Oil Film Temperature Field Simulation of Hydrostatic Center Rack of Heavy-Duty Horizontal Boring Lathe

2011 ◽  
Vol 71-78 ◽  
pp. 1578-1581
Author(s):  
Jun Peng Shao ◽  
Chong Li ◽  
Xiao Qiu Xu ◽  
Xiao Dong Yu ◽  
Bo Wu ◽  
...  

In order to research the temperature distribution law of the interstitial oil film on the hydrostatic center rack, the interstitial oil film on the hydrostatic center rack is taken as the research subject. Firstly, a three-dimensional model of the interstitial oil film is built by UG software. Secondly, the constructed three-dimensional model is meshed by ICEM CFD software. Lastly, the constructed finite element model is simulated using the finite element analysis software ANSYS CFX. The results of the simulation show that the temperature near the oil seal edge is higher than oil chamber and oil-returning slot. If the shaft parts rotate clockwise, the temperature of the right high-temperature zone is higher than the left. The research results provide a theoretical basis for the research on the thermal distortion of the middle pillow.

2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Zhun Xu ◽  
Yikai Li ◽  
Shaoqun Zhang ◽  
Liqing Liao ◽  
Kai Wu ◽  
...  

Abstract Background Clinical studies have found that manipulations have a good clinical effect on sacroiliac joint (SIJ) pain without specific causes. However, the specific mechanisms underlying the effect of manipulations are still unclear. The purpose of this study was to investigate the effects of three common manipulations on the stresses and displacements of the normal SIJ and the strains of the surrounding ligaments. Methods A three-dimensional finite element model of the pelvis-femur was developed. The manipulations of hip and knee flexion (MHKF), oblique pulling (MOP), and lower limb hyperextension (MLLH) were simulated. The stresses and displacements of the SIJ and the strains of the surrounding ligaments were analyzed during the three manipulations. Results MOP produced the highest stress on the left SIJ, at 6.6 MPa, while MHKF produced the lowest stress on the right SIJ, at 1.5 MPa. The displacements of the SIJ were all less than 1 mm during the three manipulations. The three manipulations caused different degrees of ligament strain around the SIJ, and MOP produced the greatest straining of the ligaments. Conclusion The three manipulations all produced small displacements of the SIJ and different degrees of ligament strains, which might be the mechanism through which they relieve SIJ pain. MOP produced the largest displacement and the greatest ligament strains.


2011 ◽  
Vol 368-373 ◽  
pp. 3052-3056
Author(s):  
Wei Jun Yang ◽  
Yong Da Yang

New full hall scaffolds with pulley-clip style formwork support system is adopted in the concert hall of Changsha. This paper presents the concept of the complete equivalent initial imperfection according to the characteristics of too many influential factors on the high formwork supporting frame,then makes the complete equivalent initial imperfectione equivalent to assumed equivalent horizontal load in order to ensure the safety of the frame. At the same time, it gets a three-dimensional model by the general finite element software ANSYS 10.0. Based on the results of experiment and finite element analysis, it gets the recommended value of assumed equivalent horizontal load. The study on the high formwork supporting frame with pulley-clip style provides some reference for other similar projects.


2019 ◽  
Vol 1372 ◽  
pp. 012014 ◽  
Author(s):  
Aishah Umairah Abd Aziz ◽  
Hong Seng Gan ◽  
Ahmad Kafrawi Nasution ◽  
Mohammed Rafiq Abdul Kadir ◽  
Muhammad Hanif Ramlee

2013 ◽  
Vol 284-287 ◽  
pp. 996-1000 ◽  
Author(s):  
Jong Boon Ooi ◽  
Xin Wang ◽  
Ying Pio Lim ◽  
Ching Seong Tan ◽  
Jee Hou Ho ◽  
...  

Portal axle unit is a gearbox unit installed on every end axles of the vehicle. It is installed to the vehicle to give higher ground clearance to enable vehicle to go over large obstacle when driving in off-road conditions. Shafts must be exceptionally tough and lightweight to improve the overall performance of the portal axle unit. In this paper, the shaft is analyzed in three-dimensional model and the stress of the shaft model is analyzed using finite element analysis (FEA). The FEA result is compared with experimental results.


2014 ◽  
Vol 960-961 ◽  
pp. 1420-1423
Author(s):  
Zhi Dong Huang ◽  
Guo Fei Li ◽  
Juan Cong ◽  
Yun Wang ◽  
Wei Na Yu ◽  
...  

Based on Solidworks software, the three-dimensional model of two wheels scooter is set up. The finite element model of two wheels scooter is generated. Modal analysis of driving system and telescopic mechanism of bar on two wheels scooter is investigated. The first five orders natural frequency and major modes of driving system and telescopic mechanism of bar are clarified. The method and the result can be used as a reference of dynamic design and lay foundation for calculation and analysis of dynamic response for the two wheels scooter.


2015 ◽  
Vol 713-715 ◽  
pp. 95-98
Author(s):  
Ai Hua Li ◽  
Hong Yu Liu

Cold shearing machine is the machine equipment often used in metallurgical industry to shear head, tail and fixed length of rolled piece. The shearing movement of cold shearing machine can be realized by crankshaft driving link rod with relative up-and-down motion. Load on crankshaft is comparatively big. In this paper, cold shearing machine crankshaft was taken as an example. The three dimensional model of relative cold shearing machine crankshaft was constructed by SolidWorks software. Strength finite element analyses on relative model were made by static analysis module attached to SolidWorks software under maximum load working conditions. The overall displacement distribution pictures and overall Von Mises stress distribution pictures of cold shearing machine crankshaft under relative load working conditions were obtained. This research provides important reference base for the design and reform of cold shearing machine crankshaft.


