scholarly journals Performance of Hydrogen Storage Tanks of Type IV in a Fire: Effect of the State of Charge

Hydrogen ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 386-398
Author(s):  
Sergii Kashkarov ◽  
Dmitriy Makarov ◽  
Vladimir Molkov

The use of hydrogen storage tanks at 100% of nominal working pressure (NWP) is expected only after refuelling. Driving between refuellings is characterised by the state of charge SoC <100%. There is experimental evidence that Type IV tanks tested in a fire at initial pressures below 1/3 NWP, leaked without rupture. This paper aims at understanding this phenomenon. The numerical research has demonstrated that the heat transfer from fire through the composite overwrap at storage pressures below NWP/3 is sufficient to melt the polymer liner. This melting initiates hydrogen microleaks through the composite before it loses the load-bearing ability. The fire-resistance rating (FRR) is defined as the time to rupture in a fire of a tank without or with blocked thermally activated pressure relief device. The dependence of a FRR on the SoC is demonstrated for the tanks with defined material properties and volumes in the range of 36–244 L. A composite wall thickness variation is shown to cause a safety issue by reducing the tank’s FRR and is suggested to be addressed by tank manufacturers and OEMs. The effect of a tank’s burst pressure ratio on the FRR is investigated. Thermal parameters of the composite wall, i.e., decomposition heat and temperatures, are shown in simulations of a tank failure in a fire to play an important role in its FRR.

1965 ◽  
Vol 16 (5) ◽  
pp. 717-721 ◽  
Author(s):  
C.Walton Lillehei ◽  
Anatolio B. Cruz ◽  
Irwin Johnsrude ◽  
Robert D. Sellers

2021 ◽  
Author(s):  
Jun Li ◽  
Xiang Li ◽  
Jiepu Li ◽  
Baodi Zhao ◽  
Chunlin Gu ◽  
...  

Abstract As important equipment in the entire hydrogen industry chain, composite hydrogen storage cylinders for transportation have developed rapidly in recent years. The fire test is used to verify the explosion resistance of gas cylinders under specified fire conditions. Compared to steel gas cylinder, composite gas cylinder is more dangerous in the fire condition. The wound layer, as the main pressure-bearing structure of the composite hydrogen storage cylinder, is inflammable. In the case of fire, the mechanical properties of the cylinder will degrade quickly due to the high temperature. If the gas inside the cylinder cannot be discharged in time, the cylinder explosion will occur. Currently, some relevant standards or standard drafts have been drawn up by the international organizations, which are useful for formulating Chinese standard for hydrogen storage cylinders for transportation. The applicable scope of the standards was discussed in this paper, such as composite cylinder type, working pressure, nominal volume and design life, etc. The fire test methods of composite gas cylinders in various standards were compared and analyzed, such as experiment method, cylinder placement method, cylinder filling requirements, fuel selection, fire source setting, temperature measurement requirements, and qualified indicators, etc. Finally, the challenges for development of composite hydrogen storage cylinders and compressed hydrogen storage systems in China were proposed.


2018 ◽  
Vol 165 (13) ◽  
pp. A3164-A3168 ◽  
Author(s):  
Noemí Aguiló-Aguayo ◽  
Thomas Bechtold

Sign in / Sign up

Export Citation Format

Share Document