scholarly journals Non-invasive measurement of cardiovascular stress responses by a photoplethysmography-built-in PC mouse

2009 ◽  
Vol 33 (1) ◽  
pp. 80-84 ◽  
Author(s):  
Yoshimi NAKAZONO ◽  
Hiroaki OZEKI ◽  
Junichi MIZUSAWA
2001 ◽  
Vol 120 (5) ◽  
pp. A266-A266
Author(s):  
R BUTLER ◽  
B ZACHARAKIS ◽  
D MOORE ◽  
K CRAWFORD ◽  
G DAVIDSON ◽  
...  

2008 ◽  
Vol 16 (3) ◽  
pp. 112-115 ◽  
Author(s):  
Stephan Bongard ◽  
Volker Hodapp ◽  
Sonja Rohrmann

Abstract. Our unit investigates the relationship of emotional processes (experience, expression, and coping), their physiological correlates and possible health outcomes. We study domain specific anger expression behavior and associated cardio-vascular loads and found e.g. that particularly an open anger expression at work is associated with greater blood pressure. Furthermore, we demonstrated that women may be predisposed for the development of certain mental disorders because of their higher disgust sensitivity. We also pointed out that the suppression of negative emotions leads to increased physiological stress responses which results in a higher risk for cardiovascular diseases. We could show that relaxation as well as music activity like singing in a choir causes increases in the local immune parameter immunoglobuline A. Finally, we are investigating connections between migrants’ strategy of acculturation and health and found e.g. elevated cardiovascular stress responses in migrants when they where highly adapted to the German culture.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2162
Author(s):  
Mohammad Mamouei ◽  
Subhasri Chatterjee ◽  
Meysam Razban ◽  
Meha Qassem ◽  
Panayiotis A. Kyriacou

Dermal water content is an important biophysical parameter in preserving skin integrity and preventing skin damage. Traditional electrical-based and open-chamber evaporimeters have several well-known limitations. In particular, such devices are costly, sizeable, and only provide arbitrary outputs. They also do not permit continuous and non-invasive monitoring of dermal water content, which can be beneficial for various consumer, clinical, and cosmetic purposes. We report here on the design and development of a digital multi-wavelength optical sensor that performs continuous and non-invasive measurement of dermal water content. In silico investigation on porcine skin was carried out using the Monte Carlo modeling strategy to evaluate the feasibility and characterize the sensor. Subsequently, an in vitro experiment was carried out to evaluate the performance of the sensor and benchmark its accuracy against a high-end, broad band spectrophotometer. Reference measurements were made against gravimetric analysis. The results demonstrate that the developed sensor can deliver accurate, continuous, and non-invasive measurement of skin hydration through measurement of dermal water content. Remarkably, the novel design of the sensor exceeded the performance of the high-end spectrophotometer due to the important denoising effects of temporal averaging. The authors believe, in addition to wellbeing and skin health monitoring, the designed sensor can particularly facilitate disease management in patients presenting diabetes mellitus, hypothyroidism, malnutrition, and atopic dermatitis.


Author(s):  
Konstantinos Markakis ◽  
Nikolaos Pagonas ◽  
Eleni Georgianou ◽  
Panagiota Zgoura ◽  
Benjamin J. Rohn ◽  
...  

2021 ◽  
Vol 21 (9) ◽  
pp. 10703-10710
Author(s):  
Weijuan Chen ◽  
Yi Zhang ◽  
Huicheng Yang ◽  
Yishen Qiu ◽  
Hui Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document