scholarly journals Rapid Determination of Active Compounds and Antioxidant Activity of Okra Seeds Using Fourier Transform Near Infrared (FT-NIR) Spectroscopy

Molecules ◽  
2018 ◽  
Vol 23 (3) ◽  
pp. 550 ◽  
Author(s):  
◽  
◽  
◽  
◽  
◽  
...  
2016 ◽  
Vol 8 (23) ◽  
pp. 4584-4589 ◽  
Author(s):  
Longhui Ma ◽  
Zhimin Zhang ◽  
Xingbing Zhao ◽  
Sufeng Zhang ◽  
Hongmei Lu

NIR spectroscopy coupled with chemometric methods for rapid quantification of total polyphenols content and antioxidant activity inDendrobium officinale.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Mohd Yusop Nurida ◽  
Dolmat Norfadilah ◽  
Mohd Rozaiddin Siti Aishah ◽  
Chan Zhe Phak ◽  
Syafiqa M. Saleh

The analytical methods for the determination of the amine solvent properties do not provide input data for real-time process control and optimization and are labor-intensive, time-consuming, and impractical for studies of dynamic changes in a process. In this study, the potential of nondestructive determination of amine concentration, CO2 loading, and water content in CO2 absorption solvent in the gas processing unit was investigated through Fourier transform near-infrared (FT-NIR) spectroscopy that has the ability to readily carry out multicomponent analysis in association with multivariate analysis methods. The FT-NIR spectra for the solvent were captured and interpreted by using suitable spectra wavenumber regions through multivariate statistical techniques such as partial least square (PLS). The calibration model developed for amine determination had the highest coefficient of determination (R2) of 0.9955 and RMSECV of 0.75%. CO2 calibration model achieved R2 of 0.9902 with RMSECV of 0.25% whereas the water calibration model had R2 of 0.9915 with RMSECV of 1.02%. The statistical evaluation of the validation samples also confirmed that the difference between the actual value and the predicted value from the calibration model was not significantly different and acceptable. Therefore, the amine, CO2, and water models have given a satisfactory result for the concentration determination using the FT-NIR technique. The results of this study indicated that FT-NIR spectroscopy with chemometrics and multivariate technique can be used for the CO2 solvent monitoring to replace the time-consuming and labor-intensive conventional methods.


2014 ◽  
Vol 07 (06) ◽  
pp. 1450012 ◽  
Author(s):  
Qin Dong ◽  
Hengchang Zang ◽  
Lixuan Zang ◽  
Aihua Liu ◽  
Yanli Shi ◽  
...  

Hyaluronic acid (HA) concentration is an important parameter in fermentation process. Currently, carbazole assay is widely used for HA content determination in routine analysis. However, this method is time-consuming, environment polluting and has the risk of microbial contamination, as well as the results lag behind fermentation process. This paper attempted the feasibility to predict the concentration of HA in fermentation broth by using near infrared (NIR) spectroscopy in transmission mode. In this work, a total of 56 samples of fermentation broth from 7 batches were analyzed, which contained HA in the range of 2.35–9.69 g/L. Different data preprocessing methods were applied to construct calibration models. The final optimal model was obtained with first derivative using Savitzky–Golay smoothing (9 points window, second-order polynomial) and partial least squares (PLS) regression with leave-one-block-out cross validation. The correlation coefficient and Root Mean Square Error of prediction set is 0.98 and 0.43 g/L, respectively, which show the possibility of NIR as a rapid method for microanalysis and to be a promising tool for a rapid assay in HA fermentation.


2020 ◽  
Vol 28 (5-6) ◽  
pp. 344-350
Author(s):  
M Gonçalves ◽  
NT Paiva ◽  
JM Ferra ◽  
J Martins ◽  
F Magalhães ◽  
...  

Near infrared (NIR) spectroscopy is a fast and reliable technique for assessing properties of amino resins. One important property that defines the cost and performance of these resins is the solids content (SC). This work studied the prediction of SC of amino resins by combining NIR spectroscopy with partial least squares (PLS) regression. A total of 990 industrial NIR spectra of amino resins were obtained and split randomly by a ratio of 2/3 for calibration and 1/3 for validation. The best model achieved a root mean-square error of prediction (RMSEP) of 0.32% (m/m) and a coefficient of determination of prediction ([Formula: see text]) of 81%. standard normal variate (SNV) was found to be the NIR pre-processing that provided the best results for model construction. Addition of water to two amino resins showed that the NIR model does not respond to the water addition, despite water making great contribution to the SC value. An inference that can be obtained from this is that the NIR model of amino resins uses NIR properties of amino resins that relate to the SC and from there predict the most probable SC, instead of looking at all the components that affect the SC of amino resins.


Author(s):  
Karla Beltrame ◽  
Thays Gonçalves ◽  
Paulo Março ◽  
Sandra Gomes ◽  
Makoto Matsushita ◽  
...  

This work shows an alternative methodology based on a portable near-infrared (NIR) spectroscopy coupled to independent components analysis (ICA) in a pseudo-univariate calibration way to determine total anthocyanins (TA) concentration and antioxidant activity (AA) in whole grape juice. To this, the scores proportions more related to TA and AA were plotted against TA and AA obtained by its respective references methodology to build pseudo-univariate calibration models with correlation coefficients of 0.9699 and 0.9814, respectively. From the results, it is possible the suggestion that NIR spectra coupled to ICA enable to overcome interferences using first-order data and work properly when there is enough selectivity for the analyte profile in the sample data.