scholarly journals Upgrade to Nucleus® 6 in Previous Generation Cochlear™ Sound Processor Recipients

2018 ◽  
Vol 29 (09) ◽  
pp. 802-813 ◽  
Author(s):  
Allison Biever ◽  
Jan Gilden ◽  
Teresa Zwolan ◽  
Megan Mears ◽  
Anne Beiter

AbstractThe Nucleus® 6 sound processor is now compatible with the Nucleus® 22 (CI22M)—Cochlear’s first generation cochlear implant. The Nucleus 6 offers three new signal processing algorithms that purportedly facilitate improved hearing in background noise.These studies were designed to evaluate listening performance and user satisfaction with the Nucleus 6 sound processor.The research design was a prospective, single-participant, repeated measures designA group of 80 participants implanted with various Nucleus internal implant devices (CI22M, CI24M, Freedom® CI24RE, CI422, and CI512) were recruited from a total of six North American sites.Participants had their external sound processor upgraded to the Nucleus 6 sound processor. Final speech perception testing in noise and subjective questionnaires were completed after four or 12 weeks of take-home use with the Nucleus 6.Speech perception testing in noise showed significant improvement and participants reported increased satisfaction with the Nucleus 6.These studies demonstrated the benefit of the new algorithms in the Nucleus 6 over previous generations of sound processors.

2013 ◽  
Vol 24 (10) ◽  
pp. 927-940 ◽  
Author(s):  
Erin C. Schafer ◽  
Denise Romine ◽  
Elizabeth Musgrave ◽  
Sadaf Momin ◽  
Christy Huynh

Background: Previous research has suggested that electrically coupled frequency modulation (FM) systems substantially improved speech-recognition performance in noise in individuals with cochlear implants (CIs). However, there is limited evidence to support the use of electromagnetically coupled (neck loop) FM receivers with contemporary CI sound processors containing telecoils. Purpose: The primary goal of this study was to compare speech-recognition performance in noise and subjective ratings of adolescents and adults using one of three contemporary CI sound processors coupled to electromagnetically and electrically coupled FM receivers from Oticon. Research Design: A repeated-measures design was used to compare speech-recognition performance in noise and subjective ratings without and with the FM systems across three test sessions (Experiment 1) and to compare performance at different FM-gain settings (Experiment 2). Descriptive statistics were used in Experiment 3 to describe output differences measured through a CI sound processor. Study Sample: Experiment 1 included nine adolescents or adults with unilateral or bilateral Advanced Bionics Harmony (n = 3), Cochlear Nucleus 5 (n = 3), and MED-EL OPUS 2 (n = 3) CI sound processors. In Experiment 2, seven of the original nine participants were tested. In Experiment 3, electroacoustic output was measured from a Nucleus 5 sound processor when coupled to the electromagnetically coupled Oticon Arc neck loop and electrically coupled Oticon R2. Data Collection and Analysis: In Experiment 1, participants completed a field trial with each FM receiver and three test sessions that included speech-recognition performance in noise and a subjective rating scale. In Experiment 2, participants were tested in three receiver-gain conditions. Results in both experiments were analyzed using repeated-measures analysis of variance. Experiment 3 involved electroacoustic-test measures to determine the monitor-earphone output of the CI alone and CI coupled to the two FM receivers. Results: The results in Experiment 1 suggested that both FM receivers provided significantly better speech-recognition performance in noise than the CI alone; however, the electromagnetically coupled receiver provided significantly better speech-recognition performance in noise and better ratings in some situations than the electrically coupled receiver when set to the same gain. In Experiment 2, the primary analysis suggested significantly better speech-recognition performance in noise for the neck-loop versus electrically coupled receiver, but a second analysis, using the best performance across gain settings for each device, revealed no significant differences between the two FM receivers. Experiment 3 revealed monitor-earphone output differences in the Nucleus 5 sound processor for the two FM receivers when set to the +8 setting used in Experiment 1 but equal output when the electrically coupled device was set to a +16 gain setting and the electromagnetically coupled device was set to the +8 gain setting. Conclusions: Individuals with contemporary sound processors may show more favorable speech-recognition performance in noise electromagnetically coupled FM systems (i.e., Oticon Arc), which is most likely related to the input processing and signal processing pathway within the CI sound processor for direct input versus telecoil input. Further research is warranted to replicate these findings with a larger sample size and to develop and validate a more objective approach to fitting FM systems to CI sound processors.


