scholarly journals Design of a Microwave Power Detection System in the 5G-Communication Frequency Band

Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2674
Author(s):  
Qingying Ren ◽  
Wen Zuo ◽  
Jie Xu ◽  
Leisheng Jin ◽  
Wei Li ◽  
...  

At present, the proposed microwave power detection systems cannot provide a high dynamic detection range and measurement sensitivity at the same time. Additionally, the frequency band of these detection systems cannot cover the 5G-communication frequency band. In this work, a novel microwave power detection system is proposed to measure the power of the 5G-communication frequency band. The detection system is composed of a signal receiving module, a power detection module and a data processing module. Experiments show that the detection frequency band of this system ranges from 1.4 GHz to 5.3 GHz, the dynamic measurement range is 70 dB, the minimum detection power is −68 dBm, and the sensitivity is 22.3 mV/dBm. Compared with other detection systems, the performance of this detection system in the 5G-communication frequency band is significantly improved. Therefore, this microwave power detection system has certain reference significance and application value in the microwave signal detection of 5G communication systems.

Author(s):  
Christopher C. Jobes ◽  
Jacob Carr

In underground coal mines, miners face the hazard of being struck or pinned by a piece of mobile mining machinery. Proximity detection systems have been developed and are used by the industry to protect miners around these machines by detecting the presence of the miners and automatically issuing warnings or disabling machine motion when a miner is in potentially dangerous proximity. These systems were originally developed for continuous mining machines, slow-moving machines that move on bulldozer-style tracks, and are now mandated by the Mine Safety and Health Administration (MSHA) to be used on continuous mining machines. These systems are now being adapted to other underground vehicles, such as shuttle cars, scoops, and battery haulers — vehicles that move on rubber tires at much higher speeds. There are concerns that the detection range of these systems may not provide for an adequate stopping distance on these faster moving machines. To address these concerns, researchers have developed a dynamic modeling system to determine the stopping distance of mobile underground coal equipment. This model can be used in conjunction with worker escapability data and/or information on interaction with other vehicles to provide insight into whether or not proximity detection systems will be adequate for the underground mining workplace. This paper details the background, development, and operation of the resulting application software, focusing on the utility of the graphical user interface to visualize the generated data. The refined data developed by this process can then be utilized by mine operators and proximity detection system manufacturers to more accurately determine the detection range needed to provide effective protection for miners working in an underground mining environment.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2797
Author(s):  
Jing-Jhong Gao ◽  
Ching-Wei Chiu ◽  
Kuo-Hsing Wen ◽  
Cheng-Sheng Huang

This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500–700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


2021 ◽  
Vol 11 ◽  
pp. 184798042098735
Author(s):  
Xiaohong Li ◽  
Wei Shi ◽  
Wenyan Zhang ◽  
Weiyao Chen ◽  
Dan Cao ◽  
...  

Parkinson’s disease (PD) is a nervous disorder, affects physical movement, and leads to difficulty in balancing, walking, and coordination. A novel sensor is mandatory to determine PD and monitor the progress of the treatment. Neurofilament light chain (NfL) has been recognized as a good biomarker for PD and also helps to distinguish between PD and atypical PD syndromes. Immunosensor was generated by current–volt measurement on gap-fingered interdigitated electrode with silicon dioxide surface to determine NfL level. To enhance the detection, anti-NfL antibody was complexed with gold-nanourchin and immobilized on the sensing electrode. The current–volt response was gradually increased at the linear detection range from 100 fM to 1 nM. Limit of detection and sensitivity were 100 fM with the signal-to-noise ratio at n = 3 on a linear curve ( y = 0.081 x + 1.593; R 2 = 0.9983). Limit of quantification falls at 1 pM and high performance of the sensor was demonstrated by discriminating against other neurogenerative disease markers, in addition, it was reproducible even in serum-spiked samples. This method of detection system aids to measure the level of NfL and leads to determine the condition with PD.


Sign in / Sign up

Export Citation Format

Share Document