scholarly journals Atmospheric Mercury Pollution in the Xi’an Area, China, Studied by Differential Absorption Lidar

Atmosphere ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 27
Author(s):  
Zheng Duan ◽  
Guangyu Zhao ◽  
Shiming Zhu ◽  
Ming Lian ◽  
Yiyun Li ◽  
...  

Measurements of the atmospheric concentration of polluting atomic mercury were performed using the differential absorption lidar (DIAL) technique in the Lintong district, about 35 km northeast of Xi’an, the capital of the Shaanxi province, China. Concentrations ranging from 2 to 13 ng/m3 were observed. As uniquely enabled by the lidar technique, representative average concentrations, integrated over a considerable volume, were recorded and put in relation to weather conditions, and vertical concentration profiles were measured. Considerable local non-uniformities were also observed, which may indicate the presence of localized hot-spots in the area, possibly related to ancient tombs.

2020 ◽  
Vol 237 ◽  
pp. 03003
Author(s):  
Guangyu Zhao ◽  
Zheng Duan ◽  
Ming Lian ◽  
Sune Svanberg

Mercury is a very serious environmental pollutant which is intensely studied by many researchers. China is a main producer and consumer of mercury. We have pursued extensive monitoring of atomic mercury using the differential absorption lidar (DIAL) technique, based on a newly constructed mobile monitoring system. Mercury levels in major cities (Guangzhou, Zhengzhou, Xi´a n) were measured, as well as in mercury mining areas in Wanshan, Guizhou province. Further, mercury emissions from the Emperor Qin Mausoleum in Xi´an were investigated together with archaeologists.


1989 ◽  
Vol 28 (5) ◽  
pp. 921 ◽  
Author(s):  
Hans Edner ◽  
Gregory W. Faris ◽  
Anders Sunesson ◽  
Sune Svanberg

2018 ◽  
Vol 176 ◽  
pp. 05045 ◽  
Author(s):  
Erwan Cadiou ◽  
Jean-Baptiste Dherbecourt ◽  
Guillaume Gorju ◽  
Jean-Michel Melkonian ◽  
Antoine Godard ◽  
...  

We report on ground-based atmospheric concentration measurements of carbon dioxide, using a pulsed direct detection differential absorption lidar operating at 2051 nm. The transmitter is based on a tunable parametric source emitting 10-mJ energy, 10-ns duration Fourier-limited pulses. Range resolved concentration measurements have been carried out on the aerosol back-scattered signal. Cloud signals have been used to get long range integrated-path measurements.


1992 ◽  
Vol 97 (D4) ◽  
pp. 3779 ◽  
Author(s):  
H. Edner ◽  
P. Ragnarson ◽  
S. Svanberg ◽  
E. Wallinder ◽  
A. De Liso ◽  
...  

2004 ◽  
Vol 43 (35) ◽  
pp. 6487 ◽  
Author(s):  
Takuya Nayuki ◽  
Kohji Marumoto ◽  
Takashi Fujii ◽  
Tetsuo Fukuchi ◽  
Koshichi Nemoto ◽  
...  

1991 ◽  
Vol 54 (1) ◽  
pp. 45-52
Author(s):  
S. E. Sholupov ◽  
A. A. Ganeev ◽  
O. I. Matveev ◽  
G. B. Sveshnikov ◽  