Over-Tip Leakage Loss for a Gutter-Type Turbine Blade Tip

2021 ◽  
Vol 45 (10) ◽  
pp. 549-558
Author(s):  
Seon Woo Bong ◽  
Sang Woo Lee
Author(s):  
Jonas Rejek ◽  
Stefan aus der Wiesche ◽  
Reinhard Willinger

In the open literature, an innovative concept for turbine blade tip leakage loss reduction by means of passive tip injection was recently proposed. The present paper presents experimental results obtained for an unshrouded turbine blade corresponding to a 50 % reaction stage. The experiments were performed in a low-speed linear cascade wind tunnel facility with air as working fluid. The effect of passive tip injection on the resulting loss was investigated by detailed five-hole-probe measurements. Cascades with three different tip gap heights and blades with and without passive injection were considered. Special attention was spent to the actual upstream conditions. The detailed flow field measurements showed that at the blade tip exit the leakage flow merged with the main flow and rolled up to a tip leakage vortex. The linear cascade wind tunnel results indicated a slight reduction of the resulting total pressure loss coefficient due to the passive tip injection. The observed tip leakage loss reduction was well comparable with the predictions of simplified analytical model.


2020 ◽  
Vol 142 (2) ◽  
Author(s):  
Sergen Sakaoglu ◽  
Harika S. Kahveci

Abstract The pressure difference between suction and pressure sides of a turbine blade leads to tip leakage flow, which adversely affects the first-stage high-pressure (HP) turbine blade tip aerodynamics. In modern gas turbines, HP turbine blade tips are exposed to extreme thermal conditions requiring cooling. If the coolant jet directed into the blade tip gap cannot counter the leakage flow, it will simply add up to the pressure losses due to leakage. Therefore, the compromise between the aerodynamic loss and the gain in tip-cooling effectiveness must be optimized. In this paper, the effect of tip-cooling configuration on the turbine blade tip is investigated numerically from both aerodynamics and thermal aspects to determine the optimum configuration. Computations are performed using the tip cross section of GE-E3 HP turbine first-stage blade for squealer and flat tips, where the number, location, and diameter of holes are varied. The study presents a discussion on the overall loss coefficient, total pressure loss across the tip clearance, and variation in heat transfer on the blade tip. Increasing the coolant mass flow rate using more holes or by increasing the hole diameter results in a decrease in the area-averaged Nusselt number on the tip floor. Both aerodynamic and thermal response of squealer tips to the implementation of cooling holes is superior to their flat counterparts. Among the studied configurations, the squealer tip with a larger number of cooling holes located toward the pressure side is highlighted to have the best cooling performance.


Author(s):  
Markus Hamik ◽  
Reinhard Willinger

Depending on the blade aspect ratio, tip-leakage losses can contribute up to one third of the total losses in an axial turbine blade row. In unshrouded turbine blade rows, the radial gaps allow working fluid to pass from the pressure to the suction sides. This tip-leakage flow does not contribute to the work output of the turbine stage. Therefore, any technique which tends to reduce tip-leakage losses has the objective to decrease the flow through the tip gaps. A frequently used method of reducing the tip-leakage flow is the modification of the blade tip geometry by so-called squealers or winglets. Since this method decreases the sensitivity of tip-leakage losses on tip gap width, it is called tip desensitization. This paper presents a new method for tip desensitization: the passive blade tip injection. A low speed cascade wind tunnel is used for experimental investigations. Geometry of the turbine cascade is the up-scale of the tip section of a gas turbine rotor row. Three different gap widths in the range from 0.85% to 2.50% chord length are used. Total pressure, static pressure and flow angles are obtained by traversing a pneumatic five-hole probe about 0.3 axial chord lengths downstream of the turbine cascade. For investigations of the tip injection effect, a single blade of the cascade is modified by an injection channel. Based on experimental results, it is shown that the passive tip injection method decreases tip-leakage losses. At small tip gaps, this reduction can be rather significant. Finally, the positive influence of blade tip injection on tip-leakage losses is described by an analytical model based on the discharge coefficient.


Author(s):  
Sergen Sakaoglu ◽  
Harika S. Kahveci

Abstract The pressure difference between suction and pressure sides of a turbine blade leads to the so-called phenomenon, the tip leakage flow, which most adversely affects the first-stage high-pressure (HP) turbine blade tip aerodynamics. In modern gas turbines, HP turbine blade tips are also exposed to extreme thermal conditions requiring the use of tip cooling. If the coolant jet directed into the blade tip gap cannot counter the leakage flow, it will simply add up to the pressure losses due to this leakage flow. Therefore, it is necessary to handle the design of tip cooling in such a way that the compromise between the aerodynamic loss and the gain in the tip cooling effectiveness is optimized. In this paper, the effect of tip cooling configuration on the turbine blade tip is investigated numerically both from the aerodynamics and thermal aspects in order to determine the optimum tip cooling configuration. The studies are carried out using the tip cross-section of General Electric E3 (Energy Efficient Engine) HP turbine first-stage blade for two different tip geometries, squealer tip and flat tip, where the number, location, and diameter of the cooling holes are varied. The study presents a discussion on the overall loss coefficient, the total pressure loss across the tip clearance, and the variation of heat transfer on the blade tip. The aerodynamic and heat transfer results are compared with the experimental data from literature. It is observed that increasing the coolant mass flow rate by using more holes or by increasing the hole diameter results in a decrease in the area-averaged Nusselt number on the tip floor, as expected. The findings show that both aerodynamic and thermal response of the squealer tips to the implementation of cooling holes is superior to their flat counterparts. Among the studied configurations, the squealer tip with larger number of cooling holes located towards the pressure side is highlighted as the configuration having the best cooling performance.


Author(s):  
Jianhua Wang ◽  
Yalin Liu ◽  
Xiaochun Wang ◽  
Zhineng Du ◽  
Shijie Yang

Experimental and numerical investigations of the tip leakage flow characteristics between turbine blade tip and stator wall (shroud) were conducted by a particle image velocimetry (PIV) system and the commercially available software CFX 11.0. A three-time scaled profile of the GE-E3 blade was used as specimen. Two rows of cylindrical film-cooling holes with 1.5mm diameter were arranged in the blade tip. One row with 5 holes was placed in pressure side just below the groove floor, and the other with 11 holes was equidistantly arranged on the tip along the mid camber line. To exhibit the generation and movement of leakage vortex, and to compare the coolant injection effects from different rows, several typical velocity profiles were captured by the PIV system. The experimental results were used as a data source to validate the turbulence model and numerical program. To better understand the mixing characteristics of the coolant injected from different rows with the leakage flow, the fluid fields of the leakage vortex and coolant flow were simulated, and the leakage mass rates from the blade tip in different coolant injection cases and different gaps were quantitatively estimated by the validated numerical program.


Sign in / Sign up

Export Citation Format

Share Document