scholarly journals Algorithm for Mapping Kidney Tissue Water Content during Normothermic Machine Perfusion Using Hyperspectral Imaging

Algorithms ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 289
Author(s):  
Wenke Markgraf ◽  
Jannis Lilienthal ◽  
Philipp Feistel ◽  
Christine Thiele ◽  
Hagen Malberg

The preservation of kidneys using normothermic machine perfusion (NMP) prior to transplantation has the potential for predictive evaluation of organ quality. Investigations concerning the quantitative assessment of physiological tissue parameters and their dependence on organ function lack in this context. In this study, hyperspectral imaging (HSI) in the wavelength range of 500–995 nm was conducted for the determination of tissue water content (TWC) in kidneys. The quantitative relationship between spectral data and the reference TWC values was established by partial least squares regression (PLSR). Different preprocessing methods were applied to investigate their influence on predicting the TWC of kidneys. In the full wavelength range, the best models for absorbance and reflectance spectra provided Rp2 values of 0.968 and 0.963, as well as root-mean-square error of prediction (RMSEP) values of 2.016 and 2.155, respectively. Considering an optimal wavelength range (800–980 nm), the best model based on reflectance spectra (Rp2 value of 0.941, RMSEP value of 3.202). Finally, the visualization of TWC distribution in all pixels of kidneys’ HSI image was implemented. The results show the feasibility of HSI for a non-invasively and accurate TWC prediction in kidneys, which could be used in the future to assess the quality of kidneys during the preservation period.

2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Maximilian Dietrich ◽  
Sebastian Marx ◽  
Maik von der Forst ◽  
Thomas Bruckner ◽  
Felix C. F. Schmitt ◽  
...  

Abstract Background Hyperspectral imaging (HSI) could provide extended haemodynamic monitoring of perioperative tissue oxygenation and tissue water content to visualize effects of haemodynamic therapy and surgical trauma. The objective of this study was to assess the capacity of HSI to monitor skin microcirculation and possible relations to perioperative organ dysfunction in patients undergoing pancreatic surgery. Methods The hyperspectral imaging TIVITA® Tissue System was used to evaluate superficial tissue oxygenation (StO2), deeper layer tissue oxygenation (near-infrared perfusion index (NPI)), haemoglobin distribution (tissue haemoglobin index (THI)) and tissue water content (tissue water index (TWI)) in 25 patients undergoing pancreatic surgery. HSI parameters were measured before induction of anaesthesia (t1), after induction of anaesthesia (t2), postoperatively before anaesthesia emergence (t3), 6 h after emergence of anaesthesia (t4) and three times daily (08:00, 14:00, 20:00 ± 1 h) at the palm and the fingertips until the second postoperative day (t5–t10). Primary outcome was the correlation of HSI with perioperative organ dysfunction assessed with the perioperative change of SOFA score. Results Two hundred and fifty HSI measurements were performed in 25 patients. Anaesthetic induction led to a significant increase of tissue oxygenation parameters StO2 and NPI (t1–t2). StO2 and NPI decreased significantly from t2 until the end of surgery (t3). THI of the palm showed a strong correlation with haemoglobin levels preoperatively (t2:r = 0.83, p < 0.001) and 6 h postoperatively (t4: r = 0.71, p = 0.001) but not before anaesthesia emergence (t3: r = 0.35, p = 0.10). TWI of the palm and the fingertip rose significantly between pre- and postoperative measurements (t2–t3). Higher blood loss, syndecan level and duration of surgery were associated with a higher increase of TWI. The perioperative change of HSI parameters (∆t1–t3) did not correlate with the perioperative change of the SOFA score. Conclusion This is the first study using HSI skin measurements to visualize tissue oxygenation and tissue water content in patients undergoing pancreatic surgery. HSI was able to measure short-term changes of tissue oxygenation during anaesthetic induction and pre- to postoperatively. TWI indicated a perioperative increase of tissue water content. Perioperative use of HSI could be a useful extension of haemodynamic monitoring to assess the microcirculatory response during haemodynamic therapy and major surgery. Trial registration German Clinical Trial Register, DRKS00017313 on 5 June 2019


2018 ◽  
Vol 63 (5) ◽  
pp. 557-566 ◽  
Author(s):  
Wenke Markgraf ◽  
Philipp Feistel ◽  
Christine Thiele ◽  
Hagen Malberg

Abstract The lack of donor grafts is a severe problem in transplantation medicine. Hence, the improved preservation of existing and the usage of organs that were deemed untransplantable is as urgent as ever. The development of novel preservation techniques has come into focus. A promising alternative to traditional cold storage is normothermic machine perfusion (NMP), which provides the benefit of improving the organs’ viability and of assessing the organs’ status under physiological conditions. For this purpose, methods for evaluating organ parameters have yet to be developed. In a previous study, we determined the tissue oxygen saturation (StO2) of kidneys during NMP with hyperspectral imaging (HSI) based on a discrete wavelength (DW) algorithm. The aim of the current study was to identify a more accurate algorithm for StO2 calculation. A literature search revealed three candidates to test: a DW algorithm and two full spectral algorithms – area under a curve and partial least square regression (PLSR). After obtaining suitable calibration data to train each algorithm, they were evaluated during NMP. The wavelength range from 590 to 800 nm was found to be appropriate for analyzing StO2 of kidneys during NMP. The PLSR method shows good results in analyzing the tissues’ oxygen status in perfusion experiments.


