scholarly journals Changes Over Time of Diffusion MRI in the White Matter of Aging Brain, a Good Predictor of Verbal Recall

2020 ◽  
Vol 12 ◽  
Author(s):  
Renaud Nicolas ◽  
Bassem Hiba ◽  
Bixente Dilharreguy ◽  
Elodie Barse ◽  
Marion Baillet ◽  
...  
2018 ◽  
Vol 2 (1) ◽  
pp. 86-105 ◽  
Author(s):  
Michael A. Powell ◽  
Javier O. Garcia ◽  
Fang-Cheng Yeh ◽  
Jean M. Vettel ◽  
Timothy Verstynen

The unique architecture of the human connectome is defined initially by genetics and subsequently sculpted over time with experience. Thus, similarities in predisposition and experience that lead to similarities in social, biological, and cognitive attributes should also be reflected in the local architecture of white matter fascicles. Here we employ a method known as local connectome fingerprinting that uses diffusion MRI to measure the fiber-wise characteristics of macroscopic white matter pathways throughout the brain. This fingerprinting approach was applied to a large sample ( N = 841) of subjects from the Human Connectome Project, revealing a reliable degree of between-subject correlation in the local connectome fingerprints, with a relatively complex, low-dimensional substructure. Using a cross-validated, high-dimensional regression analysis approach, we derived local connectome phenotype (LCP) maps that could reliably predict a subset of subject attributes measured, including demographic, health, and cognitive measures. These LCP maps were highly specific to the attribute being predicted but also sensitive to correlations between attributes. Collectively, these results indicate that the local architecture of white matter fascicles reflects a meaningful portion of the variability shared between subjects along several dimensions.


2014 ◽  
Vol 10 ◽  
pp. P701-P702
Author(s):  
Lotte Cremers ◽  
Marius de Groot ◽  
Albert Hofman ◽  
Gabriel Krestin ◽  
Aad van der Lugt ◽  
...  

2017 ◽  
Author(s):  
Christian K. Tamnes ◽  
David R. Roalf ◽  
Anne-Lise Goddings ◽  
Catherine Lebel

AbstractDiffusion magnetic resonance imaging (dMRI) continues to grow in popularity as a useful neuroimaging method to study brain development, and longitudinal studies that track the same individuals over time are emerging. Over the last decade, seminal work using dMRI has provided new insights into the development of brain white matter (WM) microstructure, connections and networks throughout childhood and adolescence. This review provides an introduction to dMRI, both diffusion tensor imaging (DTI) and other dMRI models, as well as common acquisition and analysis approaches. We highlight the difficulties associated with ascribing these imaging measurements and their changes over time to specific underlying cellular and molecular events. We also discuss selected methodological challenges that are of particular relevance for studies of development, including critical choices related to image acquisition, image analysis, quality control assessment, and the within-subject and longitudinal reliability of dMRI measurements. Next, we review the exciting progress in the characterization and understanding of brain development that has resulted from dMRI studies in childhood and adolescence, including brief overviews and discussions of studies focusing on sex and individual differences. Finally, we outline future directions that will be beneficial to the field.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2007 ◽  
Author(s):  
Miranda Olff ◽  
Mirjam Nijdam ◽  
Kristin Samuelson ◽  
Julia Golier ◽  
Mariel Meewisse ◽  
...  

2010 ◽  
Author(s):  
Rebecca D. Stinson ◽  
Zachary Sussman ◽  
Megan Foley Nicpon ◽  
Allison L. Allmon ◽  
Courtney Cornick ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document