scholarly journals Percutaneous Vertebroplasty of the Entire Thoracic and Lumbar Vertebrae for Vertebral Compression Fractures Related to Chronic Glucocorticosteriod Use: Case Report and Review of Literature

2014 ◽  
Vol 15 (6) ◽  
pp. 797 ◽  
Author(s):  
Qing-Hua Tian ◽  
Chun-Gen Wu ◽  
Quan-Ping Xiao ◽  
Cheng-Jian He ◽  
Yi-Feng Gu ◽  
...  
2018 ◽  
Vol 75 (10) ◽  
pp. 1049-1053
Author(s):  
Zoran Aleksic ◽  
Ivana Stankovic ◽  
Ivana Zivanovic-Macuzic ◽  
Dejan Jeremic ◽  
Aleksandar Radunovic ◽  
...  

Introduction. Percutaneous vertebroplasty (PVP), as a mini-invasive approach in the treatment of patients with osteoporotic vertebral compression fractures (OVCFs), provides stabilization of the spine and relives pain. The most commonly it is applied in the 3?6 weeks before bending of the spine. Complete cessation of pain is easier to achieve if you treat ?less mature? fractures. The aim of the report is to show that PVP is effective and safe for old fractures too. Case report. A 77-old patient suffered from a stable compression fracture of 3th lumbar (L3) vertebral body after minor trauma. This fracture was clinically and radiologically diagnosed. The conservative treatment that included lumbo-sacral orthosis (LSO), analgesic drugs and physical therapy, was primarily applied due to permanent pain and type of fracture. After a period of two months, pain persisted, but it was localized in a thoracic spinal segment with radiologically diagnosed fractured bodies of 8th (Th8) and 10th (Th10), thoracic vertebra without neurological deficit. Thoraco-lumbo-sacral orthosis (TLSO) was prescribed and after six months the indication for vertebroplasty of the Th8 and Th10 vertebral body was given. The pain relief had been achieved and the patient was discharged from the Clinic for Orthopedics on the postoperative day 2, and was symptom free during the follow-up period. Conclusion. In patients with stable OVCFs, PVP is an effective therapy for reducing pain and improving mobility of 6 months old fractures.


2021 ◽  
Vol 49 (1) ◽  
pp. 030006052198946
Author(s):  
Xiaoguang Fan ◽  
Sha Li ◽  
Xianshang Zeng ◽  
Weiguang Yu ◽  
Xiangzhen Liu

Objective To explore possible risk factors for poor outcomes following percutaneous vertebroplasty (PV) for painful osteoporotic compression fractures of thoracolumbar vertebra. Methods This was a retrospective review of data from patients who underwent PV at our institution over a ten-year period to evaluate the association between possible risk factors and thoracolumbar pain (T11-L2). According to the difference between pre- and post-operative visual analogue scale (VAS) scores for pain, patients were separated into poor relief (PR; <4) and good relief (GR; ≥4) of pain. Results Of the 750 patients identified, 630 (PR group, n =310; GR group, n = 320) fulfilled the eligibility criteria. Multivariate binary logistic analysis showed that bone mineral density (BMD), >2 fractured vertebral bodies, maldistribution of bone cement, <5 ml bone cement injected into a single vertebral body and thoracolumbar fascia injury prior to surgery were independent risk factors associated with thoracolumbar pain following PV. Conclusion Although prospective controlled studies are required to confirm our results, this review suggests that the above factors should be taken into account when selecting patients for PV.


2021 ◽  
pp. 155335062110624
Author(s):  
Jing Yang ◽  
Penghui Ni ◽  
Lina Zhang ◽  
Zhanxin Lu ◽  
Dapeng Liu ◽  
...  

Background This study aimed to evaluate a personalized 3D-printed percutaneous vertebroplasty positioning module and navigation template based on preoperative CT scan data that was designed to treat patients with vertebral compression fractures caused by osteoporosis. Methods A total of 22 patients with vertebral compression fractures admitted to our hospital were included in the study. Positioning was performed with the new 3D-printed positioning module, and the navigation template was used for patients in the experimental group, and the traditional perspective method was used for patients in the control group. The experimental group consisted of 11 patients, 2 males and 9 females, with a mean age of 67.27 ± 11.86 years (range: 48 to 80 years), and the control group consisted of 11 patients, 3 males and 8 females, with a mean age of 74.27 ± 7.24 years (range: 63 to 89 years). The puncture positioning duration, number of intraoperative fluoroscopy sessions, and preoperative and postoperative visual analog scale (VAS) scores were statistically analyzed in both groups. Results The experimental group had shorter puncture positioning durations and fewer intraoperative fluoroscopy sessions than the control group, and the differences were statistically significant (P < .05). There were no significant differences in age or preoperative or postoperative VAS scores between the two groups (P > .05). Conclusions The new 3D-printed vertebroplasty positioning module and navigation template shortened the operation time and reduced the number of intraoperative fluoroscopy sessions. It also reduced the difficulty in performing percutaneous vertebroplasty and influenced the learning curve of senior doctors learning this operation to a certain degree.


2002 ◽  
Vol 96 (1) ◽  
pp. 56-61 ◽  
Author(s):  
Kyung Sik Ryu ◽  
Chun Kun Park ◽  
Moon Chan Kim ◽  
Joon Ki Kang

Object. The use of polymethylmethacrylate (PMMA) cement by percutaneous injection in cases requiring vertebroplasty provides pain relief in the treatment of osteoporotic vertebral compression fractures. A retrospective study was performed to assess what caused PMMA cement to leak into the epidural space and to determine if this leakage caused any changes in its therapeutic benefits. Methods. Polymethylmethacrylate was injected into 347 vertebral compression fractures in 159 patients. The cement leaked into the epidural space in 92 (26.5%) of 347 treated vertebrae in 64 (40.3%) of the 159 patients, as demonstrated on postoperative computerized tomography scanning. Epidural leakage of PMMA cement occurred more often when injected above the level of T-7 (p = 0.001) than below. The larger the volume of PMMA injected the higher the incidence of epidural leakage (p = 0.03). Using an injector also increased epidural leakage (p = 0.045). The position of the needle tip within the vertebral body and the pattern of venous drainage did not affect epidural leakage of the cement. Leakage of PMMA into the epidural space reduced the pain relief expected after vertebroplasty. The immediate postoperative visual analog scale scores were higher (and therefore reflective of less pain relief) in patients in whom epidural PMMA leakage occurred (p = 0.009). Three months postoperatively, the authors found the highest number of patients presenting with pain relief, including those in the group with epidural leakage, and at this follow-up stage there were no significant differences between the two groups. Conclusions. The authors found that epidural leakage of PMMA after percutaneous vertebroplasty was dose dependent. The larger amount of injected PMMA, the higher the incidence of leakage. Injecting vertebral levels above T-7 also increased the incidence of epidural leakage. Epidural leakage of PMMA may attenuate only the immediate therapeutic effects of vertebroplasty.


Sign in / Sign up

Export Citation Format

Share Document