scholarly journals Performance Analysis of Integrated Photovoltaic-Thermal and Air Source Heat Pump System through Energy Simulation

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 528
Author(s):  
Sangmu Bae ◽  
Soowon Chae ◽  
Yujin Nam

The concept of zero energy buildings (ZEBs) has recently been actively introduced in the building sector, globally, to reduce energy consumption and carbon emissions. For the implementation of ZEBs, renewable energy systems, such as solar collectors, photovoltaic (PV) systems, and ground source heat pump (GSHP) systems, have been used. The system performance of solar collectors and PV systems are dependent on the weather conditions. A GSHP system requires a large area for boring machines and mud pump machines. Therefore, inhabitants of an existing small-scale buildings hesitate to introduce GSHP systems due to the difficulties in installation and limited construction area. This study proposes an integrate photovoltaic-thermal (PVT) and air source heat pump (ASHP) system for realizing ZEB in an existing small-scale building. In order to evaluate the applicability of the integrated PVT-ASHP system, a dynamic simulation model that combines the PVT-ASHP system model and the building load model based on actual building conditions was constructed. The heating and cooling performances of the system for one year were analyzed using the dynamic simulation model. As the simulation analysis results, the average coefficient of performance (COP) for heating season was 5.3, and the average COP for cooling season was 16.3., respectively. From April to June, the electrical produced by the PVT module was higher than the power consumption of the system and could realize ZEB.

2013 ◽  
Vol 13 (9) ◽  
pp. 1406-1414
Author(s):  
Wang He ◽  
Liu Yong-Shun ◽  
Liu Xiao-Li ◽  
Duan Jin-Hui ◽  
Xue Song ◽  
...  

Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2642 ◽  
Author(s):  
Yi Zhang ◽  
Guanmin Zhang ◽  
Aiqun Zhang ◽  
Yinhan Jin ◽  
Ruirui Ru ◽  
...  

Frost layer on the outdoor air heat exchanger surface in an air-source heat pump (ASHP) can decrease the system coefficient of performance (COP). Although the common defrosting and anti-frosting methods can improve the COP, the periodic defrosting not only reduces the system energy efficiency but also deteriorates the indoor environment. To solve these problems, it is necessary to clearly understand the frosting phenomenon and to achieve the system frost-free operation. This paper focused firstly on the analyses of frosting pathways and frosting maps. Followed by summarizing the characteristics of frost-free technologies. And then the performances of two types of frost-free ASHP (FFASHP) systems were reviewed, and the exergy and economic analysis of a FFASHP heating system were carried out. Finally, the existing problems related to the FFASHP technologies were proposed. Results show that the existing frosting maps need to be further improved. The FFASHP systems can not only achieve continuous frost-free operation but reduce operating cost. And the total COP of the FFASHP heating system is approximately 30–64% higher than that of the conventional ASHP system under the same frosting conditions. However, the investment cost of the FFASHP system increases, and its reliability also needs further field test in a wider frosting environment. In the future, combined with a new frosting map, the control strategy for the FFASHP system should be optimized.


1993 ◽  
Vol 34 (1) ◽  
pp. 33-49 ◽  
Author(s):  
E.A. Arinze ◽  
G.J. Schoenau ◽  
Shahab Sokhansanj ◽  
S.S. Adefila ◽  
S.M. Mumah

2011 ◽  
Vol 374-377 ◽  
pp. 284-287 ◽  
Author(s):  
Yu Wang ◽  
Yu Wen You ◽  
Zhi Gang Zhang

A solar assisted air source heat pump (SAASHP) system is proposed to improve heating performance of air source heat pump (ASHP).The proposed system has been applied in two buildings, a series of experimental investigations were conducted in the both applications, it indicated that the SAASHP system gets better heating performance than ASHP system, the coefficient of performance (COP) gets 10% and 65% increase respectively in two applications. It is also concluded that the ratio of solar collector area to construction area significantly affects the improvement of heating performance in SAASHP system. This work may promote further research and more applications of SAASHP system.


2014 ◽  
Vol 22 (02) ◽  
pp. 1440004 ◽  
Author(s):  
Z. W. HAN ◽  
X. MENG ◽  
M. LIN ◽  
Y. H. ZHANG ◽  
J. YANG ◽  
...  

To solve the problem of the coefficient of performance (COP) decrease and power crunch in cooling dominated South China associated with the long-term usage of ground-source heat pump system (GSHPS), a hybrid ground-air source heat pump system (HGASHPS) with natural cold storage is presented in this paper. The system consists of a GSHP system and compound air-cooled chillers (CACC), which can be operated according to the vapor compression refrigeration cycle or separate type heat pipe natural cycle. The mathematical models of each part of the system were set up and the conversion conditions between operation modes for the system were determined. The transient simulation for HGASHPS with natural cold storage in Nanjing was carried out. The operation characteristics of the systems in operational life were comparatively analyzed. The simulation results indicated that the HGASHPS with natural cold storage could retain the thermal balance of soil temperature field in one year cycle and increase the COP and reliability of the system.


2015 ◽  
Vol 7 (4) ◽  
pp. 468-474
Author(s):  
Karolis Januševičius ◽  
Giedrė Streckienė

Heat pump systems are promising technologies for current and future buildings and this research presents the performance of air source heat pump (ASHP) system. The system was monitored, analysed and simulated using TRNSYS software. The experimental data were used to calibrate the simulation model of ASHP. The specific climate conditions are evaluated in the model. It was noticed for the heating mode that the coefficient of performance (COP) varied from 1.98 to 3.05 as the outdoor temperature changed from –7.0 ºC to +5.0 ºC, respectively. TRNSYS simulations were also performed to predict seasonal performance factor of the ASHP for Vilnius city. It was identified that seasonal performance prediction could be approximately 15% lower if frost formation effects are not included to air-water heat pump simulation model.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2811 ◽  
Author(s):  
Xiang Gou ◽  
Shian Liu ◽  
Yang Fu ◽  
Qiyan Zhang ◽  
Saima Iram ◽  
...  

A household dual source heat pump water heater is proposed to utilize the energy of wastewater and air heat in a bathroom. The heat pump system integrates a wastewater source heat pump (WSHP), air source heat pump (ASHP), and a preheater. This aims at energy saving through recovering the heat of wastewater and ventilation air during the bathing process. The experiment was conducted to verify the feasibility of a dual heat source heat pump water heater system in a bath unit. It is found that the system can achieve an average coefficient of performance (COP) of 4.80 and 4.38 with and without preheater, respectively. At a bath water temperature of 40 °C, a flow rate of 6 L/min, and a room temperature of 26.5 °C, the COP of system can reach 6.08, which shows a significantly promising method for energy saving in-house.


2013 ◽  
Vol 671-674 ◽  
pp. 2141-2144 ◽  
Author(s):  
Qiang Wang ◽  
Feng Zhen Liu ◽  
Li Jun Hou ◽  
Jian Hua Gao

A solar assisted air source heat pump unit is designed. The mathematical model of the unit is established and two hybrid operating conditions of the system are simulated. The simulative studying results shows that in winter the solar assisted air source heat pump unit can make full use of solar energy and the coefficient of performance (COP) of air source heat pump can be improved. In summer the cooling heat of air source heat pump could be recovered to improve the stability of solar hot water collector and the COP of the air source heat pump unit is greatly improved. The performance of solar assisted air source heat pump unit is better than that of with no solar assisted air source heat pump.


Sign in / Sign up

Export Citation Format

Share Document