Detection of the Antibiotic TMP in the Water with HPLC-DAD

2015 ◽  
Vol 727-728 ◽  
pp. 790-793 ◽  
Author(s):  
Xiao Na Ji ◽  
Dong Mei Wang ◽  
Zhi Min Ren ◽  
Hua Yang ◽  
Yan Bo Xiao ◽  
...  

Thispaper studies the method of detecting antibiotic trimethoprim (TMP) in theenvironment water, sewage and tap water with high performance liquidchromatography –diode array detector (HPLC-DAD). The chromatographic conditionis confirmed that: the stationary phase is ODS, the mobile phase is acetonitrileand methanoic acid aqueous solution of 0.1%(12:88), the flow rate is 1.5min·L-1; theinjection volume is 5μL,the chromatographic column temperature is 25°C,DAD detection wavelength is 272nm. The experiment result shows that, the linearlydependent coefficient of external standard curve is 0.996, the detection limitis 0.017 mg·L-1, adding standard recovery ranges from 92.6-140.6 %.

Marine Drugs ◽  
2021 ◽  
Vol 19 (6) ◽  
pp. 321
Author(s):  
Maria Orfanoudaki ◽  
Anja Hartmann ◽  
Julia Mayr ◽  
Félix L. Figueroa ◽  
Julia Vega ◽  
...  

This study presents the validation of a high-performance liquid chromatography diode array detector (HPLC-DAD) method for the determination of different mycosporine-like amino acids (MAAs) in the red alga Bostrychia scorpioides. The investigated MAAs, named bostrychines, have only been found in this specific species so far. The developed HPLC-DAD method was successfully applied for the quantification of the major MAAs in Bostrychia scorpioides extracts, collected from four different countries in Europe showing only minor differences between the investigated samples. In the past, several Bostrychia spp. have been reported to include cryptic species, and in some cases such as B. calliptera, B. simpliciuscula, and B. moritziana, the polyphyly was supported by differences in their MAA composition. The uniformity in the MAA composition of the investigated B. scorpioides samples is in agreement with the reported monophyly of this Bostrychia sp.


2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
Thiyagarajan Sathishkumar ◽  
Ramakrishnan Baskar ◽  
Mohan Aravind ◽  
Suryanarayanan Tilak ◽  
Sri Deepthi ◽  
...  

Flavonoids are exploited as antioxidants, antimicrobial, antithrombogenic, antiviral, and antihypercholesterolemic agents. Normally, conventional extraction techniques like soxhlet or shake flask methods provide low yield of flavonoids with structural loss, and thereby, these techniques may be considered as inefficient. In this regard, an attempt was made to optimize the flavonoid extraction using orthogonal design of experiment and subsequent structural elucidation by high-performance liquid chromatography-diode array detector-electron spray ionization/mass spectrometry (HPLC-DAD-ESI/MS) techniques. The shake flask method of flavonoid extraction was observed to provide a yield of 1.2±0.13 (mg/g tissue). With the two different solvents, namely, ethanol and ethyl acetate, tried for the extraction optimization of flavonoid, ethanol (80.1 mg/g tissue) has been proved better than ethyl acetate (20.5 mg/g tissue). The optimal conditions of the extraction of flavonoid were found to be 85°C, 3 hours with a material ratio of 1 : 20, 75% ethanol, and 1 cycle of extraction. About seven different phenolics like robinin, quercetin, rutin, sinapoyl-hexoside, dicaffeic acid, and two unknown compounds were identified for the first time in the flowers of T. heyneana. The study has also concluded that L16 orthogonal design of experiment is an effective method for the extraction of flavonoid than the shake flask method.


2009 ◽  
Vol 92 (2) ◽  
pp. 680-688 ◽  
Author(s):  
Pei Chen ◽  
Renata Atkinson ◽  
Wayne R Wolf

Abstract The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS) for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 m, 250 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100 A (0.1 formic acid in water), a linear gradient to 50 A and 50 B (0.1 formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLD/MS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.


Sign in / Sign up

Export Citation Format

Share Document