scholarly journals Feeder Topology Configuration and Application Based on IEC 61850

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4230
Author(s):  
Haotian Ge ◽  
Bingyin Xu ◽  
Xinhui Zhang ◽  
Yongjian Bi ◽  
Zida Zhao

Distribution automation (DA) and Internet of Things (IoT) all need the topology information of power distribution network to support some applications, such as fault diagnosis, network reconfiguration and optimization. IEC 61850 is a general communication model and standard for information exchange between intelligent electronic devices (IEDs). However, it has no mechanism for feeder topology information exchange. This paper solves this problem by developing the corresponding information model. Firstly, a feeder model is established as a container of the equipment along a distribution line. Secondly, logical models, such as terminal and connection nodes, are added to describe the physical connection relationship between the electrical equipment. Taking a circuit breaker as an example, this paper introduces how to add the terminal attribute to an existing logical node (XCBR). The physical connection between the circuit breaker and other electrical equipment is described by adding the logic node LCNN. Then, a new logical node LTPN is added to describe the logical connection between the devices. A new logical node, FTPA, is added to describe the status of the topology analysis and the topology results. Based on these new logical nodes, this paper proposes the mechanism of topology information exchange between IEDs. Three IEDs and the IEEE 13-node model are used to build an experimental environment. The result verifies the effectiveness of this method. More distributed applications can be used to test the validity and interoperability of the proposed model.

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Yu Chen ◽  
Lingyan Sun ◽  
Zonghui Wang ◽  
Jinghua Wang

Distributed control has good real-time performance and can better meet the control requirements of active distribution networks with a large number of distributed generations. Some distributed applications require real-time feeder topology to achieve control. In this paper, the demand for distributed control applications for feeder real-time topology is analyzed. Based on IEC 61850 modeling method, a new cell topology logic node and a new topology slice node are built to express feeder topology. Using the topology information of smart terminal unit (STU) configuration and the current status information of switchgear, based on the depth-first search, the feeder real-time topology identification can be realized, which meets the application requirements of distributed control. The study case verified the effectiveness of the method.


2012 ◽  
Vol E95.B (6) ◽  
pp. 1990-1996
Author(s):  
Seiya ABE ◽  
Sihun YANG ◽  
Masahito SHOYAMA ◽  
Tamotsu NINOMIYA ◽  
Akira MATSUMOTO ◽  
...  

2021 ◽  
Vol 39 (5A) ◽  
pp. 723-737
Author(s):  
Yamur M. Obied ◽  
Thamir M. Abdul Wahhab

The coordination between protective devices is the process of determining the most appropriate timing of power interruption during abnormal conditions in the power system. The aim of this work is to coordinate the protection of the 33/11 kV power distribution substation in Iraq using the CYME 7.1 software package. In this paper overcurrent and earth fault relays are simulated in two cases, with time delay setting and instantaneous setting, to obtain the Time Current Characteristics (TCC) curves for each Circuit Breaker (CB) relay of Al-Karama substation (2×31.5 MVA, 33/11 kV) in Babil distribution network. The short circuit current at each CB is calculated and accordingly, the protection coordination for Al-Karama substation has been simulated. The TCC curves have been obtained in two cases for overcurrent and earth fault relays; in a case with time delay setting and in the case with the instantaneous setting. The setting takes into consideration the short circuit current at the furthest point of the longest outgoing feeder and the shortest outgoing feeder.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2482 ◽  
Author(s):  
Goran Jurišić ◽  
Juraj Havelka ◽  
Tomislav Capuder ◽  
Stjepan Sučić

Visions of energy transition focus on activating end users, meaning that numerous flexible-distribution network-level devices become active participants in power-system operations. This implies a fast, reliable, and secure exchange of data, enabling the distribution-system operators to maintain, or even improve, the quality and delivery of service. With the introduction of the International Electrotechnical Commission (IEC) 61850 standard, the path is set for a single communication topology covering all substation levels. The standard has the potential to change the way substations are designed, built, tested, and maintained. This means that the key segment of the substation, its protection system, will go through a transition period with the end goal of having a digitized substation where all information exchange is performed over an Ethernet communication bus. This paper analyzes the performance impact of the IEC 61850-9-2LE on the protection system. To do this, a laboratory hardware-in-the-loop test setup was developed representing traditional-, hybrid-, and digital-substation topology. The setup serves to simulate faults and create transient waveforms in an extended IEEE 123-node test system, which is then used to detect the reaction times of protection relay devices. To verify the results, a significant number of tests was performed clearly showing the benefits of digitalizing the distribution system.


