scholarly journals Direct Fluorescent Antibody Test

2020 ◽  
Author(s):  
2017 ◽  
Vol 9 (01) ◽  
pp. 053-056 ◽  
Author(s):  
Vrushali Patwardhan ◽  
Preena Bhalla ◽  
Deepti Rawat ◽  
Vijay Kumar Garg ◽  
Kabir Sardana ◽  
...  

ABSTRACT Objective: To compare laboratory tests that can simultaneously detect and type herpes simplex virus (HSV) directly from the genital ulcer specimens in clinically suspected cases of genital herpes. Materials and Methods: A study was conducted over 10 months and 44 adult male and female patients clinically suspected with genital herpes were recruited. Genital ulcer swab specimens were subjected to glycoprotein-G gene-based conventional polymerase chain reaction (PCR) and commercially available direct fluorescent antibody (DFA) test and the results were compared. Results: PCR for HSV was positive in 82% (36/44) cases. DFA was positive in 68.2% (30/44) cases. There was 100% agreement between HSV types detected by DFA and PCR. The strength of agreement between the results was better in primary genital herpes than recurrent cases. Conclusion: PCR was found to be better in the detection of HSV in recurrent genital herpes patients. It is a better modality, especially when genital herpes clinically presents with ulcerative or crusted lesions, and is also a cheaper alternative as compared to DFA.