2015 ◽  
Vol 26 (06) ◽  
pp. 532-539 ◽  
Author(s):  
Jace Wolfe ◽  
Mila Morais ◽  
Erin Schafer

Background: Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a wireless, remote-microphone, digital, audio-streaming accessory device (heretofore referred to as a remote-microphone accessory) designed to deliver audio signals directly to a CI sound processor. Purpose: The objective of this study was to compare speech recognition in quiet and in noise of recipients while using their CI alone and with a remote-microphone accessory. Research Design: A two-way repeated measures design was used to evaluate performance differences obtained in quiet and in increasing levels of competing noise with the CI sound processor alone and with the sound processor paired to the remote microphone accessory. Study Sample: Sixteen users of Cochlear Nucleus 24 Freedom, CI512, and CI422 implants were included in the study. Data Collection and Analysis: Participants were evaluated in 14 conditions including use of the sound processor alone and with the remote-microphone accessory in quiet and at the following signal levels: 65 dBA speech (at the location of the participant; 85 dBA at the location of the remote microphone) in quiet and competing noise at 50, 55, 60, 65, 70, and 75 dBA noise levels. Speech recognition was evaluated in each of these conditions with one full list of AzBio sentences. Results: Speech recognition in quiet and in all competing noise levels, except the 75 dBA condition, was significantly better with use of the remote-microphone accessory compared with participants’ performance with the CI sound processor alone. As expected, in all technology conditions, performance was significantly poorer as the competing noise level increased. Conclusions: Use of a remote-microphone accessory designed for a CI sound processor provides superior speech recognition in quiet and in noise when compared with performance obtained with the CI sound processor alone.


2010 ◽  
Vol 21 (07) ◽  
pp. 441-451 ◽  
Author(s):  
René H. Gifford ◽  
Lawrence J. Revit

Background: Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise. Most speech perception measures in the clinical setting, however, do not provide a close approximation to real-world listening environments. Purpose: To assess speech perception for adult cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether commercially available preprocessing strategies and/or external accessories yield improved sentence recognition in noise. Research Design: Single-subject, repeated-measures design with two groups of participants: Advanced Bionics and Cochlear Corporation recipients. Study Sample: Thirty-four subjects, ranging in age from 18 to 90 yr (mean 54.5 yr), participated in this prospective study. Fourteen subjects were Advanced Bionics recipients, and 20 subjects were Cochlear Corporation recipients. Intervention: Speech reception thresholds (SRTs) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the subjects' preferred listening programs as well as with the addition of either Beam™ preprocessing (Cochlear Corporation) or the T-Mic® accessory option (Advanced Bionics). Data Collection and Analysis: In Experiment 1, adaptive SRTs with the Hearing in Noise Test sentences were obtained for all 34 subjects. For Cochlear Corporation recipients, SRTs were obtained with their preferred everyday listening program as well as with the addition of Focus preprocessing. For Advanced Bionics recipients, SRTs were obtained with the integrated behind-the-ear (BTE) mic as well as with the T-Mic. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the preprocessing strategy or external accessory in reducing the SRT in noise. In addition, a standard t-test was run to evaluate effectiveness across manufacturer for improving the SRT in noise. In Experiment 2, 16 of the 20 Cochlear Corporation subjects were reassessed obtaining an SRT in noise using the manufacturer-suggested “Everyday,” “Noise,” and “Focus” preprocessing strategies. A repeated-measures ANOVA was employed to assess the effects of preprocessing. Results: The primary findings were (i) both Noise and Focus preprocessing strategies (Cochlear Corporation) significantly improved the SRT in noise as compared to Everyday preprocessing, (ii) the T-Mic accessory option (Advanced Bionics) significantly improved the SRT as compared to the BTE mic, and (iii) Focus preprocessing and the T-Mic resulted in similar degrees of improvement that were not found to be significantly different from one another. Conclusion: Options available in current cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise with both Cochlear Corporation and Advanced Bionics systems. For Cochlear Corporation recipients, Focus preprocessing yields the best speech-recognition performance in a complex listening environment; however, it is recommended that Noise preprocessing be used as the new default for everyday listening environments to avoid the need for switching programs throughout the day. For Advanced Bionics recipients, the T-Mic offers significantly improved performance in noise and is recommended for everyday use in all listening environments.


