scholarly journals Effect of Dentin Bonding Agents, Various Resin Composites and Curing Modes on Bond Strength to Human Dentin

Materials ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3395
Author(s):  
Rene Steiner ◽  
Daniel Edelhoff ◽  
Bogna Stawarczyk ◽  
Herbert Dumfahrt ◽  
Isabel Lente

This study investigated the influence of several dentin bonding agents, resin composites and curing modes on push-out bond strength to human dentin. 360 extracted caries-free third molars were prepared, cut into slices, embedded in epoxy resin and perforated centrally. One half of the specimens (180) were treated by using one-step adhesive systems and the other half (180) with multi-step adhesive systems. Subsequently, the cavities were filled with either universal, flowable or bulk-fill resin composite according to the manufactures’ product line and cured with either turbo or soft start program. After storage the push-out test was performed. The data was analyzed using Kolmogorov-Smirnov, three- and one-way ANOVA followed by the Scheffé post-hoc test, unpaired two-sample t-test (p < 0.05). The strongest influence on push-out bond strength was exerted by the resin composite type (partial eta squared ηP2 = 0.505, p < 0.001), followed by the adhesive system (ηP2 = 0.138, p < 0.001), while the choice of the curing intensity was not significant (p = 0.465). The effect of the binary or ternary combinations of the three parameters was significant for the combinations resin composite type coupled adhesive system (ηP2 = 0.054, p < 0.001), only. The flowable resin composites showed predominantly mixed, while the universal and bulk-fill resin composite showed adhesive failure types. Cohesive failure types were not observed in any group. Multi-step adhesive systems are preferable to one-step adhesive systems due to their higher bond strength to dentin. Flowable resin composites showed the highest bond strength and should become more important as restoration material especially in cavity lining. The use of a soft start modus for polymerization of resin composites does not enhance the bond strength to dentin.

2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Rodrigo Vieira Caixeta ◽  
Ricardo Danil Guiraldo ◽  
Edmilson Nobumitu Kaneshima ◽  
Aline Silvestre Barbosa ◽  
Cassiana Pedrotti Picolotto ◽  
...  

The aim of this study was to evaluate the bond strengths of composite restorations made with different filler amounts and resin composites that were photoactivated using a light-emitting diode (LED). Thirty bovine incisors were selected, and a conical cavity was prepared in the facial surface of each tooth. All preparations were etched with Scotchbond Etching Gel, the Adper Scotchbond Multipurpose Plus adhesive system was applied followed by photoactivation, and the cavities were filled with a single increment of Filtek Z350 XT, Filtek Z350 XT Flow, or bulk-fill X-tra fil resin composite (n= 10) followed by photoactivation. A push-out test to determine bond strength was conducted using a universal testing machine. Data (MPa) were submitted to Student’st-test at a 5% significance level. After the test, the fractured specimens were examined using an optical microscope under magnification (10x). Although all three composites demonstrated a high prevalence of adhesive failures, the bond strength values of the different resin composites photoactivated by LED showed that the X-tra fil resin composite had a lower bond strength than the Filtek Z350 XT and Filtek Z350 XT Flow resin composites.


