scholarly journals Quality by design approach for simultaneous determination of original active pharmaceutical ingredient quinabut and its impurities by using HPLC. Message 1

Pharmacia ◽  
2021 ◽  
Vol 68 (1) ◽  
pp. 79-87
Author(s):  
Оlena Golembiovska ◽  
Oleksii Voskoboinik ◽  
Galina Berest ◽  
Sergiy Kovalenko ◽  
Liliya Logoyda

Aim. The aim of study was to develop and validate a simple, highly robust (quality by design (QbD) approach), precise and accurate method using high performance liquid chromatography for the simultaneous determination of original active pharmaceutical ingredient Quinabut and its impurities. Materials and methods. Experiments were performed on a Shimadzu LC-20 Prominence HPLC separation module, equipped with a quaternary gradient pump, temperature controlled column heater, sampler manager and diode array detector and LC-20 Chemstation for data analysis (Shimadzu Corporation, Japan). Same software was used for data acquisition and processing of results. X-Terra RP18 (4.6×150 mm, 5 μm) analytical chromatographic column provided by Waters Corporation (Milford, MA) was used for all optimization experiments. Mobile phase A: acetonitrile R. Mobile phase B: 0.025 M phosphate buffer solution. Samples were chromatographed in gradient mode. Flow rate of the mobile phase: 0.7 mL/min. Column temperature: 40 °С. Detection: at 233 nm wavelength. Injection volume: 50 μl. Results. Screening of the influence of four chromatographic factors on different chromatographic responses was performed as the initial step of analytical method optimization. A randomized fractional factorial experimental design (24–1) of resolution IV with central point was used. Buffer pH, amount of acetonitrile in mobile phase A, the amount of phosphate buffer solution in mobile phase B and column temperature were selected as factors of interest, and were used to generate the fractional factorial experimental design. Linearity was established in the range of LOQ level to 0.2% having regression coefficients 0.9977. Calibration curve – y = 0.0132 + 0.9902. Since Δt for the content of quinabut is less than max δ, the technique is stable over time. The possibility of contamination of the sample by decomposition products by keeping it under stressful conditions (irradiation of the substance solution with UV light (UV irradiation with mercury lamp light); acid hydrolysis with 0.1 M hydrochloric acid solution; oxidative decomposition) was investigated. As a result of the irradiation with UV light, the impurity peaks for about 8.74 min (impurity C) and 12.68 min (impurity B) are additionally revealed. Their content exceeds the limits of normalization and is 0.6% and 3.7%, respectively. Therefore, the powder of the substance and its solutions should be stored away from direct sunlight. The column temperature and the speed of the mobile phase within ± 10% did not significantly affect the test results. The results were found to be within the assay variability limits during the entire process. Conclusion. 1) The optimization of a new analytical method capable of simultaneous determination of quinabut assay and its impurities drug products was performed with a single fractional factorial experimental design. Only 11 experiments were needed for the optimization, while at least 16 experiments would be needed to cover the same analytical method operational region of the first optimization step with a traditional one factor at time (OFAT) approach. 2) HPLC method was developed and validated for the simultaneous detection and quantitation of quinabut and its impurities. 3) The final analytical method optimized with QbD approach was validated according to ICHQ2R1 guideline. The method proved to be sensitive, selective, precise, linear, accurate and stability-indicating. 4) The method was successfully applied to the analysis of demonstrating acceptable precision and adequate sensitivity for the detection and quantitation of quinabut and its impurities. So it may be reasonable to claim that the method can be extended to the analysis of drug formulations and stability samples as well. This optimization reflects in saving of time and resources since one stability study includes hundreds of samples tested during the product’s shelf life.

2008 ◽  
Vol 27 (1) ◽  
pp. 53 ◽  
Author(s):  
Rumenka Petkovska ◽  
Claus Cornett ◽  
Aneta Dimitrovska

An enantiospecific RP-HPLC method was developed and validated for the simultaneous determination of clopidogrel and four related compounds specified as impurities. Experimental design was applied during the method optimization (Full factorial 23 design) and robustness testing (Central Composite Face Centered design). Laboratory mixtures of clopidogrel and its impurities in a concentration ratio of 1: 5.0×10–4 were used as an investigation matrix. The three independent variables were the acetonitrile content in the mobile phase, pH of the mobile phase, and the column temperature. A Chromatographic Response Function (CRF) was used for estimation of the system response resolution (Rs). Separation was achieved using mobile phase composition of ACN: Buffer solution pH 6.5 (40:60 v/v) at 30 ºC. A CHIRAL-AGP 4.0 mm × 100 mm, 5.0 μm particle size column was used. The total time for chromatographic separation was approximately 10.0 min. The method was validated for its selectivity, linearity, precision, accuracy and robustness.


