scholarly journals Alteration within the Hippocampal Volume in Patients with LHON Disease—7 Tesla MRI Study

2020 ◽  
Vol 10 (1) ◽  
pp. 14
Author(s):  
Cezary Grochowski ◽  
Kamil Jonak ◽  
Marcin Maciejewski ◽  
Andrzej Stępniewski ◽  
Mansur Rahnama-Hezavah

Purpose: The aim of this study was to assess the volumetry of the hippocampus in the Leber’s hereditary optic neuropathy (LHON) of blind patients. Methods: A total of 25 patients with LHON were randomly included into the study from the national health database. A total of 15 patients were selected according to the inclusion criteria. The submillimeter segmentation of the hippocampus was based on three-dimensional spoiled gradient recalled acquisition in steady state (3D-SPGR) BRAVO 7T magnetic resonance imaging (MRI) protocol. Results: Statistical analysis revealed that compared to healthy controls (HC), LHON subjects had multiple significant differences only in the right hippocampus, including a significantly higher volume of hippocampal tail (p = 0.009), subiculum body (p = 0.018), CA1 body (p = 0.002), hippocampal fissure (p = 0.046), molecular layer hippocampus (HP) body (p = 0.014), CA3 body (p = 0.006), Granule Cell (GC) and Molecular Layer (ML) of the Dentate Gyrus (DG)–GC ML DG body (p = 0.003), CA4 body (p = 0.001), whole hippocampal body (p = 0.018), and the whole hippocampus volume (p = 0.023). Discussion: The ultra-high-field magnetic resonance imaging allowed hippocampus quality visualization and analysis, serving as a powerful in vivo diagnostic tool in the diagnostic process and LHON disease course assessment. The study confirmed previous reports regarding volumetry of hippocampus in blind individuals.

2001 ◽  
Vol 49 (3) ◽  
pp. 275-284
Author(s):  
Zs. Petrási ◽  
R. Romvári ◽  
G. Bajzik ◽  
B. Fenyves ◽  
I. Repa ◽  
...  

A dynamic magnetic resonance imaging (MRI) method was developed for in vivo examination of the pig heart. Measurements were carried out on 15 meat-type pigs of different liveweight using a 1.5 T equipment. Inhalation anaesthesia was applied, then data acquisition was synchronised by ECG gating. Depending on the heart rate and heart size, in each case 8 to 10 slices and in each slice 8 to 14 phases were acquired prospectively according to one heart cycle. During the post-processing of the images the left and the right ventricular volumes were determined. The values measured at 106 kg liveweight are 2.5 times higher than those obtained at 22 kg, while the ejection fractions are equal. The calculated cardiac output values were 3.5 l (22 kg, 132 beats/min.), and 6.0 l (106 kg, 91 beats/min.), respectively. After measuring the wall thickness, the contraction values were also determined for the septum (70%), and for the anterior (61%), posterior (41%) and lateral (54%) walls of the left ventricle. Three-dimensional animated models of the ventricles were constructed. Based on the investigations performed, the preconditioning, the anaesthetic procedure, the specific details of ECG measurement and the correct MR imaging technique were worked out.


1999 ◽  
Vol 121 (6) ◽  
pp. 650-656 ◽  
Author(s):  
F. T. Sheehan ◽  
F. E. Zajac ◽  
J. E. Drace

Improper patellar tracking is often considered to be the cause of patellar-femoral pain. Unfortunately, our knowledge of patellar-femoral-tibial (knee) joint kinematics is severely limited due to a lack of three-dimensional, noninvasive, in vivo measurement techniques. This study presents the first large-scale, dynamic, three-dimensional, noninvasive, in vivo study of nonimpaired knee joint kinematics during volitional leg extensions. Cine-phase contrast magnetic resonance imaging was used to measure the velocity profiles of the patella, femur, and tibia in 18 unimpaired knees during leg extensions, resisted by a 34 N weight. Bone displacements were calculated through integration and then converted into three-dimensional orientation angles. We found that the patella displaced laterally, superiorly, and anteriorly as the knee extended. Further, patellar flexion lagged knee flexion, patellar tilt was variable, and patellar rotation was fairly constant throughout extension.


