scholarly journals Repeated biopsy in the detection of prostate cancer: When and how many cores

2014 ◽  
Vol 86 (4) ◽  
pp. 311 ◽  
Author(s):  
Vincenzo Scattoni ◽  
Andrea Russo ◽  
Ettore Di Trapani ◽  
Umberto Capitanio ◽  
Giovanni La Croce ◽  
...  

Purpose: We performed an analysis of the literature about the optimal prostate biopsy (PBX) scheme in the repeated setting Methods: We performed a clinical and critical literature review by searching Medline Database from January 2005 up to January 2014. Electronic searches were limited to the English language. The keywords were: prostate cancer, prostate biopsy, transrectal ultrasound, transperineal prostate biopsy. Results: The recommended approach in repeated setting is still the extended scheme (EPBx) (12 cores). An approach with more than 12 cores according to the clinical characteristics of the patients may optimize cancer detection. Saturation PBx (> 20 cores) clearly improves cancer detection if clinical suspicion persists after previous negative biopsy. Nevertheless international guidelines do not strongly recommended SPBx in all situations of repeated setting. EPBx or SPBX may be, in the future, substituted by multiparametric MRI-targeted biopsies. Conclusions: Since the scenario in which a PBx is changing, the issue about the number and location of the cores in PBx is still a matter of debate in repeated setting. At present, EPBx are still the gold standard even if SPBx seems to be necessary in many cases. However, random PBx does not represent the approach of the future, but rather imaging targeted biopsy.

Medicina ◽  
2021 ◽  
Vol 57 (1) ◽  
pp. 57
Author(s):  
Alvydas Vėželis ◽  
Gediminas Platkevičius ◽  
Marius Kinčius ◽  
Liutauras Gumbys ◽  
Ieva Naruševičiūtė ◽  
...  

Background and objectives: Overdiagnosis, overtreatment, and the need for repeated procedures caused by transrectal ultrasound guided prostate biopsies and their related complications places a heavy burden on healthcare systems. This was a prospective cohort validating study to access the clinical accuracy of systematic and MRI-cognitive targeted transperineal prostate biopsies in detecting clinically significant prostate cancer after a previous negative biopsy and persistent suspicion of malignancy. The primary goal was to assess the ability of multiparametric magnetic resonance imaging (mpMRI) to detect clinically significant prostate cancer with an additional goal to assess the diagnostic value of systematic and MRI-cognitive transperineal biopsies. Materials and Methods: In total, 200 patients were enrolled who had rising serum prostate specific antigen (PSA) levels for at least 4 months after a previous negative transrectal ultrasound (TRUS) biopsy. All eligible men underwent 1.5T prostate mpMRI, reported using the Prostate Imaging Reporting and Data System version 2 (PI-RADS v2), followed by a 20-region transperineal prostate systematic biopsy and additional targeted biopsies. Results: Systematic 20-core transperineal prostate biopsies (TPBs) were performed for 38 (19%) patients. Systemic 20-core TPB with additional cognitive targeted biopsies were performed for 162 (81%) patients. Clinically significant prostate cancer (csPC) was detected for 31 (15.5%) patients, of which 20 (64.5%) cases of csPC were detected by systematic biopsy, eight (25.8%) cases were detected by targeted biopsy, and three (9.7%) both by systematic and targeted biopsies. Conclusions: Cognitive mpMRI guided transperineal target biopsies increase the detection rate of clinically significant prostate cancer after a previously negative biopsy. However, in a repeat prostate biopsy setting, we recommend applying a cognitive targeted biopsy with the addition of a systematic biopsy.


BMC Urology ◽  
2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Lei Wang ◽  
Xiaofei Wang ◽  
Wenfeng Zhao ◽  
Zichen Zhao ◽  
Zhihu Li ◽  
...  

