scholarly journals Diagnostics of actuation system by Hadamard product of integrated motor current residuals applied to electro-mechanical actuators

Author(s):  
Sreedhar Babu G ◽  
Sekhar A.S. ◽  
Lingamurthy. A

The paper presents diagnostics methodology that can identify the event of occurrence of fault in the actuator or the linkage system of the flight control actuation system driven by Linear Electromechanical Actuators (LEMA). The standard data analysis like motor current signature analysis (MCSA) is good at identifying the incipient faults within the elements of the actuators in situations where-in the actuators are driving control surfaces. But in back driven cases, where-in LEMA is driven back by control surfaces, the faults outside the LEMAs are difficult to be detected due to higher mechanical advantages of transmission elements like roller screws, gear train and linkage arms scaling down their effects before reaching the motor. One such event occurred in a ground test, wherein the jet vanes were sheared when back driven by excessive gas dynamic forces. Neither the motor current nor the LEMA position feedback data has any clue of the instance of occurrence of such shearing. The case study is discussed in detail and diagnostics solution for such failures is proposed. A new methodology to pin point the event of occurrence is arrived at based on ground static test data of four independent channels. The same is reassured for its applicability using lab experiments on three samples mimicking the failure. The method's applicability is also extended for extracting events in actual flight, by comparing the flight telemetry data with the mimicked lab level (dry runs) data. The methodology uses the analysis of LEMA motor current data to arrive at the vital diagnostic information. The current data of LEMA directly cannot be interpreted due to non-stationary nature arising from variable speed and its pulsating form because of the pulse width modulation (PWM) switching, threshold voltages and closed loop dynamics of the servo. Hence the motor current is integrated using cumulative trapezoidal method. This integrated data is spline curve fitted to arrive at residuals vector. The Hadamard product is used on the residuals vector to amplify the information and suppress the noise. Further, normalizing is done to compare data across tests and samples. With this, necessary diagnostic information was extracted from static test data. The method is extended for extracting diagnostics information from actual flight using comparison analysis of, the test data in actual environment with mimicked lab level dry runs. It is also verified for applicability in faults directly driven by actuators in lab level experiments on three samples.

1978 ◽  
Vol 61 (3) ◽  
pp. 735-745
Author(s):  
Ellen J De Vries ◽  
Frits J Mulder ◽  
Ben Borsje

Abstract The official first action method for determining vitamin D in multivitamin preparations was modified. The method was collaboratively studied by 7 laboratories, using 6 preparations in oil. The preparations consisted of vitamin D at various levels and at various ratios (in w/w) to vitamin A. Three samples contained cholecalciferol and 3 samples contained vitamin D3 from vitamin D3 resin. After outliers were eliminated by the Dixon test, data were analyzed and averages were compared with amounts of vitamin D known to be in each sample. For samples with vitamin D: vitamin A ratios of 1:0.5, 1:5, and 1:10, the mean vitamin D recoveries were 98.8, 94.6, and 90.7%, respectively. The method has been adopted as official final action.


1978 ◽  
Vol 61 (3) ◽  
pp. 731-734
Author(s):  
Ellen J De Vries ◽  
Frits J Mulder ◽  
Ben Borsje

Abstract The official first action method for determining vitamin D in multivitamin preparations was modified. The method was collaboratively studied by 7 laboratories, using 6 preparations in oil. The preparations consisted of vitamin D at various levels and at various ratios (in w/w) to vitamin A. Three samples contained cholecalciferol and 3 samples contained vitamin D3 from vitamin D3 resin. After outliers were eliminated by the Dixon test, data were analyzed and averages were compared with amounts of vitamin D known to be in each sample. For samples with vitamin D: vitamin A ratios of 1:0.5, 1:5, and 1:10, the mean vitamin D recoveries were 98.8, 94.6, and 90.7%, respectively. The method has been adopted as official final action.


2009 ◽  
Vol 413-414 ◽  
pp. 505-511 ◽  
Author(s):  
Abdelhamid Naid ◽  
Feng Shou Gu ◽  
Yi Min Shao ◽  
Salem Al-Arbi ◽  
Andrew Ball

The induction motor is the most common driver in industry and has been previously proposed as a means of inferring the condition of an entire equipment train, predominantly through the measurement and processing of power supply parameters. This has obvious advantages in terms of being non-intrusive or remote, less costly to apply and improved safety. This paper describes the use of the induction motor current to identify and quantify a number of common faults seeded on a two-stage reciprocating compressor. An analysis of the compressor working cycle leads to current signal the components that are sensitive to the common faults seeded to compressor system, and second- and third-order signal processing tools are used to analyse the current signals. It is shown that the developed diagnostic features: the bispectral peak value from the amplitude modulation bispectrum and the kurtosis from the current gives rise to reliable fault classification results. The low feature values can differentiate the belt looseness from other fault cases and valve leakage and inter-cooler leakage can be separated easily using two linear classifiers. This work provides a novel approach to the analysis stator current data for the diagnosis of motor drive faults.


2006 ◽  
Vol 11-12 ◽  
pp. 713-716 ◽  
Author(s):  
Feng Xiang Li ◽  
Wei Min Yang ◽  
Yu Mei Ding

A method for testing an air-spring was advanced in the beginning. Then ANSYS was utilized to simulate the static test. In the simulation, multiple load steps solution was carried out through APDL *DO-LOOP and array parameter method. Scalar parameter PRESSURE was established as inner pressure tracking parameter to update inner pressure. Table parameter PRESSURES was established as inner pressure output parameter to export inner pressure of each load step. Comparison was done between simulation result and test data to prove the feasibility of simulation. Finally, some major parameters such as cord angle and initial inner pressure were taken into account, which had remarkable effect on the air-spring’s performance.


Sign in / Sign up

Export Citation Format

Share Document