2013 ◽  
Vol 24 (08) ◽  
pp. 649-659 ◽  
Author(s):  
Kristy Jones Lowery ◽  
Patrick N. Plyler

Background: Directional microphones (D-Mics) and digital noise reduction (DNR) algorithms are used in hearing aids to reduce the negative effects of background noise on performance. Directional microphones attenuate sounds arriving from anywhere other than the front of the listener while DNR attenuates sounds with physical characteristics of noise. Although both noise reduction technologies are currently available in hearing aids, it is unclear if the use of these technologies in isolation or together affects acceptance of noise and/or preference for the end user when used in various types of background noise. Purpose: The purpose of the research was to determine the effects of D-Mic, DNR, or the combination of D-Mic and DNR on acceptance of noise and preference when listening in various types of background noise. Research Design: An experimental study in which subjects were exposed to a repeated measures design was utilized. Study Sample: Thirty adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Data Collection and Analysis: Acceptable noise levels (ANLs) were obtained using no noise reduction technologies, D-Mic only, DNR only, and the combination of the two technologies (Combo) for three different background noises (single-talker speech, speech-shaped noise, and multitalker babble) for each listener. In addition, preference rankings of the noise reduction technologies were obtained within each background noise (1 = best, 3 = worst). Results: ANL values were significantly better for each noise reduction technology than baseline; and benefit increased significantly from DNR to D-Mic to Combo. Listeners with higher (worse) baseline ANLs received more benefit from noise reduction technologies than listeners with lower (better) baseline ANLs. Neither ANL values nor ANL benefit values were significantly affected by background noise type; however, ANL benefit with D-Mic and Combo was similar when speech-like noise was present while ANL benefit was greatest for Combo when speech spectrum noise was present. Listeners preferred the hearing aid settings that resulted in the best ANL value. Conclusion: Noise reduction technologies improved ANL for each noise type, and the amount of improvement was related to the baseline ANL value. Improving an ANL with noise reduction technologies is noticeable to listeners, at least when examined in this laboratory setting, and listeners prefer noise reduction technologies that improved their ability to accept noise.


Author(s):  
Petri Korhonen ◽  
Francis Kuk ◽  
Christopher Slugocki ◽  
Neal Davis-Ruperto

Abstract Background Emotional speech differs from neutral speech in its envelope characteristics. Use of emotional speech materials may be more sensitive for evaluating signal processing algorithms that affect the temporal envelope. Purpose Subjective listener preference was compared between variable speed compression (VSC) and fast acting compression (FAC) amplitude compression algorithms using neutral and emotional speech. Research Design The study used a single-blinded, repeated measures design. Study Sample Twenty hearing-impaired (HI) listeners with a bilaterally symmetrical, mild- to-moderately severe sensorineural hearing loss and 21 listeners with normal hearing (NH) participated. Intervention Speech was processed using FAC and VSC algorithms. Data Collection and Analysis A paired-comparison paradigm assessed subjective preference for FAC versus VSC using emotional and neutral speech materials. The significance of subjective preference for compression algorithm (FAC or VSC) was evaluated using a linear mixed effects model at each combination of stimulus type (emotional or neutral speech) and hearing group (NH or HI). Results HI listeners showed a preference for VSC over FAC when listening to emotional speech. The same listeners showed a nonsignificant, preference for VSC over FAC when listening to neutral speech. NH listeners showed preference for VSC over FAC for both neutral and emotional speech materials. Conclusion These results suggest that the subjective sound quality of emotional speech is more susceptible than neutral speech to changes in the signal introduced by FAC. Clinicians should consider including emotional speech materials when evaluating listener preference for different compression speeds in the clinic.


