scholarly journals The Preoperative Diagnostic Value of MRI and Otoneural Tests in Acoustic Neuroma

2021 ◽  
Vol 11 ◽  
Author(s):  
Qingqing Dai ◽  
Meijun Zheng ◽  
Qiurong Chen ◽  
Hong Zheng ◽  
Bilan Li

ObjectivesTo determine the preoperative diagnostic accuracy of MRI and otoneural tests (ONT) for acoustic neuroma (AN) in a cohort of unselected patients with pontocerebellar angle tumors. To find a convenient way to screening out the potential asymptomatic AN patient earlier.DesignThis diagnostic accuracy study was performed in a central hospital and included a consecutive sample of unilateral incipient pontocerebellar angle tumor patients referred for MRI and ONT before surgery. Different AN features of MRI and ONT were collected and concluded into preoperative diagnostic variables or variable combinations. Those of MRI and ONT are analyzed and compared with biopsy results by multivariable receiver operating characteristic (ROC) analysis. The early-stage group, the course of which is 1 year or less, was separately computed and compared.ResultsEighty-three subjects were collected from June 2013 to June 2019; 62 were confirmed AN postoperatively by biopsy, whereas others are not AN. The area under the curve (AUC) of MRI was 0.611, whereas the AUC of ONT was 0.708. In the early-stage group, the AUC of MRI was 0.539, and the AUC of ONT was 0.744.ConclusionsONT was able to identify more subjects affected by unilateral incipient AN than MRI preoperatively. Given that ONT is a functional test for internal auditory canal nerves, it is an optimal screening test for AN patients because it provides more information than MRI for the further clinical plan. It is particularly noteworthy for identifying asymptomatic AN patients and for early stage. Therefore, it may help more patients from unnessesary surgery. Furthermore, an MRI follow-up is suggested if the patient was found alert in ONT.

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Fei Xu ◽  
Lulu Zhang ◽  
Wenting He ◽  
Di Song ◽  
Xiaomeng Ji ◽  
...  

Background. At present, the diagnostic accuracy of alpha-fetoprotein (AFP) for hepatocellular carcinoma (HCC) surveillance is insufficient. It remains controversial whether prothrombin induced by vitamin K absence II (PIVKA-II) has a better diagnostic value than AFP for HCC patients. Objective. To investigate the diagnostic role of PIVKA-II alone or in combination with AFP in Chinese HCC patients. Methods. Serum AFP and PIVKA-II levels were detected and analyzed in 308 HCC afflicted patients and 120 unafflicted controls. The receiver operator curve (ROC) and area under the curve (AUC) were conducted to evaluate the clinical value of AFP and PIVKA-II for diagnosing HCC and early HCC. Results. In the whole HCC cohort, the diagnostic values of PIVKA-II were better than that of AFP. The AUC of PIVKA-II and AFP was 0.90 (95% CI 0.87-0.94) and 0.79 (95% CI 0.74-0.84), respectively. “AFP + PIVKA-II” yielded a high sensitivity of 95.1% and a specificity of 83.3%, with the AUC 0.89 (95% CI 0.85-0.93). In the early stage HCC group, the diagnostic accuracy of PIVKA-II was also better than that of AFP. The AUC of PIVKA-II and AFP was 0.83 (95% CI 0.77-0.89) and 0.75 (95% CI 0.68-0.81), respectively. “AFP + PIVKA-II” achieved the sensitivity of 83.3% and specificity of 89.1%, with an AUC of 0.86 (95% CI 0.81-0.91). Moreover, for AFP-negative HCC patients, serum PIVKA-II showed good diagnostic performance, with an AUC of 0.804 (95% CI 0.720-0.887). Besides, elevated PIVKA-II level was a strong independent risk factor for HCC patients with portal vein tumor thrombus (PVTT) ( OR = 4.890 , P = 0.020 ). Conclusion. PIVKA-II is superior to AFP in HCC screening, and AFP in combination with PIVKA-II significantly improves the diagnostic value for Chinese HCC patients. PIVKA-II could effectively indicate HCC accompanied by PVTT and help to optimize the therapeutic strategy.


2019 ◽  
Vol 30 (04) ◽  
pp. 357-363
Author(s):  
Javier Gómez-Veiras ◽  
Ángel Salgado-Barreira ◽  
José Luis Vázquez ◽  
Margarita Montero-Sánchez ◽  
José Ramón Fernández-Lorenzo ◽  
...  