2013 ◽  
Vol 119 (4) ◽  
pp. 861-870 ◽  
Author(s):  
Hege Kristin Brekke ◽  
Stig Morten Hammersborg ◽  
Steinar Lundemoen ◽  
Arve Mongstad ◽  
Venny Lise Kvalheim ◽  
...  

Abstract Background: A highly positive intraoperative fluid balance should be prevented as it negatively impacts patient outcome. Analysis of volume-kinetics has identified an increase in interstitial fluid volume after crystalloid fluid loading during isoflurane anesthesia. Isoflurane has also been associated with postoperative hypoxemia and may be associated with an increase in alveolar epithelial permeability, edema formation, and hindered oxygen exchange. In this article, the authors compare fluid extravasation rates before and during cardiopulmonary bypass (CPB) with isoflurane- versus propofol-based anesthesia. Methods: Fourteen pigs underwent 2 h of tepid CPB with propofol (P-group; n = 7) or isoflurane anesthesia (I-group; n = 7). Fluid requirements, plasma volume, colloid osmotic pressures in plasma and interstitial fluid, hematocrit levels, and total tissue water content were recorded, and fluid extravasation rates calculated. Results: Fluid extravasation rates increased in the I-group from the pre-CPB level of 0.27 (0.13) to 0.92 (0.36) ml·kg−1·min−1, but remained essentially unchanged in the P-group with significant between-group differences during CPB (pb = 0.002). The results are supported by corresponding changes in interstitial colloid osmotic pressure and total tissue water content. Conclusions: During CPB, isoflurane, in contrast to propofol, significantly contributes to a general increase in fluid shifts from the intravascular to the interstitial space with edema formation and a possible negative impact on postoperative organ function.


1987 ◽  
Vol 17 (10) ◽  
pp. 1228-1233 ◽  
Author(s):  
Joanna T. Tippett ◽  
Joanne L. Barclay

A new instrument, the plant impedance ratio meter (PIRM), has been used to determine the extent of lesions caused by Phytophthoracinnamomi Rands in Eucalyptusmarginata Sm. The performance of the PIRM, which measures electrical admittance (the inverse of impedance) of plant tissues at two frequencies (from which an impedance ratio is calculated), was evaluated and compared with that of the Shigometer. The electrical admittance measured at 1 and 10 kHz (PIRM) and the electrical resistance (Shigometer) of healthy tissue varied with both the depth of tissue probed and the water status of stems. However, the impedance ratios (calculated from the admittance values) remained relatively constant for healthy tissue and changes were independent of depth of probing. Hence, changes in ratios indicated a change in tissue condition or necrosis rather than changes in either tissue water content or depth of probing. The impedance ratios recorded for healthy bark tissues were consistently higher than those for the P. cinnamomi lesions in E. marginata. Trends in electrical resistance measured across the boundaries of the lesions with the Shigometer were variable depending on lesion age. The PIRM was used successfully to detect P. cinnamomi lesions in E. marinate and lesion fronts were predicted to an accuracy of ± 7.2 mm (n = 150), lesions being up to 1.0 m long at the time stems were harvested.


2018 ◽  
Vol 17 (2) ◽  
pp. e767 ◽  
Author(s):  
W. Markgraf ◽  
M.W.W. Janssen ◽  
J. Lilienthal ◽  
P. Feistel ◽  
C. Thiele ◽  
...  

1989 ◽  
Vol 69 (2) ◽  
pp. 355-366 ◽  
Author(s):  
A. L. BRULE-BABEL ◽  
D. B. FOWLER

Field survival is the most commonly employed method of evaluating the winter hardiness of cereals. However, the inherent difficulties with field trials have stimulated a continued interest in the use of controlled environments and prediction tests for the evaluation of cold hardiness. In the present studies, cold hardiness expression of wheat (Triticum aestivum L.) cultivars acclimated in controlled environments was found to be similar to that reported for field conditions in Saskatchewan, Canada. LT50 and tissue water content measurements on wheat and rye (Secale cereale L.) cultivars acclimated in controlled environments were highly correlated with cultivar field survival ability. Investigation of the relationship between field survival and tissue water content during cold acclimation in controlled environments indicated that, to be effective as a screening method for cold hardiness, measurements of tissue water content should be made on fully acclimated plants for which the acclimation conditions have been rigorously controlled. Level of acclimation was not as critical for cold hardiness screening when LT50 measurements were utilized; however, maximum resolution also required fully acclimated plants. Although a strong relationship (r = −0.80 to −0.89) was found to exist with field survival potential, an inability to detect small, but important, differences without excessive replication would generally restrict the use of LT50 and tissue water content to situations where large homogeneous plant populations were available and only coarse screens for cold hardiness were required.Key words: Cold acclimation, winter wheat, winter rye, cold hardiness, water content, replication


1981 ◽  
Vol 59 (12) ◽  
pp. 2707-2712 ◽  
Author(s):  
Mark W. Schonbeck ◽  
J. Derek Bewley

Variations in the apparent desiccation tolerance of the moss Tortula ruralis were traced to several causes. When the moss was kept continuously hydrated for several days, desiccation tolerance tended to decrease ("dehardening"). Conversely, daily episodes of drying and rehydration induced hardening so that the moss could tolerate rapid drying to a tissue water content of 0.008 g∙g dry weight−1.Different clumps of moss showed very different degrees of desiccation tolerance. The least tolerant samples suffered severe damage after rapid drying, whereas the most tolerant suffered little damage, and did not deharden during 3 days continuous hydration.


Sign in / Sign up

Export Citation Format

Share Document