scholarly journals Average Absorbed Breast Dose (2ABD) to Mean Glandular Dose (MGD) Conversion Function for Digital Breast Tomosynthesis: A New Approach

2021 ◽  
pp. 183-191
Author(s):  
‪Raffaele M Tucciariello ◽  
Rocco Lamastra ◽  
Patrizio Barca ◽  
Marine Evelina Fantacci ◽  
Antonio C Traino

Background: In this work a new method for the Mean Glandular Dose evaluation in digital breast tomosynthesis (DBT) is presented. Methods: Starting from the experimental-based dosimetric index, 2ABD, which represents the average absorbed breast dose, the mean glandular dose MGD2ABD was calculated using a conversion function of glandularity f(G), obtained through the use of Monte Carlo simulations.Results: f(G) was computed for a 4.5 cm thick breast: from its value MGD2ABD for different compressed breast thicknesses and glandularities was obtained. The comparison between MGD2ABD estimates and the dosimetric index provided in the current dosimetry protocols, following the Dance's approach, MGDDance, showed a good agreement (<10%) for all the analyzed breast thicknesses and glandularities. Conclusion: The strength of the proposed method can be considered an accurate mean glandular dose assessment starting from few and accessible parameters, reported in the header DICOM of each DBT exam.

2015 ◽  
Vol 42 (7) ◽  
pp. 3788-3800 ◽  
Author(s):  
Mariana Baptista ◽  
Salvatore Di Maria ◽  
Sílvia Barros ◽  
Catarina Figueira ◽  
Marta Sarmento ◽  
...  

2016 ◽  
Vol 32 ◽  
pp. 326
Author(s):  
E. Tzamicha ◽  
A. Dimitriadis ◽  
H. Gonis ◽  
E. Georgiou ◽  
V. Tsapaki ◽  
...  

2014 ◽  
Vol 104 ◽  
pp. 158-162 ◽  
Author(s):  
M. Baptista ◽  
S. Di Maria ◽  
N. Oliveira ◽  
N. Matela ◽  
L. Janeiro ◽  
...  

Author(s):  
Leandro Barbosa da Silveira Gatto ◽  
Delson Braz ◽  
Leonardo Pacifico ◽  
Paulo Travassos ◽  
Luis Alexandre Goncalves Magalhaes

Abstract Digital breast tomosynthesis (DBT) is a screening and diagnostic modality that acquires images of a breast at multiple angles during a short scan. The Selenia Dimensions (Hologic, Bedford, Mass) DBT system can perform both full-field digital mammography and DBT. The system acquires 25 projections over a 15° angular range (from −7.5° to +7.5°). X-ray spectroscopy is generally linked with a high-resolution semiconductor detector through a correction to its energy response function. The energy spectrum describes the radiation field, in which several quality parameters can be extracted, such as the effective energy, half-value layer and exposure. X-ray spectroscopy is usually performed with solid-state semiconductor detectors. Radiation dose is a concern in mammography, as the current protocols recommend that medical physicians evaluate mean glandular dose (MGD) as a part of service quality control. Studies are needed for radiation dose optimization from tomosynthesis patients. The COMET metrological X-ray tube, considered as with a constant potential and cooled, has proved to be a crucial tool in order to obtain the high energy resolution for low-energy radiographs in mammography. The Monte Carlo method, through Monte Carlo N-Particle eXtended (MCNPX), was proven to be an essential tool for image formation and posterior analysis of the deposited dose from breast simulators and radiographic contrast evaluation, for several anode/filter combinations. The purpose of this work was to assess the MGD and spectra in slabs of polymethyl methacrylate (PMMA) and breast equivalent thicknesses using four experiments with a Hologic Selenia Dimensions mammography X-ray tube with multimeter, a spectrometer (only for spectra, in this case), a metrological X-ray tube with a multimeter, and the MCNPX code. References indicate that the real conditions for a mammography X-ray tube that conducts tomosynthesis include tube voltages of 26, 29, 30 and 33 kVp. Taking into account several thicknesses of PMMA, both the MGD and spectral results were in accordance with the references. Most of the spectra were in accordance with the references, showing that the resources used in the experiments can evaluate the energy level received by a patient. The MGD values were lower than those in the references from 30 to 50 mm PMMA, and the data can be used for improvements in the detectors used in the Laboratory of Metrology in the State of Rio de Janeiro University, Brazil. Additionally, in the future, optimization of image quality can be performed for both semiconductors and mammography X-ray equipment.


2018 ◽  
Vol 64 (1) ◽  
pp. 015003
Author(s):  
Christian Fedon ◽  
Carolina Rabin ◽  
Marco Caballo ◽  
Oliver Diaz ◽  
Eloy García ◽  
...  

2011 ◽  
Vol 26 (3) ◽  
pp. 249-253 ◽  
Author(s):  
Vladan Ljubenov ◽  
Rodoljub Simovic

This paper presents the results of research on photon reflection from plane targets based on Monte Carlo simulations performed by the MCNP code. Five materials (water, concrete, aluminum, iron, and copper) are examined in the area of initial photon energies of up to 200 keV. The values of the total number albedo for photons dependent on the initial photon energy or the mean number of photon scatterings are calculated and graphically presented. We have shown that the values of the total number albedo for different target materials, expressed as a function of the mean number of photon scatterings, are in good agreement with each other and can be approximated by simple, universal analytic functions obtained by the least squares method. The accuracy of these analytic appoximations is confirmed by their comparison with the results of PENELOPE and FOTELP Monte Carlo codes.


2011 ◽  
Vol 474-476 ◽  
pp. 565-569
Author(s):  
Xi Feng Qin ◽  
Shuang Li ◽  
Feng Xiang Wang ◽  
Yi Liang

In view of the influence of the projected range, the range straggling, and the lateral deviation of ions in materials on the property of device in the fabrication of photoelectric integration devices by ion implantation, the mean projected ranges and range straggling for energetic 200 – 500 keV Nd ions implanted in 6H-SiC were measured by means of Rutherford backscattering followed by spectrum analysis. The measured values are compared with Monte Carlo code (SRIM2006) calculations. It has been found that the measured values of the mean projected range Rp are good agreement with the SRIM calculated values; for the range straggling △Rp, the difference between the experiment data and the calculated results is much higher than that of Rp


2015 ◽  
Vol 42 (9) ◽  
pp. 5342-5355 ◽  
Author(s):  
Kyungsang Kim ◽  
Taewon Lee ◽  
Younghun Seong ◽  
Jongha Lee ◽  
Kwang Eun Jang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document