A Study of Structures in ZnO and ZnO:V2O5 Thin Films by In-Situ Synchrotron X-ray Scattering

2007 ◽  
Vol 51 (92) ◽  
pp. 862 ◽  
Author(s):  
S. W. Hwang ◽  
H. K. Kim ◽  
Yoon-Hwae Hwang ◽  
Kwang-Nak Koh
2012 ◽  
Vol 544 ◽  
pp. 34-38 ◽  
Author(s):  
T. Hosokai ◽  
A. Hinderhofer ◽  
A. Vorobiev ◽  
C. Lorch ◽  
T. Watanabe ◽  
...  

2005 ◽  
Vol 38 (8) ◽  
pp. 3395-3405 ◽  
Author(s):  
Byeongdu Lee ◽  
Jinhwan Yoon ◽  
Weontae Oh ◽  
Yongtaek Hwang ◽  
Kyuyoung Heo ◽  
...  

Small ◽  
2021 ◽  
pp. 2103213
Author(s):  
Bryan D. Paulsen ◽  
Alexander Giovannitti ◽  
Ruiheng Wu ◽  
Joseph Strzalka ◽  
Qingteng Zhang ◽  
...  

2017 ◽  
Vol 88 (6) ◽  
pp. 066101 ◽  
Author(s):  
Stephan Pröller ◽  
Daniel Moseguí González ◽  
Chenhuii Zhu ◽  
Eric Schaible ◽  
Cheng Wang ◽  
...  

2009 ◽  
Vol 43 (1) ◽  
pp. 110-121 ◽  
Author(s):  
U-Ser Jeng ◽  
Chiu Hun Su ◽  
Chun-Jen Su ◽  
Kuei-Fen Liao ◽  
Wei-Tsung Chuang ◽  
...  

At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B4C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air–liquid or liquid–liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ∼5 m. The sample stage can accommodate various sample geometries for air–liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1–4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realizedviaa data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustratedviaseveral different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ∼250 nm in a supramolecular complex, (3) SAXS for polymer blends underin situdrawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formedin situat the air–water interface.


2017 ◽  
Vol 27 (46) ◽  
Author(s):  
Jacobus J. van Franeker ◽  
Daniel Hermida-Merino ◽  
Cedric Gommes ◽  
Kirill Arapov ◽  
Jasper J. Michels ◽  
...  

Metals ◽  
2016 ◽  
Vol 6 (6) ◽  
pp. 125 ◽  
Author(s):  
Sara Callori ◽  
Christine Rehm ◽  
Grace Causer ◽  
Mikhail Kostylev ◽  
Frank Klose

Sign in / Sign up

Export Citation Format

Share Document