scholarly journals The Optimal Power Flow Solution by Optimal Location of STATCOM Device using AHP Method

Optimum power flow is a useful tool for planning and operating the electrical system and maintains the economy and safety of the modern electrical system. Teaching, Learningbased Algorithm is one of the new Metaheuristic algorithms which can influence both teachers and students by expediting the interaction among them in sharing the necessary knowledge. The proposed TLBO is designed here to solve the problem of an optimum power flow with STATCOM FACTS device. The optimal location of STATCOM FACTS device on the weak bus is obtained by Analytical Hierarchy Process (AHP) method. The main objective of this study is to reduce fuel cost of generation, reduce active and reactive power loss, improve voltage deviation and enhance voltage stability index within the given control variable constraints. The proposed TLBO algorithm with STATCOM device is evaluated on the standard IEEE-57 bus system. From the simulation result, it shows that the Teaching Learning-based algorithm gives the optimal solution as compared to the recent algorithm mentioned in the literature with some IEEE-57 bus test system.

The secure operation of power system has become a topmost issue in today's largely complicated interconnected power systems. This chapter presents the implementation of grey wolf optimization (GWO), teaching-learning-based optimization (TLBO), biogeography-based optimization (BBO), krill herd algorithm (KHA), chemical reaction optimization (CRO), and hybrid CRO (HCRO) approaches to find the optimal location of various FACTS devices such as thyristor control series compensator (TCSC), thyristor control phase shifter (TCPS), and static VAR compensator (SVC) to solve optimal power flow (OPF) and optimal reactive power dispatch (ORPD) in power system. In this chapter, a standard IEEE 30-bus test system with multiple TCSC and TCPS and SVC devices are used for different single and multi-objective functions to validate the performance of the proposed methods. The simulation results validate the ability of the HCRO to produce better optimal solutions compared to GWO, TLBO, BBO, KHA, and CRO algorithms.


2018 ◽  
Vol 24 (3) ◽  
pp. 84
Author(s):  
Hassan Abdullah Kubba ◽  
Mounir Thamer Esmieel

Nowadays, the power plant is changing the power industry from a centralized and vertically integrated form into regional, competitive and functionally separate units. This is done with the future aims of increasing efficiency by better management and better employment of existing equipment and lower price of electricity to all types of customers while retaining a reliable system. This research is aimed to solve the optimal power flow (OPF) problem. The OPF is used to minimize the total generations fuel cost function. Optimal power flow may be single objective or multi objective function. In this thesis, an attempt is made to minimize the objective function with keeping the voltages magnitudes of all load buses, real output power of each generator bus and reactive power of each generator bus within their limits. The proposed method in this thesis is the Flexible Continuous Genetic Algorithm or in other words the Flexible Real-Coded Genetic Algorithm (RCGA) using the efficient GA's operators such as Rank Assignment (Weighted) Roulette Wheel Selection, Blending Method Recombination operator and Mutation Operator as well as Multi-Objective Minimization technique (MOM). This method has been tested and checked on the IEEE 30 buses test system and implemented on the 35-bus Super Iraqi National Grid (SING) system (400 KV). The results of OPF problem using IEEE 30 buses typical system has been compared with other researches.     


2012 ◽  
Vol 61 (2) ◽  
pp. 239-250 ◽  
Author(s):  
M. Kumar ◽  
P. Renuga

Application of UPFC for enhancement of voltage profile and minimization of losses using Fast Voltage Stability Index (FVSI)Transmission line loss minimization in a power system is an important research issue and it can be achieved by means of reactive power compensation. The unscheduled increment of load in a power system has driven the system to experience stressed conditions. This phenomenon has also led to voltage profile depreciation below the acceptable secure limit. The significance and use of Flexible AC Transmission System (FACTS) devices and capacitor placement is in order to alleviate the voltage profile decay problem. The optimal value of compensating devices requires proper optimization technique, able to search the optimal solution with less computational burden. This paper presents a technique to provide simultaneous or individual controls of basic system parameter like transmission voltage, impedance and phase angle, thereby controlling the transmitted power using Unified Power Flow Controller (UPFC) based on Bacterial Foraging (BF) algorithm. Voltage stability level of the system is defined on the Fast Voltage Stability Index (FVSI) of the lines. The IEEE 14-bus system is used as the test system to demonstrate the applicability and efficiency of the proposed system. The test result showed that the location of UPFC improves the voltage profile and also minimize the real power loss.