2020 ◽  
Author(s):  
Zhun Xu ◽  
Yikai Li ◽  
Shaoqun Zhang ◽  
Liqing Liao ◽  
Kai Wu ◽  
...  

Abstract BackgroundClinical studies have found that manipulations have a good clinical effect on sacroiliac joint (SIJ) pain without specific causes. However, the specific mechanisms underlying the effect of manipulations are still unclear. The purpose of this study was to investigate the effects of three common manipulations on the stresses and displacements of the SIJ and the strains of the surrounding ligaments.MethodsA three-dimensional finite element model of the pelvis-femur was developed. The manipulations of hip and knee flexion (MHKF), oblique pulling (MOP), and lower limb hyperextension (MLLH) were simulated. The stresses and displacements of the SIJ and the strains of the surrounding ligaments were analyzed during the three manipulations.ResultsMOP produced the highest stress on the left SIJ, at 6.6 MPa, while MHKF produced the lowest stress on the right SIJ, at 1.5 MPa. The displacements of the SIJ were all less than 1 mm during the three manipulations. The three manipulations caused different degrees of ligament strain around the SIJ, and MOP produced the greatest straining of the ligaments.ConclusionThe three manipulations all produced small displacements of the SIJ and different degrees of ligament strains, which might be the mechanism through which they relieve SIJ pain. MOP may be the most effective of these manual therapies.


Author(s):  
Mauro Mazzei ◽  
Davide Quaroni

In this paper we describe the potentialities of a tool for the visualization of experimental results directly on a three-dimensional model. The case study concerns the visualization of the results of a dynamic finite element analysis (FEA/FEM) applied to the calculation of seismic risk on works belonging to the Italian infrastructural heritage, specifically bridges, viaducts and overpasses. The project is based on finite element analysis performed on an exemplary set of 8 structures located on the Italian territory, performed by means of the open-source software framework OpenSees, according to the guidelines indicated in the Technical Standards for Construction NTC08. The application created for this project is classifiable as a webGIS, since all data are georeferenced and visualized on a map through an application executed through a browser. The graphical interface displays the interested works on the map of the Italian territory and allows to select them by mouse click. Following the selection, a 3D rendering of the model of the work and the surrounding terrain is shown, in which the results of the analysis are represented using color gradients directly on the three-dimensional model. The necessary tools are present for the selection of the type of result and for the animation in real time of the response of the work to the seismic action. The 3D representation is freely navigable by the user thanks to intuitive tools of panning, rotation and zoom through mouse and keyboard. The application takes advantage of HTML5, CSS and Javascript to show graphical features such as Cartesian diagrams of accelerograms used in modal analysis.


2020 ◽  
Author(s):  
Zhun Xu ◽  
Yikai Li ◽  
Shaoqun Zhang ◽  
Liqing Liao ◽  
Kai Wu ◽  
...  

Abstract Background: Clinical studies have found that manipulations have a good clinical effect on sacroiliac joint (SIJ) pain without specific causes. However, the specific mechanisms of manipulations are still unclear. The purpose of this study was to investigate the effects of three common manipulations on the pressures and displacements of SIJ, and the strains of the surrounding ligaments. Methods: A three-dimensional finite element model of the pelvis-femur was developed. The manipulation of hip and knee flexion (MHKF), the manipulation of oblique pulling (MOP), and the manipulation of lower limb hyperextension (MLLH) were simulated. The pressures and displacements of SIJs, and the strains of the surrounding ligaments were analyzed under the three manipulations. Results: The MOP produced the greatest pressure on the left SIJ, at 6.6 MPa, while the MHKF could produce the lowest pressure on the right SIJ, at 1.5 MPa. The displacements of SIJs were all less than 1mm in the three manipulations. The three manipulations could cause different degrees of the strains of ligaments around the SIJs, and the MOP could produce the largest strain of ligaments. Conclusion: The three manipulations all produced small displacements of SIJs, while they caused different degrees of ligament strains, which might be the reason for relieving the SIJ pain. The MOP may be a more effective manual therapy. Key words: Manipulation, Sacroiliac joint, Displacement, Ligament strain, Finite element analysis.


2019 ◽  
Vol 8 (8) ◽  
pp. 1103 ◽  
Author(s):  
García-Braz ◽  
Prados-Privado ◽  
Zanatta ◽  
Calvo-Guirado ◽  
Prados-Frutos ◽  
...  

Background: The goal of this study was to analyze the stress distribution on two types of extra-short dental implants with 5 mm of length: An internal hexagon (IH) and morse taper connection (MT). Methods: The three-dimensional model was composed of trabecular and cortical bone, a crown, an extra-short dental implant and their components. An axial load of 150 N was applied and another inclined 30° with the same magnitude. Results: Stress concentrations on the IH implant are observed in the region of the first threads for the screw. However, in the MT implant the highest stress occurs at the edges of the upper implant platform. Conclusions: In view of the results obtained in this study the two types of prosthetic fittings present a good stress distribution. The Morse taper connections presented better behavior than the internal in both loading configurations.


Sign in / Sign up

Export Citation Format

Share Document