2021 ◽  
Vol 46 (1) ◽  
pp. 45-53
Author(s):  
HA El-Deeb ◽  
EH Mobarak

Clinical Relevance High-viscosity glass-ionomer cements (HVGICs) used with atraumatic restorative treatment can be repaired with light- or self-cured adhesive systems; however, the repair bond strength of two-step, self-etching and one-step adhesives in the light-cure mode surpass one-step self-cure adhesives. Working on a feasible self-cure approach in the absence of such in rural areas as well as in war zones is of prime importance. SUMMARY Objectives: Despite the success rate of high-viscosity glass-ionomer cements (HVGICs) used in atraumatic restorative treatment (ART) restorations, partial or bulk fracture of the proximal portion has been recorded to be one of the main causes of proximal restoration failures. Repair of these restorative materials requires a practical solution, especially in cases where there is a lack of electricity. Thus, the purpose of this study was to evaluate the repair microshear bond strength (μSBS) of three HVGICs using a resin composite in association with adhesive systems having different curing modes (ie, light- vs self-curing mode). Methods and Materials: A total of 105 discs (12 mm in diameter and 2 mm thick) of three HVGICs: GC Fuji IX GP Fast (GC Corporation, Tokyo, Japan); Fuji IX GP glass-ionomer cement containing chlorhexidine (GC Corporation, Tokyo, Japan); and ChemFil Rock zinc-reinforced HVGIC (Dentsply De-Trey GmbH, Konstanz, Germany) were prepared. Each specimen was divided into three horizontal sections, according to the tested adhesive system or curing mode: Clearfil SE Bond 2 (two-step, self-etch adhesive); (Kuraray Noritake Dental Inc., Tokyo, Japan) in light-cure mode; Clearfil Universal Bond (one-step, self-etch adhesive); (Kuraray Noritake Dental Inc., Tokyo, Japan) in light-cure mode; or Clearfil Universal Bond (one-step, self-etch adhesive); (Kuraray Noritake Dental Inc., Tokyo, Japan) in self-cure mode, mixing it with Clearfil DC Activator (Kuraray Noritake Dental Inc., Tokyo, Japan). A resin composite microcylinder was bonded to each horizontal section of each specimen using starch tubes. The bonded discs were stored in artificial saliva at 37°C for 24 hours. A μSBS test was conducted using a universal testing machine, while failure modes were determined using scanning electron microscopy. Data were statistically analyzed using two-way analysis of variance (ANOVA), one-way ANOVA, and Bonferroni post hoc tests (α=0.05). Results: Two-way ANOVA revealed a statistically significant effect for the adhesive systems (p&lt;0.01) and not for the HVGICs (p=0.05) nor their interactions (p=0.99). When using Clearfil SE Bond 2 and Clearfil Universal in a light-cure mode, significantly higher μSBS values were found when compared with Clearfil Universal in a self-cure mode. Conclusions: The three tested HVGICs can be successfully repaired using two-step or one-step self-etch adhesive systems. The one-step self-etch adhesive system in light-cure mode is preferred when compared with the self-cure mode.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Katrin Zumstein ◽  
Anne Peutzfeldt ◽  
Adrian Lussi ◽  
Simon Flury

This study investigated the effect of SnCl2/AmF pretreatment on short- and long-term bond strength of resin composite to eroded dentin mediated by two self-etch, MDP-containing adhesive systems. 184 dentin specimens were produced from extracted human molars. Half the specimens (n=92) were artificially eroded, and half were left untreated. For both substrates, half the specimens were pretreated with SnCl2/AmF, and half were left untreated. The specimens were treated with Clearfil SE Bond or Scotchbond Universal prior to application of resin composite. Microtensile bond strength (μTBS) was measured after 24 h or 1 year. Failure mode was detected and EDX was performed. μTBS results were statistically analyzed (α=0.05). μTBS was significantly influenced by the dentin substrate (eroded < noneroded dentin) and storage time (24 h > 1 year; p<0.0001) but not by pretreatment with SnCl2/AmF or adhesive system. The predominant failure mode was adhesive failure at the dentin-adhesive interface. The content of Sn was generally below detection limit. Pretreatment with SnCl2/AmF did not influence short- and long-term bond strength to eroded dentin. Bond strength was reduced after storage for one year, was lower to eroded dentin than to noneroded dentin, and was similar for the two adhesive systems.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


2009 ◽  
Vol 03 (04) ◽  
pp. 290-296 ◽  
Author(s):  
André Luís Faria-e-Silva ◽  
Mayra Melo Fabião ◽  
Ravana Angelini Sfalcin ◽  
Murilo de Souza Meneses ◽  
Paulo César Freitas Santos-Filho ◽  
...  