Author(s):  
K. Padma ◽  
Yeshitela Shiferaw Maru

Incremental industrialization and urbanization is the cause of enhanced energy use as it increases the building of new lines and more inductive loads. As a result, the transmission system losses increased, and the magnitudes of voltage profile values deviated from the stated value, resulting in increased cost of active power generation. To mitigate these issues, adequate reactive power compensation in the transmission line and bus systems should be done. Reactive power is regulated by the proper position of the Flexible AC Transmission System (FACTS). Unified Power Flow Controller (UPFC) is a voltage converter system that increases the voltage profile and reduces loss. In this paper, the optimal power flow solution is considered using a FACTS device based on Multi Population Modified Jaya (MPMJ) optimization algorithm. Using the Analytical Hierarchy Process (AHP) system, the optimal position of the UPFC device is determined by considering the most useful objective function provided by priorities and weighting factors. Therefore, on the standard IEEE-57 bus test system, the proposed MPMJ optimization algorithm is implemented with UPFC for optimal fuel cost values of generation, real power loss, voltage deviation and sum of squared voltage stability index. The result obtained by the proposed algorithm is contrasted with the recent literature algorithm


2014 ◽  
Vol 556-562 ◽  
pp. 1643-1646
Author(s):  
Xue Fei Chang ◽  
Xiang Yu Lv ◽  
De Xin Li

In order to improve the calculation efficiency, active power and reactive power are usually optimized separately in optimal power flow considering the decoupling characteristic. However, this would decrease the economy performance of power system. This paper proposed a weighting factor to formulate a multi-objective model, combining the generation cost and system network loss together. The optimization problem is performed using genetic algorithms and quadratic programming respectively. Finally, the feasibility and efficiency of the proposed model are verified with the IEEE 14 Bus test system.


2021 ◽  
Vol 6 (2) ◽  
pp. 111-118
Author(s):  
Nur Azlin Ashiqin Mohd Amin ◽  
Siti Hafawati Jamaluddin ◽  
Nur Syuhada Muhammat Pazil ◽  
Norwaziah Mahmud ◽  
Norhanisa Kimpol

Electrical energy losses are found in any part of the power system. In the power system, it is essential to minimize the real power loss in transmission lines. The voltage deviation at the load buses through controlling the reactive power flow is very important. This ensures the secured operation of power systems regarding voltage stability and the economics of the process due to loss minimization. In this paper, the Modified Artificial Bee Colony (MABC) algorithm is implemented to solve the power system's optimal reactive power flow problem. Generator bus voltages, transformer tap positions, and settings of switched shunt of compensators are used as decision variables to control the reactive power flow. These control variable values are adjusted for loss reduction. MABC algorithm is tested on the standard IEEE-30 bus test system. The results are compared with Firefly algorithm (FA) and Artificial Bee Colony (ABC) algorithm method to prove the effectiveness of the newest algorithm. The power loss results are quite productive, and the algorithm is the most efficient than the other methods such as ABC algorithm and FA algorithm. These results are produced by Matlab 2017b.


Author(s):  
Sana Khalid Abdul Hassan ◽  
Firas Mohammed Tuaimah

<p>Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with overload transmission system problems such as (increase the total losses, raise the rate of power generation, and the transmission line may be exposed to shut down when the load demand increase from the thermal limit of transmission line) and how can solve this problem by choosing the optimal location and parameters of Unified Power Flow Controllers (UPFCs). which was specified based on Genetic Algorithm (GA) optimization method, it was utilized to search for optimum FACT parameters setting and location based to achieve the following objectives: improve voltages profile, reduce power losses, treatment of power flow in overloaded transmission lines and reduce power generation. MATLAB was used for running both the GA program and Newton Raphson method for solving the load flow of the system The proposed approach is examined and tested on IEEE 30-bus system. The practical part has been solved through Power System Simulation for Engineers (PSS\E) software Version 32.0 (The Power System Simulator for Engineering (PSS/E) software created from Siemens PTI to provide a system of computer programs and structured data files designed to handle the basic functions of power system performance simulation work, such as power flow, optimal power flow, fault analysis, dynamic simulations...etc.). The Comparative results between the experimental and practical parts obtained from adopting the UPFC where too close and almost the same under different loading conditions, which are (5%, 10%, 15% and 20%) of the total load. can show that the total active power losses for the system reduce at 69.594% at normal case after add the UPFC device to the system. also the reactive power losses reduce by 75.483% at the same case as well as for the rest of the cases. in the other hand can noted the system will not have any overload lines after add UPFC to the system with suitable parameters.</p>


