scholarly journals Defining a Path Toward the Use of Fast-Scan Cyclic Voltammetry in Human Studies

2021 ◽  
Vol 15 ◽  
Author(s):  
Suelen Lucio Boschen ◽  
James Trevathan ◽  
Seth A. Hara ◽  
Anders Asp ◽  
J. Luis Lujan

Fast Scan Cyclic Voltammetry (FSCV) has been used for decades as a neurochemical tool for in vivo detection of phasic changes in electroactive neurotransmitters in animal models. Recently, multiple research groups have initiated human neurochemical studies using FSCV or demonstrated interest in bringing FSCV into clinical use. However, there remain technical challenges that limit clinical implementation of FSCV by creating barriers to appropriate scientific rigor and patient safety. In order to progress with clinical FSCV, these limitations must be first addressed through (1) appropriate pre-clinical studies to ensure accurate measurement of neurotransmitters and (2) the application of a risk management framework to assess patient safety. The intent of this work is to bring awareness of the current issues associated with FSCV to the scientific, engineering, and clinical communities and encourage them to seek solutions or alternatives that ensure data accuracy, rigor and reproducibility, and patient safety.

2019 ◽  
Vol 13 ◽  
Author(s):  
Rachel A. Saylor ◽  
Melinda Hersey ◽  
Alyssa West ◽  
Anna Marie Buchanan ◽  
Shane N. Berger ◽  
...  

2020 ◽  
Author(s):  
Elizabeth N. Holly ◽  
M. Felicia Davatolhagh ◽  
Rodrigo A. España ◽  
Marc V. Fuccillo

Low-threshold spiking interneurons (LTSIs) in the dorsomedial striatum are potent modulators of goal-directed learning. Here, we uncover a novel function for LTSIs in locally and directly gating striatal dopamine, using in vitro fast scan cyclic voltammetry as well as in vivo GRAB-DA sensor imaging and pharmacology during operant learning. We demonstrate that LTSIs, acting via GABAB signaling, attenuate dopamine release, thereby serving as local coordinators of striatal plasticity.


2019 ◽  
Vol 13 ◽  
Author(s):  
Rachel A. Saylor ◽  
Melinda Hersey ◽  
Alyssa West ◽  
Anna Marie Buchanan ◽  
Shane N. Berger ◽  
...  

Micromachines ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 494 ◽  
Author(s):  
Evan Nicolai ◽  
Nicholas Michelson ◽  
Megan Settell ◽  
Seth Hara ◽  
James Trevathan ◽  
...  

Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.


2009 ◽  
Vol 111 (4) ◽  
pp. 712-723 ◽  
Author(s):  
Jonathan M. Bledsoe ◽  
Christopher J. Kimble ◽  
Daniel P. Covey ◽  
Charles D. Blaha ◽  
Filippo Agnesi ◽  
...  

Object Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. Methods The FSCV study consisted of a triangle wave scanned between −0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 μm) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by ~ 100 μm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. Results The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus–connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. Conclusions Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.


2016 ◽  
Vol 136 (6) ◽  
pp. 1270-1283 ◽  
Author(s):  
Rashed Harun ◽  
Kristin M. Hare ◽  
Elizabeth M. Brough ◽  
Miranda J. Munoz ◽  
Christine M. Grassi ◽  
...  

2014 ◽  
Vol 14 (9) ◽  
pp. 2975-2980 ◽  
Author(s):  
Alison N. Amos ◽  
James G. Roberts ◽  
Lingjiao Qi ◽  
Leslie A. Sombers ◽  
Gregory S. McCarty

2017 ◽  
Vol 8 (2) ◽  
pp. 221-234 ◽  
Author(s):  
Nathan T. Rodeberg ◽  
Stefan G. Sandberg ◽  
Justin A. Johnson ◽  
Paul E. M. Phillips ◽  
R. Mark Wightman

Sign in / Sign up

Export Citation Format

Share Document