scholarly journals Special Issue “Advances in Artificial and Biological Membranes: Mechanisms of Ionic Sensitivity, Ion-Sensor Designs, and Applications for Ion Measurement”

Membranes ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 427
Author(s):  
Andrzej Lewenstam ◽  
Krzysztof Dołowy

Ion sensors, conventionally known as ion-selective membrane electrodes, were devised 100 years ago with the invention of a pH electrode with a glass membrane (in 1906 Cremer, in 1909 Haber and Klemensiewicz) [...]

Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4213
Author(s):  
Seong-Kun Cho ◽  
Won-Ju Cho

In this study, a highly sensitive and selective sodium ion sensor consisting of a dual-gate (DG) structured silicon nanowire (SiNW) field-effect transistor (FET) as the transducer and a sodium-selective membrane extended gate (EG) as the sensing unit was developed. The SiNW channel DG FET was fabricated through the dry etching of the silicon-on-insulator substrate by using electrospun polyvinylpyrrolidone nanofibers as a template for the SiNW pattern transfer. The selectivity and sensitivity of sodium to other ions were verified by constructing a sodium ion sensor, wherein the EG was electrically connected to the SiNW channel DG FET with a sodium-selective membrane. An extremely high sensitivity of 1464.66 mV/dec was obtained for a NaCl solution. The low sensitivities of the SiNW channel FET-based sodium ion sensor to CaCl2, KCl, and pH buffer solutions demonstrated its excellent selectivity. The reliability and stability of the sodium ion sensor were verified under non-ideal behaviors by analyzing the hysteresis and drift. Therefore, the SiNW channel DG FET-based sodium ion sensor, which comprises a sodium-selective membrane EG, can be applied to accurately detect sodium ions in the analyses of sweat or blood.


1982 ◽  
Vol 136 ◽  
pp. 399-401 ◽  
Author(s):  
Masaru Yamauchi ◽  
Akinori Jyo ◽  
Nobuhiko Ishibashi

2008 ◽  
Vol 139 (12) ◽  
pp. 1439-1445 ◽  
Author(s):  
Ahmad Soleymanpour ◽  
Bahram Garaili ◽  
S. Masoud Nabavizadeh

Author(s):  
Patrick Magee ◽  
Mark Tooley

A blood gas machine has electrodes to measure pH, pCO2 and pO2 and often measures Hb and some biochemistry as well [King et al. 2000]. Derived values from such a device include O2 saturation, O2 content, bicarbonate, base excess and total CO2. This is the Clarke electrode described in the previous section on gas analysers and is suitable for both respiratory and blood O2 analysis. A pH unit has been defined in Chapter 1 as. In words, this can be described as ‘the negative logarithm, to base ten, of the hydrogen ion concentration’. The physical principle on which the pH electrode is based depends on the fact that when a membrane separates two solutions of different [H+], a potential difference exists across the membrane. In a pH electrode, such a membrane is usually made of glass and the development of a potential difference between the two solutions is thought to be due to the migration of H+ into the glass matrix. If one solution consists of a standard [H+], the pH of the other solution can be estimated by measurement of the potential difference between them. The glass membrane used is selectively permeable to H+. No current flows in this device, which does not wear out, in contrast to the Clark electrode, in which current does flow and that does need periodic replacement. The pH measurement system is shown diagrammatically in Figure 17.1. It consists of two half cells. In one half it has an Ag/AgCl electrode and in the other a Hg/HgCl2 (calomel) electrode. Each electrode maintains a fixed electrical potential. The Ag/AgCl electrode is surrounded by a buffer solution of known pH, surrounded by the pH sensitive glass. Outside the glass membrane is the test solution, usually blood, whose pH is to be measured. It is the potential difference across the glass, between these two solutions, which is variable. The blood or other solution is separated from the calomel electrode by a porous plug and a potassium chloride salt bridge to minimise KCl diffusion. The potential difference across the system is about 60 mV per unit of pH change at 37◦C.


1997 ◽  
Vol 9 (7) ◽  
pp. 549-553 ◽  
Author(s):  
Xinhao Yang ◽  
Naresh Kumar ◽  
Hua Chi ◽  
D. Brynn Hibbert ◽  
Peter W. Alexander

Sign in / Sign up

Export Citation Format

Share Document