Abstract Background To report a new standardized cognitive fusion technique on transperineal targeted biopsy (TB) of prostate, and to evaluate its efficacy for cancer detection combined with systematic biopsy (SB) . Methods We present a retrospective review of consecutive patients undergoing multiparametric magnetic resonance (mpMRI) imaging of the prostate with subsequent transperineal prostate biopsy from January 2016 to December 2018. A free-hand 12-core SB was performed for each patient. PI-RADS 3–5 lesions were further targeted for biopsy with our TB technique. Firstly, a central point of suspicious lesion (B′) was registered cognitively on a transverse section of transrectal ultrasound (TRUS). Then, biopsy gun punctured vertically through a fixed pioneer site (A) on skin of perineum, and deep into the TRUS section to get A’. Next, targeted site (B), the surface-projection of B′, would be determined on skin of perineum by A and distance from B′ to A’. Finally, puncture through B to reach B′. Pathological findings of SB and TB were analyzed. Results A total of 126 patients underwent transperineal prostate biopsy (47 SB only, 79 SB + TB). The age of the patients was 68.7 ± 9.2 years. The median preoperative PSA value was 11.8 ng/mL. Preoperative prostate volume was 60.5 ± 50.0 mL. The numbers of patients with PI-RADS scores of 1 through 5 were 4, 43, 27, 21 and 31, respectively. The overall detection rate of cancer was 61/126 (48.4%), and it was significantly higher in the combination cohort (56/79, 70.9%) compared with the SB only cohort (5/47, 10.6%, p<0.001). When focused on the combination cohort, TB detected a similar overall rate of PCa (53/79, 67.1% vs 52/79, 65.8%; p = 0.87) compared with SB. The clinically significant PCa (csPC) detection rate was 52/79 (65.8%), while for TB and SB the csPC/PC rate was 51/53 (96.2%) and 48/52 (92.3%), respectively(p = 0.44). TB demonstrated a better sampling performance (positive rate for each core) compared with SB (51.0% vs 31.3%, p < 0.001). Conclusions Surface-projection-based transperineal cognitive fusion targeted biopsy of the prostate has a good efficacy in detecting PCa.


2017 ◽  
Vol 89 (3) ◽  
pp. 245 ◽  
Author(s):  
Andrea Fabiani ◽  
Emanuele Principi ◽  
Alessandra Filosa ◽  
Lucilla Servi