2011 ◽  
Vol 22 (09) ◽  
pp. 623-632 ◽  
Author(s):  
René H. Gifford ◽  
Amy P. Olund ◽  
Melissa DeJong

Background: Current cochlear implant recipients are achieving increasingly higher levels of speech recognition; however, the presence of background noise continues to significantly degrade speech understanding for even the best performers. Newer generation Nucleus cochlear implant sound processors can be programmed with SmartSound strategies that have been shown to improve speech understanding in noise for adult cochlear implant recipients. The applicability of these strategies for use in children, however, is not fully understood nor widely accepted. Purpose: To assess speech perception for pediatric cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether Nucleus sound processor SmartSound strategies yield improved sentence recognition in noise for children who learn language through the implant. Research Design: Single subject, repeated measures design. Study Sample: Twenty-two experimental subjects with cochlear implants (mean age 11.1 yr) and 25 control subjects with normal hearing (mean age 9.6 yr) participated in this prospective study. Intervention: Speech reception thresholds (SRT) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the experimental subjects’ everyday program incorporating Adaptive Dynamic Range Optimization (ADRO) as well as with the addition of Autosensitivity control (ASC). Data Collection and Analysis: Adaptive SRTs with the Hearing In Noise Test (HINT) sentences were obtained for all 22 experimental subjects, and performance—in percent correct—was assessed in a fixed +6 dB SNR (signal-to-noise ratio) for a six-subject subset. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the SmartSound setting on the SRT in noise. Results: The primary findings mirrored those reported previously with adult cochlear implant recipients in that the addition of ASC to ADRO significantly improved speech recognition in noise for pediatric cochlear implant recipients. The mean degree of improvement in the SRT with the addition of ASC to ADRO was 3.5 dB for a mean SRT of 10.9 dB SNR. Thus, despite the fact that these children have acquired auditory/oral speech and language through the use of their cochlear implant(s) equipped with ADRO, the addition of ASC significantly improved their ability to recognize speech in high levels of diffuse background noise. The mean SRT for the control subjects with normal hearing was 0.0 dB SNR. Given that the mean SRT for the experimental group was 10.9 dB SNR, despite the improvements in performance observed with the addition of ASC, cochlear implants still do not completely overcome the speech perception deficit encountered in noisy environments accompanying the diagnosis of severe-to-profound hearing loss. Conclusion: SmartSound strategies currently available in latest generation Nucleus cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise for pediatric cochlear implant recipients. Despite the reluctance of pediatric audiologists to utilize SmartSound settings for regular use, the results of the current study support the addition of ASC to ADRO for everyday listening environments to improve speech perception in a child's typical everyday program.


2018 ◽  
Vol 29 (09) ◽  
pp. 814-825 ◽  
Author(s):  
Patti M. Johnstone ◽  
Kristen E. T. Mills ◽  
Elizabeth Humphrey ◽  
Kelly R. Yeager ◽  
Emily Jones ◽  
...  

