scholarly journals Hemoculturas: prevalência de microrganismos e perfil de suscetibilidades aos antimicrobianos em uma unidade hospitalar de Aracaju-Sergipe / Blood cultures: prevalence of microorganisms and antimicrobial susceptibility profile in a hospital unit in Aracaju-Sergipe

2021 ◽  
Vol 4 (6) ◽  
pp. 24366-24378
Author(s):  
Maria Clara do Nascimento Gomes ◽  
Larissa Gusmão Guimarães ◽  
Otávio Matheus Torres Apolonio Silva ◽  
Adrielle Almeida De Jesus ◽  
Maria Luiza Coelho De Sousa ◽  
...  
2014 ◽  
Vol 58 (2) ◽  
pp. 142-146 ◽  
Author(s):  
Kozue Kishii ◽  
Ken Kikuchi ◽  
Atsushi Yoshida ◽  
Katsuko Okuzumi ◽  
Yushi Uetera ◽  
...  

2020 ◽  
Vol 75 (11) ◽  
pp. 3218-3229
Author(s):  
Stefano Mancini ◽  
Elias Bodendoerfer ◽  
Natalia Kolensnik-Goldmann ◽  
Sebastian Herren ◽  
Kim Röthlin ◽  
...  

Abstract Background Rapid antimicrobial susceptibility testing (RAST) of bacteria causing bloodstream infections is critical for implementation of appropriate antibiotic regimens. Objectives We have established a procedure to prepare standardized bacterial inocula for Enterobacterales-containing clinical blood cultures and assessed antimicrobial susceptibility testing (AST) data generated with the WASPLabTM automated reading system. Methods A total of 258 blood cultures containing Enterobacterales were examined. Bacteria were enumerated by flow cytometry using the UF-4000 system and adjusted to an inoculum of 106 cfu/mL. Disc diffusion plates were automatically streaked, incubated for 6, 8 and 18 h and imaged using the fully automated WASPLabTM system. Growth inhibition zones were compared with those obtained with inocula prepared from primary subcultures following the EUCAST standard method. Due to time-dependent variations of the inhibition zone diameters, early AST readings were interpreted using time-adjusted tentative breakpoints and areas of technical uncertainty. Results and conclusions Inhibition zones obtained after 18 h incubation using an inoculum of 106 cfu/mL prepared directly from blood cultures were highly concordant with those of the EUCAST standard method based on primary subcultures, with categorical agreement (CA) of 95.8%. After 6 and 8 h incubation, 89.5% and 93.0% of the isolates produced interpretable results, respectively, with CA of >98.5% and very low numbers of clinical categorization errors for both the 6 h and 8 h readings. Overall, with the standardized and automated RAST method, consistent AST data from blood cultures containing Enterobacterales can be generated after 6–8 h of incubation and subsequently confirmed by standard reading of the same plate after 18 h.


2017 ◽  
Vol 11 (4) ◽  
pp. 219-225
Author(s):  
Mylena Karoline Valmorbida ◽  
Danielle Correia dos Santos Carneiro ◽  
Keila Catarina Prior ◽  
Eliete Griebeler ◽  
Marcella Zampoli Troncarelli ◽  
...  

Author(s):  
Mokshanand Fhooblall ◽  
Fikile Nkwanyana ◽  
Koleka P. Mlisana

Background: There are presently many non-culture-based methods commercially available to identify organisms and antimicrobial susceptibility from blood culture bottles. Each platform has its benefits and limitations. However, there is a need for an improved system with minimal hands-on requirements and short run times.Objectives: In this study, the performance characteristics of the FilmArray® BCID Panel kit were evaluated to assess the efficiency of the kit against an existing system used for identification and antimicrobial susceptibility of organisms from blood cultures.Methods: Positive blood cultures that had initially been received from hospitalised patients of a large quaternary referral hospital in Durban, South Africa were processed as per routine protocol at its Medical Microbiology Laboratory. Positive blood cultures were processed on the FilmArray BCID Panel kit in parallel with the routine sample processing. Inferences were then drawn from results obtained.Results: Organism detection by the FilmArray BCID panel was accurate at 92.6% when organisms that were on the repertoire of the kit were considered, compared to the combination methods (reference method used in the study laboratory). Detection of the antimicrobial resistance markers provided by the panel and reference method demonstrated 100% consistency. Blood cultures with a single organism were accurately identified at 93.8% by FilmArray, while blood cultures with more than one organism were identified at 85.7%.Conclusion: The FilmArray BCID Panel kit is valuable for detection of organisms and markers of antibiotic resistance for an extensive range of organisms.


Sign in / Sign up

Export Citation Format

Share Document