Introduction The aim of this study was to assess the diagnostic value of the biomarker fibrinogen (FB), along with the markers white blood cell (WBC) count, absolute neutrophil count (ANC), and C-reactive protein (CRP), to discriminate appendicitis from nonspecific abdominal pain (NSAP) in preschool children. Materials and Methods We prospectively evaluated all children aged <5 years admitted for suspected appendicitis at an academic pediatric emergency department during 5 years. Diagnostic accuracy of FB (prothrombin time–derived method), WBC, ANC, and CRP were assessed by the area under the curve (AUC) of the receiver-operating characteristic curve. Results A total of 82 patients were enrolled in the study (27 NSAP, 17 uncomplicated, and 38 complicated appendicitides). WBC and ANC had moderate diagnostic accuracy for appendicitis versus NSAP (WBC: AUC 0.66, ANC: AUC 0.67). CRP and FB had good diagnostic accuracy for appendicitis versus NSAP (CRP: AUC 0.78, FB: AUC 0.77). WBC and ANC are not useful to discriminate complicated versus uncomplicated appendicitis (WBC: AUC 0.43, ANC: AUC 0.45). CPR and FB had good diagnostic accuracy for complicated versus uncomplicated appendicitis (CRP: AUC 0.80, FB: AUC 0.73). Conclusion CRP and FB are more useful than WBC and ANC to discriminate appendicitis from NSAP in preschool children. CRP and FB are especially useful to discriminate complicated from uncomplicated appendicitis and NSAP. In a child with suspected appendicitis, a plasma FB level (prothrombin time–derived method) >540 mg/dL is associated with an increased likelihood of complicated appendicitis.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Yanping Zhou ◽  
Minlu Song ◽  
Minwen Zhou ◽  
Yiming Liu ◽  
Fenghua Wang ◽  
...  

Purpose. To investigate the choroidal thickness (CT) and retinal thickness (RT) in highly myopic tessellated eyes. Methods. In this study, 115 highly myopic eyes were recruited and divided as tessellated fundus (n=93) and normal fundus (n=22). RT and CT were quantified using optical coherence tomography with enhanced depth imaging (EDI-OCT). Correlation between subfoveal CT (SFCT) and tessellation was analyzed using logistic regression models. Results. Tessellated fundus eyes had thinner CT than did normal fundus eyes, while RT was not statistically different across groups. The tessellated eyes had a thinner choroid than did the control eyes at all measured macular locations (all P<0.05). After adjustment for AL, age, and gender, the SFCT was significantly associated with tessellation. The odds ratio (OR) and 95% confidence interval (CI) was 0.975 (0.960–0.990, P=0.001, binary logistics regression) and 0.991 (0.984–0.999, P=0.022, Cox regression). The area under the curve (AUC) of SFCT was the greatest for detecting tessellation (AUC = 0.824, P<0.001). For sensitivity and specificity analyses, SFCT had the highest diagnostic value (sensitivity = 81.8%, specificity = 74.2%). Conclusions. Highly myopic eyes with tessellation have thinner CT than do normal highly myopic eyes. CT may serve as an early pathologic predictor of high myopia.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


Author(s):  
Luís Cabral ◽  
Mariana Fernandes ◽  
Sérgio Marques ◽  
Rita Meireles ◽  
Marisa Caetano ◽  
...  

Abstract Despite continuous advances in burn care, sepsis is still the main cause of death in burn patients. Procalcitonin (PCT) has been reported as an accurate sepsis biomarker and also as a fair predictor of death. The aim of this study was to assess PCT kinetics in the first week postburn regarding sepsis diagnosis and death prognosis. Sample included 142 patients with ≥15% TBSA, admitted from January 2011 to December 2014 at Coimbra Burns Unit, Portugal. Sepsis diagnosis was done according to American Burn Association criteria. PCT range and median values in the first 7 days after burns were statistically analyzed for its potential for sepsis diagnosis and death prognosis. A subanalysis was done regarding TBSA, sex, age, and inhalation injury. First week PCT range and median were significant for sepsis diagnosis and death prognosis, but the median area under the curve was greater in the last case. TBSA influenced PCT accuracy, which was greater for TBSA less than 40% either for diagnosis or prognosis. Age was inversely related to the accuracy, being better in younger than 40 years in both cases. PCT diagnostic accuracy was not affected by sex, opposing to the prognostic one which is better in women. Inhalation injury had no effect on diagnostic accuracy, but it happens with prognostic accuracy. PCT levels’ variation is related to sepsis evolution and outcome. Its median performs better than its range. Always coupled with clinical examination, monitoring PCT levels kinetics may help early sepsis detection, potentially reducing morbidity and mortality, being also useful for death prognosis.