AbstractCochlear implant (CI) users are affected more than their normal hearing (NH) peers by the negative consequences of background noise on speech understanding. Research has shown that adult CI users can improve their speech recognition in challenging listening environments by using dual-microphone beamformers, such as adaptive directional microphones (ADMs) and wireless remote microphones (RMs). The suitability of these microphone technologies for use in children with CIs is not well-understood nor widely accepted.To assess the benefit of ADM or RM technology on speech perception in background noise in children and adolescents with cochlear implants (CIs) with no previous or current use of ADM or RM.Mixed, repeated measures design.Twenty (20) children, ten (10) CI users (mean age 14.3 yrs) who used Advanced Bionics HiRes90K implants with research Naida processors, and ten (10) NH age-matched controls participated in this prospective study.CI users listened with an ear-canal level microphone, T-Mic (TM), an ADM, and a wireless RM at different audio-mixing ratios. Speech understanding with five microphone settings (TM 100%, ADM, RM + TM 50/50, RM + TM 75/25, RM 100%) was evaluated in quiet and in noise.Speech perception ability was measured using children’s spondee words to obtain a speech recognition threshold for 80% accuracy (SRT80%) in 20-talker babble where the listener sat in a sound booth 1 m (3.28′) from the target speech (front) and noise (behind) to test five microphone settings (TM 100%, ADM, RM + TM 50/50, RM + TM 75/25, RM 100%). Group performance-intensity functions were computed for each listening condition to show the effects of microphone configuration with respect to signal-to-noise ratio (SNR). A difference score (CI Group minus NH Group) was computed to show the effect of microphone technology at different SNRs relative to NH. Statistical analysis using a repeated-measures analysis of variance evaluated the effects of the microphone configurations on SRT80% and performance at SNRs. Between-groups analysis of variance was used to compare the CI group with the NH group.The speech recognition was significantly poorer for children with CI than children with NH in quiet and in noise when using the TM alone. Adding the ADM or RM provided a significant improvement in speech recognition for the CI group over use of the TM alone in noise (mean dB advantage ranged from 5.8 for ADM to 16 for RM100). When children with CI used the RM75 or RM100 in background babble, speech recognition was not statistically different from the group with NH.Speech recognition in noise performance improved with the use of ADM and RM100 or RM75 over TM-only for children with CIs. Alhough children with CI remain at a disadvantage as compared with NH children in quiet and more favorable SNRs, microphone technology can enhance performance for some children with CI to match that of NH peers in contexts with negative SNRs.


2014 ◽  
Vol 57 (1) ◽  
pp. 327-337 ◽  
Author(s):  
Mallory Baker ◽  
Emily Buss ◽  
Adam Jacks ◽  
Crystal Taylor ◽  
Lori J. Leibold

Purpose This study evaluated the degree to which children benefit from the acoustic modifications made by talkers when they produce speech in noise. Method A repeated measures design compared the speech perception performance of children (5–11 years) and adults in a 2-talker masker. Target speech was produced in a 2-talker background or in quiet. In Experiment 1, recognition with the 2 target sets was assessed using an adaptive spondee identification procedure. In Experiment 2, the benefit of speech produced in a 2-talker background was assessed using an open-set, monosyllabic word recognition task at a fixed signal-to-noise ratio (SNR). Results Children performed more poorly than adults, regardless of whether the target speech was produced in quiet or in a 2-talker background. A small improvement in the SNR required to identify spondees was observed for both children and adults using speech produced in a 2-talker background (Experiment 1). Similarly, average open-set word recognition scores were 11 percentage points higher for both age groups using speech produced in a 2-talker background compared with quiet (Experiment 2). Conclusion The results indicate that children can use the acoustic modifications of speech produced in a 2-talker background to improve masked speech perception, as previously demonstrated for adults.


Author(s):  
Sharon Miller ◽  
Jace Wolfe ◽  
Mila Duke ◽  
Erin Schafer ◽  
Smita Agrawal ◽  
...  