ABSTRACTObjectives: The aim of this study was to evaluate the bond strength of one-step adhesive systems to dry or moist dental substrate.Methods: Thirty human third molars were sectioned into two halves, in the mesio-distal direction, parallel to the long axis of the tooth. Each half was embedded in a polystyrene resin cylinder so that the buccal/lingual surface remained exposed. This exposed surface was abraded to obtain both flat exposed enamel and dentin. The samples were randomly allocated according to the adhesive system (Xeno III, Adper Prompt and iBond) and moisture condition (dry and moist). The substrates were air-dried for 30 s for dry condition, while the moist substrates were re-wet with 2.5 µl of distilled water after drying. After the adhesive procedures, two resin composite cylinders were build-up on dentin and enamel substrates, totaling four per sample. A shear load was applied to the samples at a crosshead speed of 0.5 mm/min until failure. Data were statistically analyzed by three-way ANOVA and the Tukey test (α=0.05).Results: The evaluated one-step adhesives showed higher bond strength to dentin than enamel. The iBond presented better bond performance to moist substrate and Xeno III to dry substrate. The moisture condition did not interfere in the performance of Adper Prompt. The Xeno III and iBond presented higher bond strength than the other adhesives to both dry and moist substrates.Conclusions: The moisture condition of substrate interfered in the performance of one-step selfetching adhesives and the best moisture condition was material dependent. (Eur J Dent 2009;3:290-296)


2017 ◽  
Vol 31 (4) ◽  
pp. 158
Author(s):  
Veridiana Camilotti ◽  
Virgínia Bosquiroli ◽  
Máx Dobrovolski ◽  
Mario Alexandre Coelho Sinhoretic ◽  
Priscilla Busatoa Do Monte Ribeiro ◽  
...  

OBJECTIVE: The aim of this study was to evaluate the bond strength (BS) of different self-etching adhesive systems to bovine dentin.METHODS: For this purpose, 50 teeth were flattened with silicon carbide abrasive papers and randomly divided into 5 groups: SB – Single Bond Plus; Group AEO – Adper Easy One; Group ADH – AdheSE; Group ASE – Adper SE Plus and Group Clear – Clear Fill. After adhesive system application, 5 Tygon cylinders (1.8 mm×2 mm) were placed on the vestibular surface of each tooth, filled with resin composite (Filtek Z350) and light activated. Three composite resin cylinders were fabricated for each bovine crown, one being located in the incisal region, one in the middle third and one in the cervical region, totaling 30 composite resin test specimens (TS) for each group. The TS were submitted to the microshear bond strength test in a Universal Test Machine  Kratos), at a cross-head speed of 0.5 mm/min.RESULTS: The BS was calculated and analyzed by ANOVA (one-way) and Tukey’s test (p<0.05). The highest BS values were obtained in Group SB and there were no significant differences between the adhesive systems tested in the middle and cervical thirds. In the fracture type analysis it was found that adhesive failure was dominant for all groups.CONCLUSION: The conventional two-step adhesive system SB presented the highest bond strength mean to bovine dentin for all the regions.


2016 ◽  
Vol 27 (6) ◽  
pp. 705-711 ◽  
Author(s):  
Karina Kato Carneiro ◽  
Marcia Margarete Meier ◽  
Clenilton Costa dos Santos ◽  
Adeilton Pereira Maciel ◽  
Ceci Nunes Carvalho ◽  
...  

Abstract To evaluate the effect of incorporating niobium phosphate bioactive glass (NbG) into commercial etch-and-rinse adhesive systems, with and without silane, on their degree of conversion (DC) (%) and microtensile bond strength (μTBS). The NbG micro-filler was added to two etch-and-rinse adhesive systems: One Step (OS) and Prime & Bond (PB) at 40% concentration. The following groups were formed: control without glass addition OS; addition of unsilanized NbG (OSNbG); addition of silanized NbG (OSNbGS); control without glass PB; addition of unsilanized NbG (PBNbG); addition of silanized NbG (PBNbGS). The DC was determined using total Fourier spectroscopy reflection (FTIR/ATR). For μTBS testing, 48 human third molars (n=8) were restored and sliced to obtain specimens (0.8 mm2) and they were tested at two different time intervals: immediately and after 6 months. The fracture mode was evaluated with a stereoscopic loupe (40×) and by scanning electron microscopy (SEM). The data were subjected to ANOVA and Tukey tests (a=0.05). NbG addition did not compromise the adhesive system DC values (p>0.05). Furthermore, the NbG added to the adhesive systems did not affect μTBS values (p>0.05). Fracture occurred predominantly at the dentin-adhesive interface. NbG bioactive glass did not affect the DC or microtensile bond strength results.