Author(s):  
Karen Perta ◽  
Eileen Kalmar ◽  
Youkyung Bae

Purpose The aim of the study was to update our information regarding the salpingopharyngeus (SP) muscle using cadaveric and in vivo magnetic resonance imaging (MRI) data. Primary objectives were to (a) observe the presence/absence of the muscle and (b) quantify and describe its dimensions and course. Method SP specimens from 19 cadavers (10 women, nine men) were analyzed. Following head bisection, measurements of SP, including width of the cartilaginous attachment (CW) and width of the superior muscle base (SMW), were taken before and after removal of the overlying mucosa. In addition, SP was analyzed in 15 healthy subjects (eight men, seven women) using high-resolution three-dimensional MRI data. CW and SMW measures were replicated in the paraxial MRI view. Results The presence of the salpingopharyngeal fold and muscle was confirmed bilaterally in all cadaveric and living subjects. Following mucosa removal, mean cadaveric CW and SMW measurements were 5.6 and 3.8 mm, respectively. Mean in vivo CW and SMW were 6.1 and 3.7 mm, respectively. Results from the hierarchical regression analyses revealed that, in both cadaveric and living groups, SMW is dependent on the relationship between age and body weight, after controlling for sex. Conclusions The salpingopharyngeal fold and SP muscle are always present bilaterally and can be quantified at the superior origin using both cadaveric and in vivo three-dimensional MRI data. Though both the superior origin and inferior course of SP are highly variable, the size of the SP muscle is dependent on characteristics known to affect muscle fibers, such as the relationship between age and body weight. Given the consistent and quantifiable presence of the SP muscle, its potential role in velopharyngeal function for speech and swallowing is reconsidered. Supplemental Material https://doi.org/10.23641/asha.14347859


1999 ◽  
Vol 24 (2) ◽  
pp. 245-248 ◽  
Author(s):  
T. NAKAMURA ◽  
Y. YABE ◽  
Y. HORIUCHI

In vivo dynamic changes in the interosseous membrane (IOM) during forearm rotation were studied using magnetic resonance imaging (MRI). The right forearms of 20 healthy volunteers were examined in five different rotational positions. Axial slices were obtained at the proximal quarter, the middle and the distal quarter of the forearm. The changes in shape of the IOM during rotation were observed in an axial MR plane. For each image, we measured the interosseous distance and the length of the interosseous membrane. Images of the tendinous and membranous parts of the IOM could be differentiated by thickness. There were minimal dynamic changes in the tendinous part on the MRI while the membranous part showed numerous changes during rotation. The interosseous distance and the length of the interosseous membrane were maximum from a neutral to a slightly supinated position. The tendinous part is considered to be taut during rotation to provide stability between the radius and the ulna, but the membranous part which is soft, thin and elastic, allows smooth rotation.


Author(s):  
JC Lau ◽  
J DeKraker ◽  
KW MacDougall ◽  
H Joswig ◽  
AG Parrent ◽  
...  

Background: The hippocampus can be divided longitudinally into the head, body, and tail; and unfolded medial-to-laterally into the subiculum, cornu ammonis (CA) sectors, and the dentate gyrus. Ultra-high field (≥ 7 Tesla; 7T) magnetic resonance imaging (MRI) enables submillimetric visualization of these hippocampal substructures which could be valuable for surgical targeting. Here, we assess the feasibility of using 7T MRI in conjunction with a novel computational unfolding method for image-based stereotactic targeting of hippocampal substructures. Methods: 53 patients with drug-resistant epilepsy were identified undergoing first-time implantation of the hippocampus. An image processing pipeline was created for computationally transforming post-operative electrode contact locations into our hippocampal coordinate system. Results: Of 178 implanted hippocampal electrodes (88 left; 49.4%), 25 (14.0%) were predominantly in the subiculum, 85 (47.8%) were in CA1, 23 (12.9%) were in CA2, 18 (10.1%) were in CA3/CA4, and 27 (15.2%) were in dentate gyrus. Along the longitudinal axis, hippocampal electrodes were most commonly implanted in the body (92; 51.7%) followed by the head (86; 48.3%). Conclusions: 7T MRI enables high-resolution anatomical imaging on the submillimeter scale in in vivo subjects. Here, we demonstrate the utility of 7T imaging for identifying the relative location of SEEG electrode implantations within hippocampal substructures for the invasive investigation of epilepsy.


2020 ◽  
Vol 13 ◽  
pp. 175628642094798
Author(s):  
Michela Leocadi ◽  
Elisa Canu ◽  
Davide Calderaro ◽  
Davide Corbetta ◽  
Massimo Filippi ◽  
...  

The purpose of the present review is to provide an update of the available recent scientific literature on the use of magnetic resonance imaging (MRI) in Alzheimer’s disease (AD). MRI is playing an increasingly important role in the characterization of the AD signatures, which can be useful in both the diagnostic process and monitoring of disease progression. Furthermore, this technique is unique in assessing brain structure and function and provides a deep understanding of in vivo evolution of cerebral pathology. In the reviewing process, we established a priori criteria and we thoroughly searched the very recent scientific literature (January 2018–March 2020) for relevant articles on this topic. In summary, we selected 73 articles out of 1654 publications retrieved from PubMed. Based on this selection, this review summarizes the recent application of MRI in clinical trials, defining the predementia stages of AD, the clinical utility of MRI, proposal of novel biomarkers and brain regions of interest, and assessing the relationship between MRI and cognitive features, risk and protective factors of AD. Finally, the value of a multiparametric approach in clinical and preclinical stages of AD is discussed.


Sign in / Sign up

Export Citation Format

Share Document