scholarly journals The color stability of silorane- and methacrylate-based resin composites

2012 ◽  
Vol 31 (5) ◽  
pp. 879-884 ◽  
Author(s):  
Aromi KANG ◽  
Sung-Ae SON ◽  
Bock HUR ◽  
Young Hoon KWON ◽  
Jung Hoon RO ◽  
...  
2019 ◽  
Vol 30 (1) ◽  
pp. 52-57 ◽  
Author(s):  
Eduardo Haruki Ozera ◽  
Fernanda Miori Pascon ◽  
Américo Bortolazzo Correr ◽  
Regina Maria Puppin-Rontani ◽  
Aline Rogéria de Castilho ◽  
...  

Abstract This study evaluated gloss and color changes of esthetic restorative materials subjected to different acidic beverages. Specimens of resin composites (Z350XT (Z350), IPS Empress Direct (ED), Charisma Diamond (CD)) were prepared and the initial surface gloss and color (ΔE) were measured (n=10). Then, the specimens were immersed in 4 mL of each of the different beverages (cranberry juice; Coca-Cola; coffee or artificial saliva) during 15 min, 3x/day for 14 days and new gloss and color readings were obtained. Color change was evaluated with the ΔE formula and gloss change values were obtained by the formula: (final gloss - initial gloss). Data was submitted to two-way ANOVA followed by Tukey’s post hoc test (a=0.05). CD showed the lowest color change among resin composites. The highest ΔE values were obtained after immersion in coffee and cranberry juice. Coffee promoted the highest gloss change (worst gloss retention), followed by cranberry juice, Coca-cola and artificial saliva (p<0.05). The type of beverage significantly influenced the gloss of resin composites. Coca-cola reduced gloss of the three resin composites in a similar manner. Coffee affected the ED gloss more than that of Z350 and CD, while cranberry juice affected Z350 more than ED and CD. Saliva had a more pronounced effect on the gloss retention of CD than ED. The beverages used in this study influenced the optical surface properties of the composites studied.


2020 ◽  
Vol 45 (3) ◽  
pp. E105-E113
Author(s):  
M Ferooz ◽  
R Bagheri ◽  
D Jafarpour ◽  
MF Burrow

SUMMARY Background: This study investigated the hardness and color stability of five resin composites subjected to different polishing methods following immersion in distilled water or lactic acid for up to three months. Methods and Materials: Three nanohybrid, Paradigm (3M ESPE), Estelite Sigma Quick (Tokuyama), Ice (SDI), and two microhybrid, Filtek P60 and Filtek Z250, composites were examined. Disc-shaped specimens (10×1.5 mm) were prepared and immersed in distilled water for 24 hours then polished using either silicon carbide paper, the Shofu polishing system or were left unpolished (control). The CIE values and microhardness were determined using a spectrophotometer and digital Vickers hardness tester, respectively (n=10) after one, 45, and 90 days of storage in distilled water or lactic acid. Data were analyzed using analysis of variance, Tukey test, and Pearson correlation coefficient. Results: Ice exhibited the greatest color change, yet Paradigm and Filtek P60 demonstrated the least. Overall, discoloration of tested materials was multifactorial and the effect of storage media depended on the material, polishing method and time interval. The greatest hardness was obtained for Paradigm and the lowest for Estelite. Hardness was found to be significantly higher in lactic acid after 45 days (p=0.014) and even higher after 90 days (p&lt;0.001) compared with distilled water. Conclusions: An acidic environment did not adversely affect color stability or microhardness of the resin composites. There was a significantly mild reverse correlation between hardness and color change in both storage media.


2015 ◽  
Vol 26 (5) ◽  
pp. 507-513 ◽  
Author(s):  
Lourenço de Moraes Rego Roselino ◽  
Michelle Alexandra Chinelatti ◽  
Carla Cecilia Alandia-Román ◽  
Fernanda de Carvalho Panzeri Pires-de-Souza

Abstract: Dentifrice abrasiveness and brushing time may increase color change (∆E) and surface roughness (∆Ra) of resin composites. This study aimed to evaluate the effect of mechanical brushing time of dentifrices with different abrasiveness on ∆E and ∆Ra of nanofilled (Z350, 3M ESPE) and nanohybrid (Tetric N-Ceram, Ivoclar Vivadent) resin composites. Sixteen specimens (12 mm diameter x 2 mm thick) were fabricated using a white Teflon matrix of each resin composite and a ceramic (IPS e.max Ceram, Ivoclar Vivadent), used as control. After initial color readouts on white backgrounds (Spectrophotometer PCB 6807, Byk Gardner), with D65 standard illuminant, and surface roughness (Rugosimeter Surfcorder SE 1700, Kosalab) with cut-off=0.8 mm and speed=0.25 mm/s, specimens were assigned (n=8) according to the abrasiveness of the dentifrices: RDA* 68 (Colgate) and RDA* 180 (Colgate Total Plus Whitening). Specimens were submitted to mechanical brushing (58,400 cycles) and after every 14,600 cycles (1 year of brushing by a healthy individual), new color and surface roughness readouts were taken. Color stability was calculated by CIEDE2000. Data were analyzed by 3-way repeated measures ANOVA and Bonferroni test (p<0.05), and demonstrated that the dentifrice abrasiveness (p=0.02) and brushing time (p<0.0001) affected the ∆E of nanofilled resin composite. There was no difference on surface roughness of materials (p=0.6752) or brushing time (p=0.7997). In conclusion, the longer the brushing time and dentifrice abrasiveness, the greater the color change of the nanofilled resin composite. The surface roughness was not influenced by dentifrice abrasiveness.


