scholarly journals Investigation on the Mechanism of Heat Load Reduction for the Thermal Anti-Icing System

Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5911
Author(s):  
Rongjia Li ◽  
Guangya Zhu ◽  
Dalin Zhang

The aircraft ice protection system that can guarantee flight safety consumes a part of the energy of the aircraft, which is necessary to be optimized. A study for the mechanism of the heat load reduction in the thermal anti-icing system under the evaporative mode was presented. Based on the relationship between the anti-icing heat load and the heating power distribution, an optimization method involved in the genetic algorithm was adopted to optimize the anti-icing heat load and obtain the optimal heating power distribution. An experiment carried out in an icing wind tunnel was conducted to validate the optimized results. The mechanism of the anti-icing heat load reduction was revealed by analyzing the influences of the key factors, such as the heating range, the surface temperature and the convective heat transfer coefficient. The results show that the reduction in the anti-icing heat load is actually the decrease in the convective heat load. In the evaporative mode, decreasing the heating range outside the water droplet impinging limit can reduce the convective heat load. Evaporating the runback water in the high-temperature region can lead to the less convective heat load. For the airfoil, the heating power distribution that has an opposite trend with the convective heat transfer coefficient can reduce the convective heat load. Thus, the optimal heating power distribution has such a trend that is low at the leading edge, high at the water droplet impinging limit and zero at the end of the protected area.

Author(s):  
Feng Sun ◽  
G. Aguilar ◽  
K. M. Kelly ◽  
G.-X. Wang

Basel cell carcinoma (BCC) is the most common human skin malignancy. Its incidence has increased significantly in Australia, Europe and North America over the past decade. A number of modalities are currently used for treatment of BCC, including cryosurgery which offers a potential for high cure rate, low cost, minimal bleeding and good cosmetic effect. However, cryosurgery is not used frequently for BCC because no current method exists to design adequate treatment parameters. We present a numerical analysis on the thermal history of the target tissue during cryosurgery of a nodular BCC using liquid nitrogen (LN2) spray. The model uses Pennes equation to describe the heat transfer within the target tissue. A convective thermal boundary is used to describe the heat interaction between the tissue and LN2, and the apparent heat capacity method is applied to address the tissue phase change process. A parametric study is conducted on the convective heat transfer coefficient (hs: 104~106 W/m2·K), cooling site area (rs/R0: 0.5~1.0) and spray time (t: 0~30 sec.), with the objective to understand the thermal history during tissue freezing, including lethal temperature (-50 °C) and cooling rate (CR). Results demonstrate that propagation of the lethal isotherm is sensitive to the convective heat transfer coefficient, hs, with a range of 104~5×104 W/m2·K. Increasing the cooling site area can significantly enhance cooling efficiency, producing dramatic increase in the amount of tissue encompassed by the lethal isotherm. The cooling rate (CR) shows a highly dynamic distribution during the cooling process: the highest CR drops quickly from 140 °C/sec. (t=0.5 sec.) to 20 °C/sec. (t=5 sec.). The highest CR is initially located close to the cooling site but moves toward the inside of the tissue as treatment proceeds. The model presented herein provides a simulation tool for treatment planning of cryosurgery using LN2 spray, in which the protocol parameters, e.g. cooling site area and spray time, can be determined for an optimal outcome. The quantitative predictions on the propagation of lethal isotherm and the distribution of CR should help to optimize cryosurgery efficacy.


Sign in / Sign up

Export Citation Format

Share Document