Dear Editors,We read with interest the article by Di Franco and co-workers (1). The introduction of prostatic magnetic resonance and the relative fusion-biopsy have not yet allowed the expected improvements in prostate biopsy. To our knowledge, there are no works that demonstrate the superiority of fusion techniques on the remaining ultrasound guided prostate biopsies that are still the widely used in the diagnosis of prostate cancer. Furthemore, these technologies are expensive exams and they are not yet available in all centers, especially in those minors. We work at a “minor” center and we always keep in mind that the goal of  prostatic biopsy is the diagnosis and the staging of prostatic neoplasms.. However, it remains uncertain which of the two techniques, transperineal (TP) or transrectal (TR), is superior in terms of detection rate during first biopsy setting. Several studies have compared the prostate cancer detection rate but TR and TP access route in prostatic gland sampling seems to be equivalent in terms of efficiency and complications, as reported by Shen PF et al. (2), despite several methodological limitations recognized in their work. The results reported by Di Franco CA et al. represent the real life experience of most urologists that perform the PB based on their own training experience and available technical devices. From an historical viewpoint, the TP route has been the first one to be used to reach the prostate, both for diagnostic and therapeutic purposes. To date, because it seems to be more invasive and difficult, the TP route is less used worldwide than the TR one (2). Theoretically, the TP approach should detect more prostate cancer than the TR way  because the cores of the TP approach are directed longitudinally to the peripheral zone and the anterior part of the prostate (4). The results reported by Di Franco et al. seems to confirm these considerations. However, our real life experience differ from the conclusions reached in their work. We recently conducted a prospective evaluation of 352 patients who underwent their first prostate biopsy because of a suspicious of prostate cancer (elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination and/or abnormal findings on transrectal prostatic ultrasound). Patients was randomized as following. A total of 187 patients (Group A) underwent a prostatic biopsy with a transperineal approach in a lithotomic position,  using a biplane probe (8818 BK Medical, Denmark) and a fan technique with a single perineal median access (5). The remnants 165 patients (Group B) underwent a transrectal ultrasound guided prostate biopsy in a left lateral position, using a end fire probe configuration (8818 BK Medical, Denmark) and a sagittal technique. The bioptic prostatic mapping was performed with a 12-core scheme sec. Gore (3) by a single experienced operator and the histopathologic evaluation was performed by a single dedicated uro-pathologist. Statistical evaluations were made with a T Student test  (p<0,005). Group A and Group B was similar in term of mean patient age (67,9 years and 67 years respectively), mean total PSA (12,1 ng/ml vs 12 ng/ml) and digital rectal examination positivity (22% vs 29%).  The global cancer detection rate was 33,69% (63/187) in the transperineal prostate biopsy group and 48,48 % (80/165) in the transrectal approach (p=0.0047).  No significant statistical differences were found in the complications rates between the two groups. Statistical evaluation of site of tumor localization reveal only a trend to statistical significance in apical site tumors diagnosed with the TR approach versus the TP technique. The TR approach had a better diagnostic accuracy than TP technique in case of PSA<4 ng/ml, intermediate prostate volume (30 and 50 ml), normal digital rectal examination without any relationship with the patient age. In our experience, two aspect may explain the difference between the two group in term of global detection rate. First, we usually perform transrectal biopsy with a sagittal technique that simulates the transperineal way of needle incidence with the prostatic gland. The lateral and anterior gland portions may be sampled more accurately. Second, our transperineal approach consists in a single perineal median access that can make more difficult the gland sampling between the two lobes. However, there was no significant difference in core positivity rate at the peripheral zone, medium gland, apex or any other site such as reported in many randomized clinical trials (2). Unlike the conclusions reported by Di Franco et al., in our experience we found a statistically significant difference between the TR and TP approach, at the first biopsy setting, in term of global cancer detection rate. No differences were found in terms of complications. Moreover, our data suggest that TR approach had a better diagnostic accuracy than TP technique in case of  PSA<4 ng/ml, prostate volume 30-50 ml, normal digital rectal examination without any relationship with the patient age. The further step of the statistical evaluation of our data will be the definition of the possibility that the TR biopsy determine a better staging of prostate cancer than TP approach as first procedure.    REFERENCES 1)      Di Franco CA, Jallous H., Porru D. et al. A retrospective comparison between transrectal and transperineal prostate biopsy in the detection of prostate cancer Arch Ital Urol Androl 2017; 89(1), 55-92)      Shen FP, Zhu YC, Wei WR et al. The results of transperineal vs transrectal prostate biopsy: a systematic review and meta-analysis. Asian Journal of Androl 2012; 14: 310-15.3)      Gore JL., Shariat SF, Miles BJ., et al. Optimal combinations of systematic sextant and laterally directed biopsies for the detection of prostate cancer. J Urol 2001; 165: 1554-59.  4)      Abdollah F., Novara G., Briganti A. et al. Trasrectal versus transperineal saturation re biopsy of the prostate: is there a difference in cancer detection rate? Urology 2011; 77:9215)      Novella G, Ficarra V, Galfano A, et al. Pain assessment after original transperineal prostate biopsy using a coaxial needle. Urology. 2003; 62 : 689-92. 


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Alexandre Peltier ◽  
Fouad Aoun ◽  
Fouad El-Khoury ◽  
Eric Hawaux ◽  
Ksenija Limani ◽  
...  

Objectives. To compare prostate cancer detection rates of extended 2D versus 3D biopsies and to further assess the clinical impact of this method in day-to-day practice.Methods. We analyzed the data of a cohort of 220 consecutive patients with no prior history of prostate cancer who underwent an initial prostate biopsy in daily practice due to an abnormal PSA and/or DRE using, respectively, the classical 2D and the new 3D systems. All the biopsies were done by a single experienced operator using the same standardized protocol.Results. There was no significant difference in terms of age, total PSA, or prostate volume between the two groups. However, cancer detection rate was significantly higher using the 3D versus the 2D system, 50% versus 34% (P<0.05). There was no statistically significant difference while comparing the 2 groups in term of nonsignificant cancer detection.Conclusion. There is reasonable evidence demonstrating the superiority of the 3D-guided biopsies in detecting prostate cancers that would have been missed using the 2D extended protocol.


