental frequency sinusoidal time function and its first three harmonics are used to synthesize the desired trajectories for a selected dynamic system. The synthesized trajectories are shown to cause minimal system vibration during its operation. A comparison with a commonly used trajectory synthesis method clearly shows the superiority of the developed TPM-based approach in reducing vibration and demand on the actuator dynamic response, thereby allowing the system to operate at higher speeds and precision.


2021 ◽  
Vol 12 ◽  
Author(s):  
Meysam Asgari ◽  
Liu Chen ◽  
Eric Fombonne

The presence of prosodic anomalies in autistic is recognized by experienced clinicians but their quantitative analysis is a cumbersome task beyond the scope of typical pen and pencil assessment. This paper proposes an automatic approach allowing to tease apart various aspects of prosodic abnormalities and to translate them into fine-grained, automated, and quantifiable measurements. Using a harmonic model (HM) of voiced signal, we isolated the harmonic content of speech and computed a set of quantities related to harmonic content. Employing these measures, along with standard speech measures such as loudness, we successfully trained machine learning models for distinguishing individuals with autism from those with typical development (TD). We evaluated our models empirically on a task of detecting autism on a sample of 118 youth (90 diagnosed with autism and 28 controls; mean age: 10.9 years) and demonstrated that these models perform significantly better than a chance model. Voice and speech analyses could be incorporated as novel outcome measures for treatment research and used for early detection of autism in preverbal infants or toddlers at risk of autism.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4021
Author(s):  
Jorge Luiz Moreira Pereira ◽  
Adonis Ferreira Raiol Leal ◽  
Gabriel Oliveira de Almeida ◽  
Maria Emília de Lima Tostes

The growth in global electricity demand has expanded the search for new energy resources. Renewable sources such as photovoltaic (PV) systems have proven to be major alternatives. PV generators connected to distribution grids have exhibited significant growth in the last decade, so it is essential to analyse the impacts resulting from this increase. This work investigated the influence of high PV system penetration in distribution grids in terms of harmonic levels. In particular, this study addressed the distortions in voltage and current waveforms in the presence and absence of PV generators connected to a distribution grid. Additionally, the total harmonic content and the individual harmonic frequencies of voltage and current were analysed. This study was performed with an IEEE 37 bus distribution system and the Open Distribution System Simulator software (OpenDSS). The results show that the voltage limits of some phases far away from a substation can exceed the limits. Furthermore, the total harmonic distortion (THD) and individual harmonic distortion (IHD) levels for voltage and current were significantly high for harmonics of the 3rd, 5th, and 7th orders, where current levels violate the standard levels.


Author(s):  
S. Venkatesh

Our project mainly focuses work a lot being carried out in the field of distributed generation. For the electric grid, so Many distributed generation systems are being made. At this time when the non-renewable sources of energy such as oil, coal, etc are very fast disappearing, a study of distributed generation systems (DGs) and Establishing of such systems using renewable sources of energy becomes very important. we have seen several major problems will happen, when harmonic content of the current is flows into the grid, like this issue several issues are going to meet. When a Distribution Generation source is being linked to the grid. “The current being injected should have harmonic content conforming to standards such as IEEE 512-1992”[1].To limit the harmonic current injected into the grid. The hardware is tailor-made to be used for a solar PV panels based distributed generation system. This project deals mainly with Establishing the hardware for a grid connected inverter. This means that a proper plan of action should be present in the required system, special type of filters are made to abolish higher order harmonics, this is only the reason why filters would be less bulky and cheap. only the higher order harmonics are decreased by specially made filters, Lower order harmonics are attenuated by a technique called “an adaptive harmonic elimination technique (AHE). In our project we need to develop several blocks called the inverter hardware, design and implementation of closed loop control, transformer, the filters along with adaptive selective harmonic elimination scheme


2021 ◽  
Vol 11 (13) ◽  
pp. 6058
Author(s):  
Georgia Paraskaki ◽  
Sven Ackermann ◽  
Bart Faatz ◽  
Gianluca Geloni ◽  
Tino Lang ◽  
...  

Current FEL development efforts aim at improving the control of coherence at high repetition rate while keeping the wavelength tunability. Seeding schemes, like HGHG and EEHG, allow for the generation of fully coherent FEL pulses, but the powerful external seed laser required limits the repetition rate that can be achieved. In turn, this impacts the average brightness and the amount of statistics that experiments can do. In order to solve this issue, here we take a unique approach and discuss the use of one or more optical cavities to seed the electron bunches accelerated in a superconducting linac to modulate their energy. Like standard seeding schemes, the cavity is followed by a dispersive section, which manipulates the longitudinal phase space of the electron bunches, inducing longitudinal density modulations with high harmonic content that undergo the FEL process in an amplifier placed downstream. We will discuss technical requirements for implementing these setups and their operation range based on numerical simulations.


Sign in / Sign up

Export Citation Format

Share Document