2020 ◽  
Vol 14 (1) ◽  
pp. 408-415
Author(s):  
Isabella A. Gomes ◽  
Mário G. N. Gomes ◽  
Flávia L. B. Amaral ◽  
Fabiana M. G. França ◽  
Roberta T. Basting ◽  
...  

Objective: This study investigated whether different aging protocols have effects on the bond strength of total-etch and self-etch adhesive systems to dentin substrate. Methods: Molars were sectioned exposing the dentin, which was submitted to restorative procedures using two-step total-etch (ASB, Adper SingleBond2), two-step self-etch (CLF, Clearfil SEBond), or one-step self-etch (OPT, Optibond All-in-One) system and resin composite. The obtained blocks were sectioned to result in sticks to be submitted to bond strength and failure mode tests after 24h storage in distilled water (DW), or 180-day aging protocols in DW, artificial saliva (AS), citric acid (CA), or thermal cycling (TC). The types of failures were classified as adhesive, cohesive in dentin, cohesive in composite resin, and mixed. Data were analyzed using ANOVA followed by Tukey’s test (α=5%). The failure modes were descriptive under the relative frequencies form. Results: It was observed that ASB presented the higher bond strength(p<0.05), while CLF and OPT did not demonstrate differences between them(p>0.05) after 24h. The bond strength obtained with ASB significantly overcame that of OPT when stored in DW or AS for 180 days (p<0.001). In these storing mediums, ASB did not differ from CLF(p>0.05), while in CA or TC the values of CLF were significantly lower (p<0.001). In TC aging, the values presented by OPT did not differ from ASB(p>0.05), both of which had higher values than CLF(p<0.05). The predominant failure mode was adhesive. Conclusion: For the two-step total-etch and two-step self-etch adhesives, the influence of aging in AS and TC was equivalent to that of storage in DW. The most deleterious effects occurred in CA, a situation in which self-etch adhesives displayed worse performance than the conventional type.


2007 ◽  
Vol 8 (7) ◽  
pp. 46-53 ◽  
Author(s):  
Rubens Nazareno Garcia ◽  
Mario Fernando de Goes ◽  
Marcelo Giannini

Abstract Aim The objective of this study was to evaluate the bond strength of self-etching adhesive systems one week and one year after storage in water. Methods and Materials Fragments from the buccal surfaces of 45 bovine teeth were prepared (12 mm in length X 5 mm in width X 1.0 mm in thickness). Dentin surfaces were wet-abraded with 600-grit SiC paper to create a standardized smear layer. Samples were randomly assigned to 18 experimental groups (n=5), according to nine adhesive systems tested (Single Bond; Adper Prompt L-Pop; iBond; One-Up Bond F; Xeno III; Clearfil SE Bond; Optibond Solo Plus SE; Tyrian SPE/One-Step Plus; and UniFil Bond) and two waterstorage times (one week and one year). Adhesives were applied according to the manufacturers’ instructions. Z250 composite was applied into the molds to fill up the internal diameter volume of a Tygon tubing mold (1.0 mm high / 0.7 mm internal diameter). Micro-shear bond strengths were determined using an apparatus attached to an Instron Universal Testing Machine (0.5 mm/min). Data were statistically analyzed using a twoway analysis of variance (ANOVA) and the Tukey's test (5%). Results One year after water storage the dentin bond strength of all adhesive systems reduced significantly, except for One-Up Bond F. Conclusion Water-storage time decreased the bond strength for most dentin bonding agents tested. Citation Garcia RN, de Goes MF, Giannini M. Effect of Water Storage on Bond Strength of Self-etching Adhesives to Dentin. J Contemp Dent Pract 2007 November; (8)7:046-053.


Sign in / Sign up

Export Citation Format

Share Document