Abstract Background Cochlear implant (CI) recipients frequently experience difficulty understanding speech over the telephone and rely on hearing assistive technology (HAT) to improve performance. Bilateral inter-processor audio streaming technology using nearfield magnetic induction is an advanced technology incorporated within a hearing aid or CI processor that can deliver telephone audio signals captured at one sound processor to the sound processor at the opposite ear. To date, limited data exist examining the efficacy of this technology in CI users to improve speech understanding on the telephone. Purpose The primary objective of this study was to examine telephone speech recognition outcomes in bilateral CI recipients in a bilateral inter-processor audio streaming condition (DuoPhone) compared with a monaural condition (i.e., telephone listening with one sound processor) in quiet and in background noise. Outcomes in the monaural and bilateral conditions using either a telecoil or T-Mic2 technology were also assessed. The secondary aim was to examine how deactivating microphone input in the contralateral processor in the bilateral wireless streaming conditions, and thereby modifying the signal-to-noise ratio, affected speech recognition in noise. Research Design A repeated-measures design was used to evaluate speech recognition performance in quiet and competing noise with the telephone signal transmitted acoustically or via the telecoil to the ipsilateral sound processor microphone in monaural and bilateral wireless streaming listening conditions. Study Sample Nine bilateral CI users with Advanced Bionics HiRes 90K and/or CII devices were included in the study. Data Collection and Analysis The effects of phone input (monaural [DuoPhone Off] vs. bilateral [DuoPhone on]) and processor input (T-Mic2 vs. telecoil) on word recognition in quiet and noise were assessed using separate repeated-measures analysis of variance. Effect of the contralateral device mic deactivation on speech recognition outcomes for the T-Mic2 DuoPhone conditions was assessed using paired Student's t-tests. Results Telephone speech recognition was significantly better in the bilateral inter-processor streaming conditions relative to the monaural conditions in both quiet and noise. Speech recognition outcomes were similar in quiet and noise when using the T-Mic2 and telecoil in the monaural and bilateral conditions. For the acoustic DuoPhone conditions using the T-Mic2, speech recognition in noise was significantly better when the microphone of the contralateral processor was disabled. Conclusion Inter-processor audio streaming allows for bilateral listening on the telephone and produces better speech recognition in quiet and in noise compared with monaural listening conditions for adult CI recipients.


2020 ◽  
Vol 31 (08) ◽  
pp. 578-589
Author(s):  
Robert T. Dwyer ◽  
Jillian Roberts ◽  
René H. Gifford

Abstract Background Microphone location has been shown to influence speech recognition with a microphone placed at the entrance to the ear canal yielding higher levels of speech recognition than top-of-the-pinna placement. Although this work is currently influencing cochlear implant programming practices, prior studies were completed with previous-generation microphone and sound processor technology. Consequently, the applicability of prior studies to current clinical practice is unclear. Purpose To investigate how microphone location (e.g., at the entrance to the ear canal, at the top of the pinna), speech-source location, and configuration (e.g., omnidirectional, directional) influence speech recognition for adult CI recipients with the latest in sound processor technology. Research Design Single-center prospective study using a within-subjects, repeated-measures design. Study Sample Eleven experienced adult Advanced Bionics cochlear implant recipients (five bilateral, six bimodal) using a Naída CI Q90 sound processor were recruited for this study. Data Collection and Analysis Sentences were presented from a single loudspeaker at 65 dBA for source azimuths of 0°, 90°, or 270° with semidiffuse noise originating from the remaining loudspeakers in the R-SPACE array. Individualized signal-to-noise ratios were determined to obtain 50% correct in the unilateral cochlear implant condition with the signal at 0°. Performance was compared across the following microphone sources: T-Mic 2, integrated processor microphone (formerly behind-the-ear mic), processor microphone + T-Mic 2, and two types of beamforming: monaural, adaptive beamforming (UltraZoom) and binaural beamforming (StereoZoom). Repeated-measures analyses were completed for both speech recognition and microphone output for each microphone location and configuration as well as sound source location. A two-way analysis of variance using mic and azimuth as the independent variables and output for pink noise as the dependent variable was used to characterize the acoustic output characteristics of each microphone source. Results No significant differences in speech recognition across omnidirectional mic location at any source azimuth or listening condition were observed. Secondary findings were (1) omnidirectional microphone configurations afforded significantly higher speech recognition for conditions in which speech was directed to ± 90° (when compared with directional microphone configurations), (2) omnidirectional microphone output was significantly greater when the signal was presented off-axis, and (3) processor microphone output was significantly greater than T-Mic 2 when the sound originated from 0°, which contributed to better aided detection at 2 and 6 kHz with the processor microphone in this group. Conclusions Unlike previous-generation microphones, we found no statistically significant effect of microphone location on speech recognition in noise from any source azimuth. Directional microphones significantly improved speech recognition in the most difficult listening environments.