Determination and Prediction of Partition Coefficient Values (Kp) for Printing Ink Solvents on Cookie from the Kp of Each Cookie Ingredient

2009 ◽  
Vol 14 (3) ◽  
pp. 246-251 ◽  
Author(s):  
Duek-Jun An
1975 ◽  
Vol 14 (04) ◽  
pp. 301-309
Author(s):  
A. Marczak ◽  
A. Moszczyńska-Kowalska ◽  
H. Kowalski

SummaryThe relative solubility coefficient of 133Xe and the tissue-blood partition coefficient for the aqueous humour vitreous body, conjunctiva and external eye muscles of the rabbit were determined in vitro at 37° C and at various haematocrit values. The partition coefficient for haematocrit 40 was: for the aqueous humour 0,49 ml/ml, for the vitreous body 0,50 ml/ml, for the conjunctiva 0,81 ml/g and for the external eye muscles 0,77 ml/g. It was found that the solubility of 133Xe in rabbit erythrocytes is about 50 per cent higher than that in human red cells. The consequences of this fact for the precision of blood flow measurements by the method of tissue clearance are discussed.


1987 ◽  
Vol 26 (06) ◽  
pp. 253-257
Author(s):  
M. Mäntylä ◽  
J. Perkkiö ◽  
J. Heikkonen

The relative partition coefficients of krypton and xenon, and the regional blood flow in 27 superficial malignant tumour nodules in 22 patients with diagnosed tumours were measured using the 85mKr- and 133Xe-clearance method. In order to minimize the effect of biological variables on the measurements the radionuclides were injected simultaneously into the tumour. The distribution of the radiotracers was assumed to be in equilibrium at the beginning of the experiment. The blood perfusion was calculated by fitting a two-exponential function to the measuring points. The mean value of the perfusion rate calculated from the xenon results was 13 ± 10 ml/(100 g-min) [range 3 to 38 ml/(100 g-min)] and from the krypton results 19 ± 11 ml/(100 g-min) [range 5 to 45 ml/(100 g-min)]. These values were obtained, if the partition coefficients are equal to one. The equations obtained by using compartmental analysis were used for the calculation of the relative partition coefficient of krypton and xenon. The partition coefficient of krypton was found to be slightly smaller than that of xenon, which may be due to its smaller molecular weight.


Author(s):  
Meysam Shirmohammadi ◽  
Zakiyeh Bayat ◽  
Esmat Mohammadinasab

: Quantitative structure activity relationship (QSAR) was used to study the partition coefficient of some quinolones and their derivatives. These molecules are broad-spectrum antibiotic pharmaceutics. First, data were divided into two categories of train and test (validation) sets using random selection method. Second, three approaches including stepwise selection (STS) (forward), genetic algorithm (GA), and simulated annealing (SA) were used to select the descriptors, with the aim of examining the effect feature selection methods. To find the relation between descriptors and partition coefficient, multiple linear regression (MLR), principal component regression (PCR) and partial least squares (PLS) were used. QSAR study showed that the both regression and descriptor selection methods have vital role in the results. Different statistical metrics showed that the MLR-SA approach with (r2=0.96, q2=0.91, pred_r2=0.95) gives the best outcome. The proposed expression by MLR-SA approach can be used in the better design of novel quinolones and their derivatives.


1985 ◽  
Vol 50 (8) ◽  
pp. 1642-1647 ◽  
Author(s):  
Štefan Baláž ◽  
Anton Kuchár ◽  
Ernest Šturdík ◽  
Michal Rosenberg ◽  
Ladislav Štibrányi ◽  
...  

The distribution kinetics of 35 2-furylethylene derivatives in two-phase system 1-octanol-water was investigated. The transport rate parameters in direction water-1-octanol (l1) and backwards (l2) are partition coefficient P = l1/l2 dependent according to equations l1 = logP - log(βP + 1) + const., l2 = -log(βP + 1) + const., const. = -5.600, β = 0.261. Importance of this finding for assesment of distribution of compounds under investigation in biosystems and also the suitability of the presented method for determination of partition coefficients are discussed.


Sign in / Sign up

Export Citation Format

Share Document