scholarly journals Determination of Five Phthalate Esters and Bisphenol A in Fruit Juice by Packed-nanofiber Solid Phase Extraction Coupled with Gas Chromatography

2019 ◽  
Vol 8 (1) ◽  
pp. 50-54 ◽  
Author(s):  
Zigang Tang ◽  
Tao Kang ◽  
Xuejun Kang

Packed-nanofiber solid phase extraction   (PFSPE) combined with gas chromatography-flame ionization detector (GC-FID) was developed for the simultaneous determination of five phthalate esters (PAEs) and bisphenol A (BPA) in fruit juice. The PAEs and BPA was concentrated by PFSPE using polystyrene- pyridine (PS-PD) nanofibers as the sorbent, followed determined by GC-FID. Under this modified procedure, satisfied recoveries in fruit juice sample ranging from 81.9% to 109.6% were obtained. And relative standard deviation values (RSD) were ranged from 1.9 % to 9.8% in orange juice sample. The limits of detection (LOD) and the limits of quantification (LOQ) of five PAEs and BPA were ranged from 0.02 μg/mL to 0.30 μg/mL and 0.06 μg/L to 1.10 μg/L, respectively. This established method was successfully applied to detect real fruit juice samples, which were collected in local supermarket. These results demonstrated the applicability of the established PFSPE-based extraction coupled with gas chromatography method for determination of PAEs and BPA in fruit juice products.

2020 ◽  
Vol 165 ◽  
pp. 03044
Author(s):  
Liangliang Tian ◽  
Yongfu Shi ◽  
Dongmei Huang ◽  
Huijuan Yu ◽  
Shuai Wang ◽  
...  

In this study, a special method was developed for the determination of 7 kinds of polychlorinated biphenyls (PCBs) residues in dried kelp by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/dichloromethane (1/1, v/v) by ultrasonic extraction. Clean-up methods were used by concentrated sulphuric acid, neutral alumina oxide solid phase extraction cartridge and silica solid phase extraction cartridge. The analytical compounds were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5~200ng/mL, and the correlation coefficients were 0.9993~0.9998. The limit of quantification (LOQ) for target analytical compounds ranged from 6.0 to 7.5μg/kg. At the spiked levels of 10,20,50 μg/kg,the average recoveries ranged from 81.8% to 105% with the relative standard deviations 3.05%~11.2%. The result showed that the proposed method was accurate and could be used for the determination of the PCBs in dried kelp.


Sign in / Sign up

Export Citation Format

Share Document