Combined Limited Internal Fixation With Circular Frame External Fixation of Intra-Articular Tibial Fractures

Orthopedics ◽  
1999 ◽  
Vol 22 (11) ◽  
pp. 1019-1025
Author(s):  
Steven Raikin ◽  
Mark I Froimson
2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Caroline B. Hing ◽  
Elizabeth Tutton ◽  
Toby O. Smith ◽  
Molly Glaze ◽  
Jamie R. Stokes ◽  
...  

Abstract Background Segmental tibial fractures are fractures in two or more areas of the tibial diaphysis resulting in a separate intercalary segment of the bone. Surgical fixation is recommended for patients with segmental tibial fractures as non-operative treatment outcomes are poor. The most common surgical interventions are intramedullary nailing (IMN) and circular frame external fixation (CFEF), but evidence about which is better is of poor quality. An adequately powered randomised controlled trial (RCT) to determine optimum treatment is required. STIFF-F aimed to assess the feasibility of a multicentre RCT comparing IMN with CFEF for segmental tibial fracture. Methods STIFF-F was a mixed-methods feasibility study comprising a pilot RCT conducted at six UK Major Trauma Centres, qualitative interviews drawing on Phenomenology and an online survey of rehabilitation. The primary outcome was recruitment rate. Patients, 16 years and over, with a segmental tibial fracture (open or closed) deemed suitable for IMN or CFEF were eligible to participate. Randomisation was stratified by site using random permuted blocks of varying sizes. Participant or assessor blinding was not possible. Interviews were undertaken with patients about their experience of injury, treatment, recovery and participation. Staff were interviewed to identify contextual factors affecting trial processes, their experience of recruitment and the treatment pathway. An online survey was developed to understand the rehabilitation context of the treatments. Results Eleven patients were screened and three recruited to the pilot RCT. Nineteen staff and four patients participated in interviews, and 11 physiotherapists responded to the survey. This study found the following: (i) segmental tibial fractures were rarer than anticipated, (ii) the complexity of the injury, study setup times and surgeon treatment preferences impeded recruitment, (iii) recovery from a segmental tibial fracture is challenging, and rehabilitation protocols are inconsistent and (iv) despite the difficulty recruiting, staff valued this research question and strived to find a way forward. Conclusion The proposed multicentre RCT comparing IMN with CFEF is not feasible. This study highlighted the difficulty of recruiting patients to an RCT of a complex rare injury over a short time period. Trial registration The study was registered with the International Standard Randomised Controlled Trials Number Registry: ISRCTN11229660


2014 ◽  
Vol 20 (1) ◽  
pp. 44-49
Author(s):  
Șerban Al. ◽  
Obadă B. ◽  
Turcu R. ◽  
Anderlik St. ◽  
Botnaru V.

ABSTRACT Fractures of the horizontal surface of the distal tibia are known commonly as pylon or plafond fractures, and represent 1-5% of lower extremity fractures, 7-10% of all tibial fractures. The protocol consisted of immediate (within eight to 24 hours) open reduction and internal fixation of the fibula, using a fibular plate or one third tubular plate and application of an external fixator spanning the ankle joint. In the second stage, the treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can preserve soft tissue, simplify operative procedure and decrease wound, obtain rigid internal fixation and guarantee early function exercises of ankle joint. In this study we evaluated 22 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with multifragmentary fractures of the distal tibia. This study evaluates the treatment of complex fractures of distal tibia with locked plate after external fixation. There were 17 males and 5 females of mean age 51,7 years (31-68). The mean follow-up period was 14 weeks. (Ranging from 9-16 weeks). All patients were fully weight bearing at 16 weeks (ranging 9-16 weeks) showing radiological union. There were no cases of failures of fixation, or rotational misalignment. No significant complication was observed in our patients. MIPO is an effective method of treatment for distal tibial fractures, reduce surgical trauma and maintain a more biologically favorable environment for fracture healing, reducing risks of infection and nonunion.


Author(s):  
Siddharth Goel ◽  
Abhay Elhence

Background: Fractures of the distal tibia are among the most difficult fractures to treat. The short distal segment presents difficulty in choosing the appropriate fixation method. The greatest challenge lies in the relatively tight soft tissue around the ankle. As a result, it has been a recent interest in treating these fractures with external fixation and limited internal fixation. The external stable fixation methods used are tubular or ring fixators, with or without immobilising the ankle. This minimally invasive nature of the surgery can avoid catastrophic wound complications like dehiscence, implant exposure and infection.Methods: 18 patients with extra-articular distal tibial fractures (AO Type 43A) were treated with the technique of ankle spanning external fixation. Lag screws or K-wires were supplemented for limited internal fixation when required. Fibula was stabilised in all cases. Intra- articular and Compound fractures were excluded. In addition to union at fracture site, ankle pain and motion was noted in each follow-up.Results: The mean follow-up was 25 months. Of the 18 patients included all but one fractures united with an average healing time of 16 to 18 weeks. Ankle pain and motion was graded according to Mazur modified by Teeny and Wiss clinical scoring system. 15 of them had excellent or good results, 2 had fair results. One patient had poor result. Five pin tract infections occurred. 17 patients had no evidence of osteoarthritis after completing follow up of at least 2 years.Conclusions: Distal tibial fractures are complex injuries, not only regarding the bony component, but also in terms of the management of the soft tissue problem. Ankle Spanning External Fixator with Limited Internal fixation is a relatively simple and cost-effective method for treating these fractures, achieving union and also maintaining ankle function.


2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

BACKGROUND Background: With the development of social economy, severe and complex tibial fractures caused by high-energy injuries such as traffic accidents have gradually increased. At present, the commonly used methods for the treatment of tibial fractures include plate fixation, intramedullary nail fixation, and external fixation. Most of these fractures are open wounds with severe soft tissue injury and wound contamination, and some even have bone defects, which makes the previous internal fixation treatment difficult. OBJECTIVE Objective: This study was aimed to explore Intelligent Computer Information Assisted Taylor Three-dimensional External Fixation for the treatment of tibiofibular fractures. METHODS Methods: 70 patients were collected and divided into Taylor three-dimensional external fixation (TSF) group (28 patients with severe tibial fractures treated with TSF) and the internal fixation group (42 patients with severe complicated tibiofibular fractures treated by internal fixation). After the treatment, the follow-up evaluation of Intelligent Computer Information Assisted Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. RESULTS Results: The results showed that Intelligent Computer Information Assisted Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. CONCLUSIONS Conclusions: Intelligent Computer Information Assisted Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures which is worthy of clinical promotion. CLINICALTRIAL


2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

UNSTRUCTURED The retrospective study of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures provides a theoretical basis for the application of this technology. The paper collected 28 patients with tibiofibular fractures from the Department of Orthopaedics in our hospital from March 2015 to June 2018. After the treatment, the follow-up evaluation of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. The results showed that Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. To this end, the thesis research can be concluded as follows: Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures, it is worthy of clinical promotion.


Sign in / Sign up

Export Citation Format

Share Document