2017 ◽  
Vol 2 (1) ◽  
pp. 1-5 ◽  
Author(s):  
Jayaprakash Thumu ◽  
Anirudh Kadiyala ◽  
Indira Priyadarshini Bollu ◽  
Srinidhi Vishnu Ballullaya ◽  
Srihari Devalla

ABSTRACT Aim This study is aimed to evaluate the effect of staining solutions on the color stability of bulk fill and conventional nanohybrid resin composites (RCs) when subjected to various immersion periods. Materials and methods A total of 120 cylindrical Teflon molds (4 × 4 mm) were obtained and divided into four groups of 30 each. Molds of groups I and II were filled with Tetric N Ceram Bulk Fill (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Bulk Fill (3M ESPE, St. Paul, MN, USA). Molds of groups III and IV were filled with Tetric N Ceram (Ivoclar Vivadent) and Filtek Z250 XTE (3M ESPE) incremental fill RC. Photo-activation was performed and specimens were incubated. Spectrophotometer analysis was done according to Commission Internationale d'Eclairage Lab color scale. After taking the baseline measurements, 10 samples from each group were immersed in distilled water (control, subgroup a), tea (subgroup b), and coffee (subgroup c) respectively, for 1, 7, and 30 days. The color values of each specimen were remeasured and color change value (E*ab) was calculated after 1, 7, and 30 days. Data were analyzed by Friedman's test and Mann–Whitney U-test; p < 0.05 is considered to be statistically significant. Results Group III specimens showed perceptible color changes at 30-day immersion period in coffee and tea. In group I specimens, color changes were perceptible at 7- and 30-day immersion periods in coffee and only 30-day immersion period in tea. Groups II and IV specimens showed perceptible color changes after all immersion periods in coffee and after 30 days in tea. Conclusion It can be concluded that Tetric N Ceram has less color change than the other nanohybrid RCs investigated when immersed in coffee and tea after various immersion periods. How to cite this article Thumu J, Kadiyala A, Bollu IP, Ballullaya SV, Devalla S. Effect of Staining Solutions on the Color Stability of Conventional and Bulk Fill Nanohybrid Resin Composites: A Spectrophotometric Analysis. J Oper Dent Endod 2017;2(1):1-5.


2017 ◽  
Vol 8 (3) ◽  
pp. 65
Author(s):  
Farzaneh Shirani ◽  
MohammadR Malekipour ◽  
Zahra Taromi ◽  
Saeedeh Shahnazari

2021 ◽  
Vol 11 (10) ◽  
pp. 1865-1872
Author(s):  
Nawaf Labban

This systematic review aimed to compile information and report the color stability and translucency of polymer-infiltrated ceramic-network (PICN) materials for suitable clinical applications in dentistry. Original peer-reviewed articles in electronic databases including PubMed, MEDLINE, Scopus, and Web of Science were searched to identify relevant papers published between January 2013 and August 2020. The published papers were only in the English language and limited to in vitro studies, and experimental reports were considered. The data from nine studies were considered when reviewing the color stability and translucency of PICN in comparison to other commonly used restorative materials. Among the included studies, color stability assessment was performed in five studies, and the other four studies were involved in the combined assessment of both color stability and translucency. PICN materials are a comparatively newer class of restorative materials and are recommended to overcome the drawbacks of ceramics and resin composites. The outcomes of previous laboratory studies still do not provide convincing results regarding the optical properties of PICN materials. However, with existing sources and evidence, PICN materials exhibit less color stability than ceramics do but better color stability compared to that of resin nanoceramics (RNC) and resin composites. The translucency of PICN materials is low compared to that of ceramics, nanoceramics, and resin composites.


2019 ◽  
Vol 44 (1) ◽  
pp. 54-64 ◽  
Author(s):  
CS Rodrigues ◽  
B Dala Nora ◽  
A Mallmann ◽  
LG May ◽  
LB Jacques

Author(s):  
Victor Hugo Torso ◽  
May Anny Alves Fraga ◽  
Raquel Marianna Lopes ◽  
Ana Cecília Corrêa Aranha ◽  
Lourenço Correr‐Sobrinho ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document