scholarly journals Correlations of cortical bone microstructural and mechanical properties with water proton fractions obtained from ultrashort echo time (UTE) MRI tricomponent T2* model

2019 ◽  
Vol 33 (3) ◽  
Author(s):  
Saeed Jerban ◽  
Xing Lu ◽  
Erik W. Dorthe ◽  
Salem Alenezi ◽  
Yajun Ma ◽  
...  

Bone Reports ◽  
2019 ◽  
Vol 11 ◽  
pp. 100220 ◽  
Author(s):  
Saeed Jerban ◽  
Yajun Ma ◽  
Erik W. Dorthe ◽  
Lena Kakos ◽  
Nicole Le ◽  
...  


2020 ◽  
Vol 67 ◽  
pp. 85-89 ◽  
Author(s):  
Saeed Jerban ◽  
Yajun Ma ◽  
Hyungseok Jang ◽  
Behnam Namiranian ◽  
Nicole Le ◽  
...  


Biosensors ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 52
Author(s):  
Takehito Hananouchi ◽  
Yanjun Chen ◽  
Saeed Jerban ◽  
Masaru Teramoto ◽  
Yajun Ma ◽  
...  

In this study, we combined quantitative ultrashort echo time (UTE) magnetic resonance (MR) imaging and an investigation by a probing device with tri-axial force sensor to seek correlations with mechanical properties of human patellar cartilage for in situ evaluation of biomechanical properties. Cartilage blocks (15 × 20 × 5 mm3) were dissected from the patella of six donors; 5 mm square regions of interest from the cartilage blocks were imaged using UTE-MR imaging sequences (T2* and magnetization transfer ratio (MTR)), and mechanical properties were measured using a micro indentation device. Then, the vertical reaction force on the cartilage surface was measured while push-probing forward 3 mm with the probing device at a 30° tilt to the horizontal plane. The results showed a positive correlation between stiffness/elastic modulus and each predictor variable (UTE-T2* (r = 0.240 and 0.255, respectively, UTE-MTR (r = 0.378 and 0.379, respectively), and probing device force (r = 0.426 and 0.423, respectively). Furthermore, multiple linear regression analysis showed the combination of the three predictors had stronger correlation (adjusted r2 = 0.314 (stiffness), 0.323 (elastic), respectively). Our results demonstrate the potential for these non- and less- invasive methods for in situ evaluation of the mechanical properties of cartilage tissue.



2011 ◽  
Vol 34 (3) ◽  
pp. 691-695 ◽  
Author(s):  
Roland Krug ◽  
Peder Eric Zufall Larson ◽  
Chunsheng Wang ◽  
Andrew J. Burghardt ◽  
Douglas A.C. Kelley ◽  
...  




Bone ◽  
2019 ◽  
Vol 127 ◽  
pp. 120-128 ◽  
Author(s):  
Saeed Jerban ◽  
Yajun Ma ◽  
Liang Li ◽  
Hyungseok Jang ◽  
Lidi Wan ◽  
...  


2019 ◽  
Vol 61 (6) ◽  
pp. 760-767
Author(s):  
Sha Li ◽  
Xinrui Huang ◽  
Guozhen Li ◽  
Yibao Zhang ◽  
Zhaotong Li ◽  
...  

Background Short T2 tissues can be directly visualized by dual-echo ultrashort echo time imaging with weighted subtraction. As a type of post-processing method, exponential subtraction of ultrashort echo time images with an optimal exponential factor is expected to provide improved positive short T2 contrast. Purpose To test the feasibility and effectiveness of exponential subtraction in three-dimensional ultrashort echo time imaging and to determine the optimal exponential factor. Material and Methods A dual-echo three-dimensional ultrashort echo time sequence was implemented on a 3-T MRI system. Exponential subtraction was performed on dual three-dimensional ultrashort echo time images of the tibia of seven healthy volunteers with exponential factors in the range of 1.00–3.00 in increments of 0.01. The regions of interest, including cortical bone, marrow, and muscle, were depicted on subtracted images of different exponential factors. Contrast-to-noise ratio values were calculated from these regions of interest and then used to assess the optimal exponential factor. To determine intra-observer agreement regarding region of interest selection, paired intra-observer measurements of regions of interest in all direct subtraction images were conducted with a one-week interval and the paired measurements were assessed using Bland–Altman analysis and paired-samples t-test. Results Cortical bone can be better visualized by using exponential subtraction in three-dimensional ultrashort echo time imaging; the suggested optimal exponential factor is 1.99–2.03 in the tibia. Paired measurements showed excellent intra-observer agreement. Conclusion It is feasible to visualize cortical bone of the tibia using exponential subtraction in three-dimensional ultrashort echo time imaging. Compared with weighted subtraction images, exponential subtraction images with an optimal exponential factor provide enhanced visualization of short T2 tissues.



2015 ◽  
Vol 28 (7) ◽  
pp. 873-880 ◽  
Author(s):  
Eric Y. Chang ◽  
Won C. Bae ◽  
Hongda Shao ◽  
Reni Biswas ◽  
Shihong Li ◽  
...  