Experimental Study of Selected Properties of Heavyweight Concrete Based on Analysis of Chemical Composition and Radioactive Elements of its Components

2021 ◽  
Vol 321 ◽  
pp. 113-118
Author(s):  
Janette Dragomirová ◽  
Martin T. Palou ◽  
Katalin Gméling ◽  
Veronika Szilágyi ◽  
Ildikó Harsányi ◽  
...  

Heavyweight concrete is mostly used for its shielding properties in the nuclear power plants. These properties can already be influenced by the selection of the input materials. In the present study, concrete samples comprised of four-component binders based on CEM I 42.5 R, blast furnace slag, metakaolin and limestone and a mixture of barite and magnetite aggregate, were investigated. Based on Energy Dispersive X-ray Fluorescence, Neutron Activation, and Prompt-Gamma Activation analyses, three concrete designs were prepared and tested. Mechanical, physical (namely cubic compressive strength, bulk density, longitudinal deformation, and dynamic modulus of elasticity) and thermal properties (thermal conductivity coefficient, specific heat capacity, and thermal diffusivity), which should be influenced by the long-term exposure to irradiation were investigated. Presented results confirmed that the prepared samples are heavyweight concrete with bulk density higher than 3400 kg.m-3 with a low level of longitudinal deformation (between 0.265 ‰ and 0.352 ‰). All the prepared samples belong to the C 35/45 concrete strength class.

2008 ◽  
Vol 2008 ◽  
pp. 1-7 ◽  
Author(s):  
Mantas Povilaitis ◽  
Egidijus Urbonavičius

An issue of the stratified atmospheres in the containments of nuclear power plants is still unresolved; different experiments are performed in the test facilities like TOSQAN and MISTRA. MASPn experiments belong to the spray benchmark, initiated in the containment atmosphere mixing work package of the SARNET network. The benchmark consisted of MASP0, MASP1 and MASP2 experiments. Only the measured depressurisation rates during MASPn were available for the comparison with calculations. When the analysis was performed, the boundary conditions were not clearly defined therefore most of the attention was concentrated on MASP0 simulation in order to develop the nodalisation scheme and define the initial and boundary conditions. After achieving acceptable agreement with measured depressurisation rate, simulations of MASP1 and MASP2 experiments were performed to check the influence of sprays. The paper presents developed nodalisation scheme of MISTRA for the COCOSYS code and the results of analyses. In the performed analyses, several parameters were considered: initial conditions, loss coefficient of the junctions, initial gradients of temperature and steam volume fraction, and characteristic length of structures. Parametric analysis shows that in the simulation the heat losses through the external walls behind the lower condenser installed in the MISTRA facility determine the long-term depressurisation rate.


Author(s):  
Congjian Wang ◽  
Diego Mandelli ◽  
Shawn St Germain ◽  
Curtis Smith ◽  
David Morton ◽  
...  

Abstract As commercial nuclear power plants (NPPs) pursue extended plant operations in the form of Second License Renewals (SLRs), opportunities exist for these plants to provide capital investments to ensure long-term, safe, and economic performance. Several utilities have already announced their intention to pursue extended operations for one or more of their NPPs via SLR2. The goal of this research is to develop a risk-informed approach to evaluate and prioritize plant capital investments made in preparation for, and during the period of, extended plant operations to support decisions in NPP operations. In order to prioritize project selection via a risk-informed approach we developed a single decision-making tool that integrates safety/reliability, cost, and stochastic optimization models to provide users with data analysis capabilities to more cost effectively manage plant assets. Both stochastic analysis methods — such as Monte Carlo-based sampling strategies — and multi-stage stochastic optimization strategies are employed to provide priority lists to decision-makers in support of risk-informed decisions. We applied the proposed method to a trial application of projected replacement/refurbishment expenditures for plant capital assets (i.e., structures, systems, and components [SSCs]). The objective is to optimize the SSC replacement/refurbishment schedule in terms of economic constraints, data uncertainties, and SSC reliability data, as well to generate a priority list for maximizing returns on investment.


2019 ◽  
Vol 186 (4) ◽  
pp. 524-529
Author(s):  
Si Young Kim

Abstract The intercomparison test is a quality assurance activity performed for internal dose assessment. In Korea, the intercomparison test on internal dose assessment was carried out for nuclear facilities in May 2018. The test involved four nuclear facilities in Korea, and seven exposure scenarios were applied. These scenarios cover the intake of 131I, a uranium mixture, 60Co and tritium under various conditions. This paper only reviews the participant results of three scenarios pertinent to the operation of nuclear power plants and adopts the statistical evaluation method, used in international intercomparison tests, to determine the significance values of the results. Although no outliers were established in the test, improvements in the internal dose assessment procedure were derived. These included the selection of intake time, selection of lung absorption type according to the chemical form and consideration of the contribution of previous intake.


2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Mauro Cappelli ◽  
Francesco Cordella ◽  
Francesco Bertoncini ◽  
Marco Raugi

Guided wave (GW) testing is regularly used for finding defect locations through long-range screening using low-frequency waves (from 5 to 250 kHz). By using magnetostrictive sensors, some issues, which usually limit the application to nuclear power plants (NPPs), can be fixed. The authors have already shown the basic theoretical background and simulation results concerning a real steel pipe, used for steam discharge, with a complex structure. On the basis of such theoretical framework, a new campaign has been designed and developed on the same pipe, and the obtained experimental results are now here presented as a useful benchmark for the application of GWs as nondestructive techniques. Experimental measures using a symmetrical probe and a local probe in different configurations (pulse-echo and pitch-catch) indicate that GW testing with magnetostrictive sensors can be reliably applied to long-term monitoring of NPPs components.


1996 ◽  
Vol 118 (3) ◽  
pp. 340-346 ◽  
Author(s):  
S. Jahanian

In pressure vessel technology or nuclear power plants, some of the mechanical components are often subjected to rapid heating. If the temperature gradient during such process is high enough, thermoelastoplastic stresses may be developed in the components. These plastic deformations are permanent and may result in the incremental deformation of the structure in the long term. Accordingly, determination of thermoelastoplastic stresses during this process is an important factor in design. In this paper, a thick-walled cylinder of nonlinear strain hardening is considered for the thermoelastoplastic analysis. The properties of the material are assumed to be temperature dependent. The cylinder is subject to rapid heating of the inside surface while the outside surface is kept at the room temperature. A quasi-static and uncoupled thermoelastoplastic analysis based on incremental theory of plasticity is developed and a numerical procedure for successive elastic approximation is presented. The thermoelastoplastic stresses developed during this process are also presented. The effect of strain hardening and temperature dependency of material on the results are investigated.


Author(s):  
J. Douglas Hill ◽  
Paul Moore

Nuclear power plants rely on Instrumentation and Control (I&C) systems for control, monitoring and protection of the plant. The original, analog designs used in most nuclear plants have become or soon will be obsolete, forcing plants to turn to digital technology. Many factors affect the design of replacement equipment, including long-term and short-term economics, regulatory issues, and the way the plant operates on a day-to-day basis. The first step to all modernization projects should involve strategic planning, to ensure that the overall long and short-term goals of the plant are met. Strategic planning starts with a thorough evaluation of the existing plant control systems, the available options, and the benefits and consequences of these options.