Biomolecules ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 1059
Author(s):  
Sarah Atef Fahim ◽  
Mahmoud Salah Abdullah ◽  
Nancy A. Espinoza-Sánchez ◽  
Hebatallah Hassan ◽  
Ayman M. Ibrahim ◽  
...  

Inflammatory breast cancer (IBC) is a rare yet aggressive breast cancer variant, associated with a poor prognosis. The major challenge for IBC is misdiagnosis due to the lack of molecular biomarkers. We profiled dysregulated expression of microRNAs (miRNAs) in primary samples of IBC and non-IBC tumors using human breast cancer miRNA PCR array. We discovered that 28 miRNAs were dysregulated (10 were upregulated, while 18 were underexpressed) in IBC vs. non-IBC tumors. We identified 128 hub genes, which are putative targets of the differentially expressed miRNAs and modulate important cancer biological processes. Furthermore, our qPCR analysis independently verified a significantly upregulated expression of miR-181b-5p, whereas a significant downregulation of miR-200b-3p, miR-200c-3p, and miR-203a-3p was detected in IBC tumors. Receiver operating characteristic (ROC) curves implied that the four miRNAs individually had a diagnostic accuracy in discriminating patients with IBC from non-IBC and that miR-203a-3p had the highest diagnostic value with an AUC of 0.821. Interestingly, a combination of miR-181b-5p, miR-200b-3p, and miR-200c-3p robustly improved the diagnostic accuracy, with an area under the curve (AUC) of 0.897. Intriguingly, qPCR revealed that the expression of zinc finger E box-binding homeobox 2 (ZEB2) mRNA, the putative target of miR-200b-3p, miR-200c-3p, and miR-203a-3p, was upregulated in IBC tumors. Overall, this study identified a set of miRNAs serving as potential biomarkers with diagnostic relevance for IBC.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 898
Author(s):  
Jun-Gyu Lee ◽  
Hyung-Sun Peo ◽  
Jang-Hyuk Cho ◽  
Chul-Hyun Cho ◽  
Don-Kyu Kim ◽  
...  

The diagnostic value of ultrasonography (US) for frozen shoulder (FS) is not well established. This study aimed to assess the diagnostic value of US measurement of inferior joint capsule (IJC) thickness and evaluate changes in the thickness of the IJC by US depending on arm position. A total of 71 patients with clinically diagnosed unilateral FS who underwent bilateral US measurement of the IJC were enrolled in this study. The US measurement of the IJC was performed with a linear transducer positioned around the anterior axillary line with the shoulder 40° abducted and with neutral rotation of the glenohumeral joint (neutral position). We also measured the IJC thickness in the externally rotated and internally rotated positions with the shoulder 40° abducted. In the neutral position, as well as in the internally rotated and externally rotated positions, the thickness of the IJC on US was significantly higher in the affected shoulder than that in the unaffected shoulder (all p < 0.001). On both the affected and unaffected sides, the US thickness of the IJC in the neutral position was significantly higher than that in the externally rotated position (p < 0.001), but lower than that in the internally rotated position (p < 0.001). Regarding IJC thickness in the neutral position, a 3.2-mm cutoff value yielded the highest diagnostic accuracy for FS, with a sensitivity and specificity of 73.2% and 77.5%, respectively. The area under the curve for IJC thickness was 0.824 (95% confidence interval, 0.76–0.89). US measurement of the IJC in the neutral position yielded good diagnostic accuracy for FS. Because IJC thickness is affected by arm rotation, it is important to measure the IJC thickness in a standardized posture to ensure diagnostic value.


2020 ◽  
Author(s):  
Juanjuan Chen ◽  
Dongling Tang ◽  
Chu Xu ◽  
Zhili Niu ◽  
Huan Li ◽  
...  