2021 ◽  
Vol 11 (15) ◽  
pp. 6883
Author(s):  
Muhammad Riaz ◽  
Aamir Hanif ◽  
Shaik Javeed Hussain ◽  
Muhammad Irfan Memon ◽  
Muhammad Umair Ali ◽  
...  

In an effort to reduce greenhouse gas emissions, experts are looking to substitute fossil fuel energy with renewable energy for environmentally sustainable and emission free societies. This paper presents the hybridization of particle swarm optimization (PSO) with grey wolf optimization (GWO), namely a hybrid PSO-GWO algorithm for the solution of optimal power flow (OPF) problems integrated with stochastic solar photovoltaics (SPV) and wind turbines (WT) to enhance global search capabilities towards an optimal solution. A solution approach is used in which SPV and WT output powers are estimated using lognormal and Weibull probability distribution functions respectively, after simulation of 8000 Monte Carlo scenarios. The control variables include the forecast real power generation of SPV and WT, real power of thermal generators except slack-bus, and voltages of all voltage generation buses. The total generation cost of the system is considered the main objective function to be optimized, including the penalty and reserve cost for underestimation and overestimation of SPV and WT, respectively. The proposed solution approach for OPF problems is verified on the modified IEEE 30 bus test system. The performance and robustness of the proposed hybrid PSO-GWO algorithm in solving the OPF problem is assessed by comparing the results with five other metaheuristic optimization algorithms for the same test system, under the same control variables and system constraints. Simulation results confirm that the hybrid PSO-GWO algorithm performs well compared to other algorithms and shows that it can be an efficient choice for the solution of OPF problems.


PLoS ONE ◽  
2021 ◽  
Vol 16 (8) ◽  
pp. e0256050
Author(s):  
Mohammad Zohrul Islam ◽  
Mohammad Lutfi Othman ◽  
Noor Izzri Abdul Wahab ◽  
Veerapandiyan Veerasamy ◽  
Saifur Rahman Opu ◽  
...  

This study presents a nature-inspired, and metaheuristic-based Marine predator algorithm (MPA) for solving the optimal power flow (OPF) problem. The significant insight of MPA is the widespread foraging strategy called the Levy walk and Brownian movements in ocean predators, including the optimal encounter rate policy in biological interaction among predators and prey which make the method to solve the real-world engineering problems of OPF. The OPF problem has been extensively used in power system operation, planning, and management over a long time. In this work, the MPA is analyzed to solve the single-objective OPF problem considering the fuel cost, real and reactive power loss, voltage deviation, and voltage stability enhancement index as objective functions. The proposed method is tested on IEEE 30-bus test system and the obtained results by the proposed method are compared with recent literature studies. The acquired results demonstrate that the proposed method is quite competitive among the nature-inspired optimization techniques reported in the literature.


Author(s):  
Dunya Sh. Wais ◽  
Wafaa S. Majeed

<span lang="EN-US">This paper proposes a gravitational search algorithm (GSA) to allocate the thyristor-controlled series compensator (TCSC) incorporation with the issue of reactive power management. The aim of using TCSC units in this study is to minimize active and reactive power losses. Reserve beyond the thermal border, enhance the voltage profile and increase transmission-lines flow while continuing the whole generation cost of the system a little increase compared with its single goal base case. The optimal power flow (OPF) described is a consideration for finding the best size and location of the TCSCs devices seeing techno-economic subjects for minimizing fuel cost of generation units and the costs of installing TCSCs devices. The GSA algorithm's high ability in solving the proposed multi-objective problem is tested on two 9 and 30 bus test systems. For each test system, four case studies are considered to represent both normal and emergency operating conditions. The proposed GSA method's simulation results show that GSA offers a practical and robust high-quality solution for the problem and improves system performance.</span>