Author(s):  
Kishorkumar L. Mule

Objective: To develop and validate new, simple and rapid assay method for Prochlorperazine edisylate drug substance by UPLC as per ICH guidelines.Methods: Ultra performance liquid chromatographic method was developed, optimized and validated on Acquity UPLC by using Acquity BDH300 C4 (100 x 2.1 mm) 1.7µ column. 3.85g ammonium acetate in 1000 ml of water add 0.5 ml trifluoroacetic acid and 1 ml triethylamine (Mobile phase A): 0.5 ml trifluoroacetic acid in 1000 ml acetonitrile mobile phase (Mobile phase B) with gradient program. Detector wavelength 254 nm and column temperature 30 °C.Results: Linearity study was carried out for prochlorperazine edisylate, linearity was calculated from 80 % level to 120% with respect to specification level. The correlation coefficient (r) = 0.999 was proved that the method is robust. The resolution between known impurities and Prochlorperazine edisylate found more than 2.5, it was evident from specificity test that Prochlorperazine edisylate peak are well separated from its related impurities, hence the method is specific. Prochlorperazine edisylate sample solution and mobile phase were found to be stable for at least 3 d.Conclusion: A new, simple and rapid method has been developed and validated for assay determination of prochlorperazine edisylate in drug substance by Ultra Performance Liquid Chromatography (UPLC). The analytical method was developed and validated as per ICH guidelines. The developed method can be used for the fast assay determination of prochlorperazine edisylate drug substances in research laboratories and in the pharmaceutical industry. 


2017 ◽  
Vol 15 (1) ◽  
pp. 293-298
Author(s):  
Pakinaz Y. Khashaba ◽  
Hassan Refat H. Ali ◽  
Mohamed M. El-Wekil

AbstractA simple, rapid, cost-effective, and sensitive TLC-spectrodensitometric method for simultaneous determination of esomeprazole and domperidone was developed and tested in human plasma. Ethyl acetate: methanol: benzene: acetonitrile (5: 4: 8: 3, v/v/v/v) mobile phase was used for separation on TLC plates detected at 286 nm. The linearity ranges were 5-1200 and 2-600 ng/ spot for esomeprazole and domperidone, and limits of detection were 1.73 and 0.59 ng/spot. The effects of four variables affecting Rf were evaluated by fractional factorial design. The benzene volume and saturation time had significant effects.


2010 ◽  
Vol 22 (1-3) ◽  
pp. 22-29 ◽  
Author(s):  
Mehran Mohammadian Fazli ◽  
Ali Reza Mesdaghinia ◽  
Kazem Naddafi ◽  
Simin Nasseri ◽  
Masoud Yunesian ◽  
...  

2012 ◽  
Vol 581-582 ◽  
pp. 68-72
Author(s):  
Chu Qin Yu ◽  
Hua Qing Lin ◽  
Yue Han Hou ◽  
Zhong Feng Shi ◽  
Di Shi Lin

In this study, our purpose was to establish a UPLC method for the simultaneous determination of Paeoniflorin and Paeonol in Houyinan Tablet. The separation was performed on Acquity BEH C18 column(2.1mm×100mm,1.7μm), the mobile phase was acetonitrile-water with gradient elution at a flow rate of 0.2 mL•min-1, the detection wavelength was 230nm, the column temperature was 30°Cand the injection volume was 2μL. Paeoniflorin and Paeonol reached effective separation with the other components in this chromatographic conditions. Paeoniflorin and Paeonol were linear within the range of 0.0406~0.4064μg(r=0.9999) and 0.0426~0.4256μg (r=0.9999), respectively. The average recovery was 99.82% and 100.6%. The results of method validation indicated that the method was simple,quick,accurate, specific and less solvent consumption. It can be used for the quality control of Houyinan Tablet.


2018 ◽  
Vol 11 (1) ◽  
Author(s):  
Camila A. Rezende ◽  
Beatriz W. Atta ◽  
Marcia C. Breitkreitz ◽  
Rachael Simister ◽  
Leonardo D. Gomez ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Yu Zhou ◽  
Wu Ling Wei ◽  
Jiang Xing Hua ◽  
Qingsheng Fan

A simple, rapid, and specific HPLC method was established for simultaneous determination of five major lignans (Schizandrol A,Schizandrol B,Schisandrin A,γ-Schisandrin, andSchisandrin C) inSchisandra chinensis. The five lignans can be separated completely on Kromasil C18column (250 nm × 4.6 nm) and then detected at 254 nm using methanol (mobile phase A) and water (mobile phase B) with gradient elution as the mobile phase at 1.0 mL/min flow rate. The column temperature was 30°C. The method was validated in terms of linearity, precision, stability, repeatability, and recovery. Results showed that the method is accurate and reproducible.