scholarly journals A Useful Combination of Quantitative Ultrashort Echo Time MR Imaging and a Probing Device for Biomechanical Evaluation of Articular Cartilage

Biosensors ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 52
Author(s):  
Takehito Hananouchi ◽  
Yanjun Chen ◽  
Saeed Jerban ◽  
Masaru Teramoto ◽  
Yajun Ma ◽  
...  

In this study, we combined quantitative ultrashort echo time (UTE) magnetic resonance (MR) imaging and an investigation by a probing device with tri-axial force sensor to seek correlations with mechanical properties of human patellar cartilage for in situ evaluation of biomechanical properties. Cartilage blocks (15 × 20 × 5 mm3) were dissected from the patella of six donors; 5 mm square regions of interest from the cartilage blocks were imaged using UTE-MR imaging sequences (T2* and magnetization transfer ratio (MTR)), and mechanical properties were measured using a micro indentation device. Then, the vertical reaction force on the cartilage surface was measured while push-probing forward 3 mm with the probing device at a 30° tilt to the horizontal plane. The results showed a positive correlation between stiffness/elastic modulus and each predictor variable (UTE-T2* (r = 0.240 and 0.255, respectively, UTE-MTR (r = 0.378 and 0.379, respectively), and probing device force (r = 0.426 and 0.423, respectively). Furthermore, multiple linear regression analysis showed the combination of the three predictors had stronger correlation (adjusted r2 = 0.314 (stiffness), 0.323 (elastic), respectively). Our results demonstrate the potential for these non- and less- invasive methods for in situ evaluation of the mechanical properties of cartilage tissue.

Bone ◽  
2019 ◽  
Vol 127 ◽  
pp. 120-128 ◽  
Author(s):  
Saeed Jerban ◽  
Yajun Ma ◽  
Liang Li ◽  
Hyungseok Jang ◽  
Lidi Wan ◽  
...  

2019 ◽  
Vol 21 (6) ◽  
pp. 1003-1019 ◽  
Author(s):  
Simone Mastrogiacomo ◽  
Weiqiang Dou ◽  
John A. Jansen ◽  
X. Frank Walboomers

Abstract Magnetic resonance imaging (MRI) is a non-invasive diagnostic imaging tool based on the detection of protons into the tissues. This imaging technique is remarkable because of high spatial resolution, strong soft tissue contrast and specificity, and good depth penetration. However, MR imaging of hard tissues, such as bone and teeth, remains challenging due to low proton content in such tissues as well as to very short transverse relaxation times (T2). To overcome these issues, new MRI techniques, such as sweep imaging with Fourier transformation (SWIFT), ultrashort echo time (UTE) imaging, and zero echo time (ZTE) imaging, have been developed for hard tissues imaging with promising results reported. Within this article, MRI techniques developed for the detection of hard tissues, such as bone and dental tissues, have been reviewed. The main goal was thus to give a comprehensive overview on the corresponding (pre-) clinical applications and on the potential future directions with such techniques applied. In addition, a section dedicated to MR imaging of novel biomaterials developed for hard tissue applications was given as well.


2018 ◽  
Vol 39 (10) ◽  
pp. 1903-1906 ◽  
Author(s):  
J.P. Guenette ◽  
R.T. Seethamraju ◽  
J. Jayender ◽  
C.E. Corrales ◽  
T.C. Lee

Radiology ◽  
2016 ◽  
Vol 278 (2) ◽  
pp. 413-421 ◽  
Author(s):  
Peter Bannas ◽  
Laura C. Bell ◽  
Kevin M. Johnson ◽  
Mark L. Schiebler ◽  
Christopher J. François ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document