Abstract Objective To evaluate the potential diagnostic value of growth differentiation factor 15 (GDF15) alone and its combination with protein induced by vitamin K absence-II (PIVKA-II) and alpha-fetoprotein (AFP) for hepatitis B virus (HBV)-associated hepatocellular carcinoma (HCC). Methods Serum levels of GDF15, PIVKA-II, and AFP were measured in 110 patients with HBV-associated HCC, 70 patients with HBV-related liver cirrhosis (LC), 70 patients with chronic hepatitis B (CHB), and 110 healthy patients. Results Serum GDF15 was positively related to the levels of PIVKA-II and AFP in patients with HCC (r = 0.352 and r = 0.378; all P &lt;.0001). When the receiver operating characteristic (ROC) curve was plotted for patients with HCC vs all control patients, serum GDF15 had diagnostic parameters of an area under the curve (AUC) of 0.693, a sensitivity of 67.30%, and a specificity of 66.70%, which were lower than parameters for PIVKA-II and AFP (all P &lt;.0001). When the ROC curve was plotted for patients with HCC vs patients with LC, the combination of GDF15 and PIVKA-II had the highest diagnostic accuracy of AUC and specificity as compared with other combinations (all P &lt;.0001). Conclusion We found that GDF15 is a potent serum marker for the detection of HBV-associated HCC and that PIVKA-II combined with GDF15 can improve diagnostic accuracy for HBV-associated HCC.


2020 ◽  
Vol 40 (3) ◽  
Author(s):  
Qingqing Lu ◽  
Jie Li ◽  
Hui Cao ◽  
Chenlu Lv ◽  
Xiaolin Wang ◽  
...  

Abstract Objective: Midkine (MDK) has been proposed as one of the most promising markers for hepatocellular carcinoma (HCC). This meta-analysis was conducted to compare the diagnostic accuracy of MDK and α-fetoprotein (AFP) for HCC. Methods: We systematically searched PubMed/MEDLINE, Ovid/EMBASE, and the Cochrane Library for all relevant studies up to 18 May 2019. The Revised Quality Assessment for Studies of Diagnostic Accuracy tool (QUADAS-2) was used to assess the methodological quality of the included studies. The sensitivity, specificity, and the area under the curve (AUC) of MDK and AFP for detecting HCC were pooled using random-effects model. Results: Seventeen studies from five articles with a total of 1122 HCC patients and 2483 controls were included. The summary estimates using MDK and AFP for detecting HCC were as follows: sensitivity, 85 vs 52%, specificity, 82 vs 94%, and AUC, 0.90 vs 0.83. The summary estimates using MDK and AFP for detecting hepatitis virus-related HCC as follows: sensitivity, 93 vs 74%, specificity, 85 vs 97%, and AUC, 0.95 vs 0.97. The summary estimates using MDK and AFP for detecting early-stage HCC were as follows: sensitivity, 83.5 vs 44.4%, specificity, 81.7 vs 84.8%, and AUC, 0.87 vs 0.52. The summary estimates using MDK for detecting AFP-negative HCC as follows: sensitivity, 88.5%, specificity, 83.9%, and AUC, 0.91. Conclusion: MDK is more accurate than AFP in diagnosing HCC, especially for early-stage HCC and AFP-negative HCC. Both MDK and AFP had excellent diagnostic performance for hepatitis virus-related HCC.


2020 ◽  
Author(s):  
Kirby Tong-Minh ◽  
Iris Welten ◽  
Henrik Endeman ◽  
Tjebbe Hagenaars ◽  
Christian Ramakers ◽  
...  

Abstract Introduction Sepsis can be detected in an early stage in the emergency department (ED) by biomarkers and clinical scoring systems. A combination of multiple biomarkers or biomarker with clinical scoring system might result in a higher predictive value on mortality. The goal of this systematic review is to evaluate the available literature on combinations of biomarkers and clinical scoring systems on 1-month mortality in patients with sepsis in the ED.Methods We performed a systematic search using MEDLINE, PubMed, EMBASE and Google Scholar. Articles were included if they evaluated at least one biomarker combined with another biomarker or clinical scoring system and reported the diagnostic accuracy on 28 or 30 day mortality by area under the curve (AUC) in patients with sepsis. Results We found 18 articles in this systematic review. In these 18 articles, a total of 35 combinations of biomarkers and clinical scoring systems were studied of which 33 unique combinations. In total, seven different clinical scoring systems and 21 different biomarkers were investigated. The combination of procalcitonin (PCT), lactate, interleukin-6 (IL-6) and Simplified Acute Physiology Score-2 (SAPS-2) resulted in the highest AUC on 1-month mortality. Conclusion In this systematic review, the combination of PCT, IL-6, lactate and the SAPS-2 score had the highest AUC on 1-month mortality in patients with sepsis in the ED. The studies we found in this review were too heterogeneous to conclude that a certain combination it should be used in the ED to predict 1-month mortality in patients with sepsis.


Sign in / Sign up

Export Citation Format

Share Document