2021 ◽  
Vol 25 (2) ◽  
pp. 138-152
Author(s):  
G. A. Gulin ◽  
A. V. Zyryanov ◽  
N. A. Rubtsova ◽  
V. M. Artyemov ◽  
A. V. Zamyatin ◽  
...  

Multiparametric MRI (mpMRI) has superb sensitivity in prostate cancer detection. mpMRI is increasingly used not only for primary diagnostics, but for location of suspicious lesion before biopsy in case of targeted biopsy (TB). In many recent studies have been shown higher level of TB accuracy in prostate cancer detection in comparison with traditional systemic biopsy. In recent EAU, NICE, ACR recommendations mpMRI is indicated for men with high level of prostate cancer suspicion with previous negative results of systemic biopsy. However, it is not absolutely clear, whether mpMRI is indicated for biopsy-naïve men. This study is dedicated for prostate biopsy planning in the groups of biopsy-naïve men and with the history of previous biopsy.


Cancers ◽  
2021 ◽  
Vol 13 (19) ◽  
pp. 4833
Author(s):  
Andrea Fulco ◽  
Francesco Chiaradia ◽  
Luigi Ascalone ◽  
Vincenzo Andracchio ◽  
Antonio Greco ◽  
...  

The management of prostate biopsy in men with clinical suspicion of prostate cancer has changed in the last few years, especially with the introduction of imaging techniques, to overcome the low efficacy of risk stratification based on PSA levels. Here, we aimed to compare the diagnostic accuracy of multiparametric MRI with fusion ultrasound-guided prostate biopsy and standard biopsy, both performed through the transperineal route. To this end, we retrospectively analyzed 272 patients who underwent combined transperineal targeted and standard biopsy during the same session. The primary outcome was to compare the cancer detection rate between targeted and standard biopsy. The secondary outcome was to evaluate the added value of combined targeted and standard biopsy approach as compared to only targeted or standard biopsy. Results showed that a rate of 16.7% clinically significant tumors (International Society of Urological Pathology (ISUP) grade ≥ 2) would have been lost if only the standard biopsy had been used. The combined targeted and standard biopsy showed an added value of 10.3% and 9.9% in reducing the risk of prostate cancer missing after targeted or standard biopsy alone, respectively. The combined targeted and standard biopsy pathway is recommended to reduce the risk of missing clinically significant prostate cancer.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Alexandre Peltier ◽  
Fouad Aoun ◽  
Marc Lemort ◽  
Félix Kwizera ◽  
Marianne Paesmans ◽  
...  

Introduction. To compare, in the same cohort of men, the detection of clinically significant disease in standard (STD) cores versus multiparametric magnetic resonance imaging (mpMRI) targeted (TAR) cores.Material and Methods. A prospective study was conducted on 129 biopsy naïve men with clinical suspicion of prostate cancer. These patients underwent prebiopsy mpMRI with STD systematic biopsies and TAR biopsies when lesions were found. The agreement between the TAR and the STD protocols was measured using Cohen’s kappa coefficient.Results. Cancer detection rate of MRI-targeted biopsy was 62.7%. TAR protocol demonstrated higher detection rate of clinically significant disease compared to STD protocol. The proportion of cores positive for clinically significant cancer in TAR cores was 28.9% versus 9.8% for STD cores (P<0.001). The proportion of men with clinically significant cancer and the proportion of men with Gleason score 7 were higher with the TAR protocol than with the STD protocol (P=0.003;P=0.0008, resp.).Conclusion. mpMRI improved clinically significant prostate cancer detection rate compared to STD protocol alone with less tissue sampling and higher Gleason score. Further development in imaging as well as multicentre studies using the START recommendation is needed to elucidate the role of mpMRI targeted biopsy in the management of prostate cancer.


Sign in / Sign up

Export Citation Format

Share Document