DEVELOPMENT OF FLUORESCENCE POLARIZATION IMMUNOASSAY OF PHTHALATES: COMPARISON OF DIFFERENT DERIVATIVES IN OBTAINING ANTIBODIES AND TRACERS

2021 ◽  
Vol 1 (19) ◽  
pp. 232-234
Author(s):  
I.A. Shanin ◽  
M.R. Karimova ◽  
L.I. Mukhametova

Reagents for fluorescence polarization immunoassay (FPIA) of phthalates have been obtained: phthalate-protein conjugates, polyclonal antibodies, tracers - antigens labeled with fluorescein derivatives. By the example of dibutyl phthalate (DBP) with the use of a portable detector Sentry-200, the FPIA method was developed, which makes it possible to determine DBP in water samples in concentrations 1 μg / ml in 5 min.

Molecules ◽  
2019 ◽  
Vol 24 (24) ◽  
pp. 4462
Author(s):  
Xing Shen ◽  
Jiahong Chen ◽  
Shuwei Lv ◽  
Xiulan Sun ◽  
Boris B. Dzantiev ◽  
...  

Enrofloxacin (ENR) is a widely used fluoroquinolone (FQ) antibiotic for antibacterial treatment of edible animal. In this study, a rapid and highly specific fluorescence polarization immunoassay (FPIA) was developed for monitoring ENR residues in animal foods. First, ENR was covalently coupled to bovine serum albumin (BSA) to produce specific polyclonal antibodies (pAbs). Three fluorescein-labeled ENR tracers (A, B, and C) with different spacers were synthesized and compared to obtain higher sensitivity. Tracer C with the longest arm showed the best sensitivity among the three tracers. The developed FPIA method showed an IC50 (50% inhibitory concentration) of 21.49 ng·mL−1 with a dynamic working range (IC20–IC80) of 4.30–107.46 ng·mL−1 and a limit of detection (LOD, IC10) of 1.68 ng·mL−1. The cross-reactivity (CR) of several structurally related compounds was less than 2%. The recoveries of spiked pork liver and chicken samples varied from 91.3% to 112.9%, and the average coefficients of variation were less than 3.83% and 5.13%, respectively. The immunoassay took only 8 min excluding sample pretreatment. This indicated that the established method had high sensitivity, specificity, and the advantages of simplicity. Therefore, the proposed FPIA provided a useful screening method for the rapid detection of ENR residues in pork liver and chicken.


2005 ◽  
Vol 38 (6) ◽  
pp. 951-969 ◽  
Author(s):  
S. A. Eremin ◽  
N. R. Murtazina ◽  
D. N. Ermolenko ◽  
A. V. Zherdev ◽  
A. A. Mart'ianov ◽  
...  

2003 ◽  
Vol 378 (3) ◽  
pp. 634-641 ◽  
Author(s):  
Julia N. Yakovleva ◽  
Anna Yu. Lobanova ◽  
Ekaterina A. Shutaleva ◽  
Maria A. Kourkina ◽  
Andrey A. Mart’ianov ◽  
...  

2015 ◽  
Vol 7 (10) ◽  
pp. 4246-4251 ◽  
Author(s):  
Pinong Huang ◽  
Suqing Zhao ◽  
Sergei A. Eremin ◽  
Shengwu Zheng ◽  
Dan Lai ◽  
...  

A homogeneous fluorescence polarization immunoassay (FPIA) was developed to detect bisphenol A in environmental water samples.


1999 ◽  
Vol 22 (5) ◽  
pp. 539-542
Author(s):  
Yuji KUROSAKI ◽  
Tomoya ASADA ◽  
Nanae YASUMOTO ◽  
Toshiaki NAKAMURA ◽  
Mikio MASADA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document