The Remote Real-Time Earthquake Monitoring System of Isolated Structure Based in NI cRIO

2013 ◽  
Vol 333-335 ◽  
pp. 1793-1796
Author(s):  
Jian Qiu Chen

The system monitors seismic responses of isolated structure and non-isolated structure in WenChuan with earthquake, and compared with them. The system of seismic sensors collected seismic signals to the FPGA chip, and FPGA transmits the signal to the real-time controller through the internal bus after filtering. The real-time controller monitors signals and triggers the storage, at the same time the controller will transmit data to the host computer through the Ethernet, and the PC as the local server, which can be accessed real-time by remote computers. A plurality of acquisition station support multiple acquisition station synchronization acquisition using the GPS trigger synchronization.

2011 ◽  
Vol 121-126 ◽  
pp. 2162-2166
Author(s):  
Yan Mei Meng ◽  
Hai Feng Pang ◽  
Ying Ning Hu ◽  
Quan Zhou ◽  
Dao Yang Li ◽  
...  

This paper describes the research and implementation of ground source heat pump unit remote real-time monitoring system, researches in remote real-time monitoring system's overall design, hardware design, software design and implementation of OPC communication. The host computer takes advantage of the human-computer interaction interface of configuration software to achieve the remote real-time monitoring for ground source heat pump unit's running state; the lower computer uses data collector to intensively collect the data which is measured by field measuring instruments, and to achieve remote data transmission based on Ethernet, and then to carry out the communication between the host computer and the lower computer via OPC technology. The results show that the system achieves remote real-time monitoring of ground source heat pump unit, and is stable, easy to operate and provides a reliable basis for the actual energy saving effect's evaluation of ground source heat pump system.


2014 ◽  
Vol 1003 ◽  
pp. 249-253
Author(s):  
Hao Fang ◽  
Ai Hua Li ◽  
Yan Fei Liu

To solve the difficulty of traditional video monitoring system in system upgrade and expansion, an solution of embedded video monitoring system based on DaVinci technology was put forward in this paper. By building the monitoring platform by DM6437 and DSP/BIOS in the solution, TVP5151 was used for receiving video signal in PAL/NTSC formats, and an JPEG Baseline Profile Encoder was integrated for video encoding, and the 10/100M Ethernet transmission function was realized based on NDK. Finally, the system is tested and the result shows that the system can capture and transmit D1 format signal in 25f/s and met the real-time requirement. At the same time, the system is easy to use and expand with a bright application prospect.


2013 ◽  
Vol 6 (4) ◽  
Author(s):  
Omar Ariosto Niño Prieto ◽  
Luis Enrique Colmenares-Guillén ◽  
Edilberto Huerta Niño ◽  
Aldo Enrique Aguila Jurado

2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Xianzhou Lyu ◽  
Weiming Wang

Shaft linings in thick weakly cemented stratum have the disadvantages of large deformation and repeated damage after repair. Considering the typical geologic characteristics and the failure characteristics of shaft linings, we establish a multilayer automatic deformation monitoring system in this paper, and the monitoring system can realize the real-time, continuous, and long-term dynamic monitoring on shaft linings. Based on the concrete strength failure criterion under biaxial compression and the analytical solution for spatially axisymmetric problem of thick-wall cylinders, the damage limit of the shaft lining in Xieqiao coal mine is obtained. Then, we choose three sections as the test area according to the typical damage forms of shaft linings to carry out the monitoring scheme on the auxiliary shaft in Xieqiao coal mine. The monitoring results show that the extreme value of the shaft lining deformation is 2.369 mm. And the shaft lining located in the border between the floor aquifer and the bedrock generates the most severe deformation, which is about 89.4% of the deformation limit. The shaft lining deformation increment fluctuates in certain range, which belongs to elastic deformation. Finally, we inverse the stress state according to the deformation value of the shaft lining, and the obtained additional stress is found to be lower than the ultimate compressive strength. Long-term project practice confirms that the deformation monitoring results can reflect the real stress condition of the shaft lining and that the monitoring system can realize the real-time dynamic evaluation for the status of the shaft lining.


2014 ◽  
Vol 1048 ◽  
pp. 541-544
Author(s):  
Huan Huan Nie ◽  
Zhen Lu Wu ◽  
Guo Yan Yu

In this paper the structure of natural gas compressor monitoring system was designed. All the register data in PLC could be obtained to meet the real-time requirement by an instruction of PPI protocol. The technical framework of system was introduced simply, and the parameter method for measuring was put forward in fault diagnosis of natural gas compressor.


2011 ◽  
Vol 121-126 ◽  
pp. 3750-3754 ◽  
Author(s):  
Chung Chiang Hu ◽  
Shing Han Li ◽  
Tien Wei Tsai

The equipments in computer rooms are complicated in nature. Many factors may influence their normal operations, for example: voltage, temperature, humidity, and the normalcy of systems. It would be prudent to have a monitoring system to prevent from unpredictable problems. Most monitoring systems in the market can only issue alarms in abnormal situations and then analyze the aftermath. They are also expansive and lack the ability for distant instant control. To tackle this problem, after our successful and practical experiments, we utilize GSM text messaging ability (i.e. SMS, short message service) and make distant monitoring possible. The monitoring system is established with a reasonable price that is well below current market. With this system, the manager/administrator can monitor the real-time status of equipments in computer rooms, send control commands through SMS and then get them executed to solve the problems instantly and effectively.


Sign in / Sign up

Export Citation Format

Share Document