Monitoring and Treatment during the Water Leakage Process of a Deep Subway Station Pit

2011 ◽  
Vol 94-96 ◽  
pp. 1951-1956
Author(s):  
Cong Shi Wu ◽  
Gong Liu ◽  
Wei Da Shen

A remedy scheme of water leakage in the deep foundation pit of a subway station is introduced. The deformation and axial forces of the supporting structure as well as the underground water level were monitored during the leaking prevention process. At the same time, a plane model was developed to simulate the construction process of foundation pit by FEM. Then, the fundamental reason for the leaking of the foundation pit was analyzed by numerical results and in situ measured data. Furthermore, importance of the strength of the supporting structure to the excavation of the foundation pit was also detailed demonstrated. Finally, the remedy measures were put forward to prevent the water leakage, which were proved to be effective and feasible in practice.

2014 ◽  
Vol 580-583 ◽  
pp. 787-790
Author(s):  
Hai Xia Sun ◽  
Ke Zhang ◽  
Si Li Chen

This article mainly expounds the importance of in-situ monitoring on the construction process of deep foundation pit. Taking the deep foundation pit of some Shenyang metro station for example, the deformation features of the supporting structure and the internal and external of foundation pit is analyzed, according to the monitoring data of the fender pile displacement during the excavation of deep foundation pit. The conclusion is obtained that the timely and accurate in-situ monitoring information is necessary to guaranteeing construction safety. We should pay more attention to the excavation speed and exert the interior support timely during the excavation of foundation pit to avoid large deformation and danger. The analytical results of monitoring data shows that the whole stage of foundation pit excavation is stable and the fender pile with internal supports can guarantee the stability of foundation pit.


2011 ◽  
Vol 90-93 ◽  
pp. 485-489
Author(s):  
Li Guo ◽  
Peng Li He ◽  
Guang Jun Zhang

The enclosure pile is extensively used as retaining structure in the foundation pit excavation. And it is always combined with other reinforcement measures. So it is unreasonable to a certain degree that the enclosure pile is analyzed as cantilever structure. Taken the deep foundation pit of a subway station in Hefei for instance, the effect of other reinforcement measures on restrained conditions of enclosure piles in the paper was taken into account. And the behavior of enclosure pile under various restrained conditions was analyzed. Based on that, some helpful suggestions for practical retaining structure of foundation pit were put forward.


2011 ◽  
Vol 261-263 ◽  
pp. 1809-1813
Author(s):  
Jin Biao Chen ◽  
Qiang Hu ◽  
Yuan Wu Zhou

The excavation of deep foundation pit is very complex in the field of geotechnical engineering, how to control the deformation of deep foundation pit and protect the environment is of great significance. This paper analyzed the deformation mechanism of pile-anchor joint supporting structure in detail, established a model for deformation controlling based on the reliability theory, and then analyzed the sensitivities of prestressed, pile stiffness, spacing and soil properties to foundation deformation. Combined with an engineering example, this paper verifies the stability and effectiveness of the model for deformation controlling. This study will provide some reference to similar projects.


2011 ◽  
Vol 243-249 ◽  
pp. 2338-2344
Author(s):  
Qing Yuan Li ◽  
Yang Wang

Taking deep excavation engineering in North Region of Senlin Park Station of Beijing Olympic Subway branch as engineering background, deformation law of enclosure structure of deep excavation are studied by the in-situ monitoring means .It shows that the maximum horizontal displacement of retaining pile is closely related with excavation depth and time. When the deep foundation pit is excavated to a certain depth, and steel brace hasn’t been erected, horizontal displacement of the pile tops is maximum. The location of the maximum horizontal displacement shifts down with foundation pit excavation and steel brace erection. With steel brace application, steel axis force decrease, so steel brace can effectively control horizontal displacements of retaining pile and internal force of steel in the pile. In addition, temperature has a certain effect to axis force of steel brace.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Zhouqiang Li

Taking a super large deep foundation pit project as an example, the horizontal displacement of crown beam and driveway, surface settlement, axial force of anchor cable, and underground water level in the construction process of the foundation pit are dynamically monitored and analyzed. The excavation deformation rule of the deep foundation pit and the influence of excavation on surrounding buildings are analyzed. The results show that, with the excavation of the foundation pit, the crown beam and driveway of the foundation pit incline towards the direction of the pit and eventually tend to be stable. The variation of axial force of the prestressed anchor cable in the first layer of the foundation pit is basically consistent with the variation of horizontal displacement time history. The variation trend of the groundwater level at each side of the foundation pit is different but tends to be stable in a short time. In the whole monitoring period, the cumulative settlement value of each area of the foundation pit is within the controllable range, but the surface settlement of the north side of the foundation pit and a surrounding building has not reached stability, so it is suggested to extend the monitoring time of settlement in the relevant area.