2020 ◽  
Vol 220 ◽  
pp. 01011
Author(s):  
Igor Nikolaevich Fomin ◽  
Roman Pavlovich Belikov ◽  
Tatyana Anatolyevna Kudinova ◽  
Nailya Kamilevna Miftakhova

Circuit breakers with automatic transfer switches (ATS) are designed in such a way that when the voltage disappears during a short-circuit (SC) in the ring network line, the ATS device is triggered. At the same time, its switch is turned on at short-circuit, then it is turned off with acceleration. Even a shortterm switching on of the automatic transfer switch for a sustained short-circuit leads to emergency situations [1,2]. The electrical equipment of the ring network spare line is exposed to high emergency short-circuit currents, and the consumers powered by the spare transformer are turned off. It is possible to minimize and eliminate the damages caused by the above mentioned cases by inhibiting the switching on of the circuitbreaker of the automatic transfer switch.


2015 ◽  
Vol 2015 ◽  
pp. 1-23 ◽  
Author(s):  
Jun-yi Li ◽  
Yi-ding Zhao ◽  
Jian-hua Li ◽  
Xiao-jun Liu

This paper proposes a modified artificial bee colony optimizer (MABC) by combining bee-to-bee communication pattern and multipopulation cooperative mechanism. In the bee-to-bee communication model, with the enhanced information exchange strategy, individuals can share more information from the elites through the Von Neumann topology. With the multipopulation cooperative mechanism, the hierarchical colony with different topologies can be structured, which can maintain diversity of the whole community. The experimental results on comparing the MABC to several successful EA and SI algorithms on a set of benchmarks demonstrated the advantage of the MABC algorithm. Furthermore, we employed the MABC algorithm to resolve the multilevel image segmentation problem. Experimental results of the new method on a variety of images demonstrated the performance superiority of the proposed algorithm.


Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 334
Author(s):  
Esteban Pulido ◽  
Luis Morán ◽  
Felipe Villarroel ◽  
José Silva

In this paper, a new concept of short-circuit current (SCC) reduction for power distribution systems is presented and analyzed. Conventional fault current limiters (FCLs) are connected in series with a circuit breaker (CB) that is required to limit the short-circuit current. Instead, the proposed scheme consisted of the parallel connection of a current-controlled power converter to the same bus intended to reduce the amplitude of the short-circuit current. This power converter was controlled to absorb a percentage of the short-circuit current from the bus to reduce the amplitude of the short-circuit current. The proposed active short-circuit current reduction scheme was implemented with a cascaded H-bridge power converter and tested by simulation in a 13.2 kV industrial power distribution system for three-phase faults, showing the effectiveness of the short-circuit current attenuation in reducing the maximum current requirement in all circuit breakers connected to the same bus. The paper also presents the design characteristics of the power converter and its associated control scheme.


Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 338
Author(s):  
Leslie Tracy ◽  
Praveen Kumar Sekhar

In this study, a low voltage solid-state circuit breaker (SSCB) was implemented for a DC distribution system using commercially available components. The design process of the high-side static switch was enabled through a voltage bias. Detailed functional testing of the current sensor, high-side switch, thermal ratings, analog to digital conversion (ADC) techniques, and response times of the SSCB was evaluated. The designed SSCB was capable of low-end lighting protection applications and tested at 50 V. A 15 A continuous current rating was obtained, and the minimum response time of the SSCB was nearly 290 times faster than that of conventional AC protection methods. The SSCB was implemented to fill the gap where traditional AC protection schemes have failed. DC distribution systems are capable of extreme faults that can destroy sensitive power electronic equipment. However, continued research and development of the SSCB is helping to revolutionize the power industry and change the current power distribution methods to better utilize clean renewable energy systems.


2015 ◽  
Vol 734 ◽  
pp. 104-108
Author(s):  
Shi Wei Sun ◽  
Xin Tong Liu ◽  
Wei Liu ◽  
Qi Yang

This paper accomplished a system of high-rise building’s fire monitoring system based on CAN bus. It is applied in avoiding the harm of leakage current , over current and short circuit, and protecting electric power distribution circuits and electrical equipment, thus to prevent the occurrence of electrical fire. The monitoring system can detect phase current signal and the leakage current signal, and can display real-time and alarm. It also can proceed network service and complete the distributed remote control and fault diagnosis. Practice shows that the system the characteristics of high precision, safe and reliable, low rate of false positives, easy operation and maintenance, etc .It can satisfy the demand of large high-rise building electrical fire.