All-Solid-State pH Sensor Based on Conducting Polymer

2010 ◽  
Vol 93-94 ◽  
pp. 591-594 ◽  
Author(s):  
W. Natedungta ◽  
W. Prissanaroon-Ouajai

A solid-state (free of internal electrolyte solution) reference electrode based on metallic silver is simply fabricated via a simple electrodeposition from AgNO3. Potentiometry is carried out to study the performance of the solid-state reference electrode in comparison with the commercial Ag/AgCl reference electrode. In addition, the proposed solid-state reference electrode has been integrated with the PPy-modified pH electrode to form an all-solid-state pH sensor, showing the capability of pH measurement. Absence of the internal solution leads to the pH sensor that is convenient to use and maintenance. In addition, the proposed pH sensor is possibly applied to biochemical and medical processes as well as flow infection analysis.

The Analyst ◽  
2022 ◽  
Author(s):  
Mustafa Nigde ◽  
İsmail Ağır ◽  
Rıdvan Yıldırım ◽  
İbrahim Işıldak

Several fundamentally similar, miniaturized solid-state reference electrode designs, their fabrication and comparison was described in this article. All electrodes were based on Ag/AgCl as their reference element. The best electrode...


2017 ◽  
Vol 251 ◽  
pp. 509-523 ◽  
Author(s):  
Karthick Subbiah ◽  
Lee Han-Seung ◽  
Lee Yun Su ◽  
Singh Jitendra Kumar ◽  
Kwon Seung-Jun ◽  
...  

2010 ◽  
Vol 163-167 ◽  
pp. 2945-2948
Author(s):  
Li Juan Kong ◽  
Tong Zhang ◽  
Guang Pin Song

Corrosion of steel structures has been found to be a problem Corrosion can be managed but not eliminated, so detecting corrosion will remain an issue no matter how effective corrosion prevention programs become. Electrochemical reaction is the basically process of steel corrosion in civil engineering, so electrochemical method is the best way to monitor corrosion grade. Liquid state reference is often used in lab to study steel corrosion by triple electrode system, but it is very difficultly used in steel bar corrosion monitoring in civil engineering. Firstly, liquid reference’s life is, generally speaking, very short. The steel corrosion is a very slow process, corrosion monitoring should be tens of years, so the liquid reference’s life is not long enough for corrosion monitoring; Secondly, the reference electrode’s strength have to be very high. Obviously, liquid electrode reference can not meet the requirement. In this paper, a novel all solid state reference electrode (ASSRE) has been developed. There are three layers in the electrode. Four kinds of components have been included in first and second layer. Additional AgCl powder has been used to inhibit AgCl decrease which is on the surface of Ag wire by complexing effect. There is only one kind of component in third layer. There are four steps to prepare the reference electrode: electrolyze, pre-mixed components, modelling and sintering. Finally, the potential of ASSR has been measured by SCE.


2019 ◽  
Vol 166 (8) ◽  
pp. B598-B603 ◽  
Author(s):  
Sagir Alva ◽  
Dego Ardiyansyah ◽  
Deni Shidqi Khaerudini ◽  
Robi Suherman

2012 ◽  
Vol 80 ◽  
pp. 418-425 ◽  
Author(s):  
Stéphanie Lorant ◽  
Claude Bohnke ◽  
Michaël Roffat ◽  
Odile Bohnke

2015 ◽  
Vol 4 (1) ◽  
pp. 53-61 ◽  
Author(s):  
J. C. B. Fernandes ◽  
E. V. Heinke

Abstract. This paper presents an alternative strategy for manufacturing solid-state reference electrodes based on particles of graphite/silver/silver chloride synthesized by electroless deposition of metallic silver and silver chloride on graphite powder. Two kinds of reference electrodes were manufactured by mixing these particles with epoxy resin and hardener: quasi-reference and all-solid-state containing salts of alkaline or alkaline earth metals. All-solid-state reference electrodes can be sterilized with high-pressure saturated steam at 394.15 K (121 °C) using an autoclave. These electrodes presented a stable potential between pH 2 and 11. The electrode surface was characterized by scanning electron microscopy and showed the presence of silver and salt particles. The size of the silver particles was less than 2.5 μm. We successfully applied the all-solid state reference electrodes in potentiometric cells to measure pH and potassium ions in complex matrix by direct potentiometry and L-ascorbic acid by potentiometric titration.


Author(s):  
S. Alva ◽  
L. Y. Heng ◽  
M. Ahmad

<p class="TRANSAffiliation"><span>This research focus on transforming the traditional design of reference electrode into all-solid-state reference electrode front-end using Ag/AgCl screen- printed electrodes. By replacing the internal reference solution of a traditional reference electrode by a solid photocurable membrane, an all-solid-state reference electrode can be achieved. The solid-state screen-printed reference electrode was designed using a photocurable acrylic film containing immobilized sodium tetrakis [3,5-bis(trifluoromethyl)phenyl] borate (NaTFPB) and trimethylocthylammonium chloride (TOMA-Cl). An optimum ratio of NaTFPB:TOMA-Cl = 1:1 produced a stable reference electrode. In the anions interference studies, all anions i.e. NO<sub>3</sub><sup>-</sup>, Cl<sup>-</sup>, Br<sup>-</sup> and SO<sub>4</sub><sup>2-</sup> does not give effect to the SPRE except perchlorate anions. The all-solid-state reference electrodes was applied to the detection of potassium ions  and ammonium ions. Validation of the all-screen-printed reference electrode was performed with reference electrode standard gel type. The validation results showed that all-solid-state screen-printed reference electrode demonstrated performance that was comparable to standard reference electrode. </span></p>


Sign in / Sign up

Export Citation Format

Share Document