Accuracy of the freehand (fennell) technique using a uniform entry point and sagittal trajectory for insertion of thoracic pedicle screws: A computed tomography-based virtual simulation study

2020 ◽  
Vol 68 (2) ◽  
pp. 468
Author(s):  
BaylisVivek Joseph ◽  
Ganesh Swaminathan ◽  
Vetrivel Muralidharan ◽  
Devadhas Devakumar
2007 ◽  
Vol 7 (5) ◽  
pp. 36S ◽  
Author(s):  
Jahangir Asghar ◽  
David Clements ◽  
Joshua Pahys ◽  
Amer Samdani ◽  
Linda D'Andrea ◽  
...  

Neurosurgery ◽  
2011 ◽  
Vol 69 (4) ◽  
pp. 782-795 ◽  
Author(s):  
Kai-Michael Scheufler ◽  
Joerg Franke ◽  
Anke Eckardt ◽  
Hildegard Dohmen

Abstract BACKGROUND: Image-guided spinal instrumentation reduces the incidence of implant misplacement. OBJECTIVE: To assess the accuracy of intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS: In 35 patients (age range, 18-87 years), a total of 248 pedicle screws were placed in the cervical (C1-C7) and upper and midthoracic (T1-T8) spine. An automated iCT registration sequence was used for multisegmental instrumentation, with the reference frame fixed to either a Mayfield head clamp and/or the most distal spinous process within the instrumentation. Pediculation was performed with navigated drill guides or Jamshidi cannulas. The angular deviation between navigated tool trajectory and final implant positions (evaluated on postinstrumentation iCT or postoperative CT scans) was calculated to assess the accuracy of iCT-N. Final screw positions were also graded according to established classification systems. Mean follow-up was 16.7 months. RESULTS: Clinically significant screw misplacement or iCT-N failure mandating conversion to conventional technique did not occur. A total of 71.4% of patients self-rated their outcome as excellent or good at 12 months; 99.3% of cervical screws were compliant with Neo classification grades 0 and 1 (grade 2, 0.7%), and neurovascular injury did not occur. In addition, 97.8% of thoracic pedicle screws were assigned grades I to III of the Heary classification, with 2.2% grade IV placement. Accuracy of iCT-N progressively deteriorated with increasing distance from the spinal reference clamp but allowed safe instrumentation of up to 10 segments. CONCLUSION: Image-guided spinal instrumentation using iCT-N with automated referencing allows safe, highly accurate multilevel instrumentation of the cervical and upper and midthoracic spine. In addition, iCT-N significantly reduces the need for reregistration in multilevel surgery.


2011 ◽  
Vol 15 (5) ◽  
pp. 479-485 ◽  
Author(s):  
Yuichiro Abe ◽  
Manabu Ito ◽  
Kuniyoshi Abumi ◽  
Yoshihisa Kotani ◽  
Hideki Sudo ◽  
...  

Object Use of computer-assisted spine surgery (CASS) technologies, such as navigation systems, to improve the accuracy of pedicle screw (PS) placement is increasingly popular. Despite of their benefits, previous CASS systems are too expensive to be ubiquitously employed, and more affordable and portable systems are desirable. The aim of this study was to introduce a novel and affordable computer-assisted technique that 3-dimensionally visualizes anatomical features of the pedicles and assists in PS insertion. The authors have termed this the 3D-visual guidance technique for inserting pedicle screws (3D-VG TIPS). Methods The 3D-VG technique for placing PSs requires only a consumer-class computer with an inexpensive 3D DICOM viewer; other special equipment is unnecessary. Preoperative CT data of the spine were collected for each patient using the 3D-VG TIPS. In this technique, the anatomical axis of each pedicle can be analyzed by volume-rendered 3D models, as with existing navigation systems, and both the ideal entry point and the trajectory of each PS can be visualized on the surface of 3D-rendered images. Intraoperative guidance slides are made from these images and displayed on a TV monitor in the operating room. The surgeon can insert PSs according to these guidance slides. The authors enrolled 30 patients with adolescent idiopathic scoliosis (AIS) who underwent posterior fusion with segmental screw fixation for validation of this technique. Results The novel technique allowed surgeons, from office or home, to evaluate the precise anatomy of each pedicle and the risks of screw misplacement, and to perform 3D preoperative planning for screw placement on their own computer. Looking at both 3D guidance images on a TV monitor and the bony structures of the posterior elements in each patient in the operating theater, surgeons were able to determine the best entry point for each PS with ease and confidence. Using the current technique, the screw malposition rate was 4.5% in the thoracic region in corrective surgery for AIS. Conclusions The authors found that 3D-VG TIPS worked on a consumer-class computer and easily visualized the ideal entry point and trajectory of PSs in any operating theater without costly special equipment. This new technique is suitable for preoperative planning and intraoperative guidance when performing reconstructive surgery with PSs.


2014 ◽  
Vol 21 (5) ◽  
pp. 778-784 ◽  
Author(s):  
Vernard S. Fennell ◽  
Sheri Palejwala ◽  
Jesse Skoch ◽  
David A. Stidd ◽  
Ali A. Baaj

Object Experience with freehand thoracic pedicle screw placement is well described in the literature. Published techniques rely on various starting points and trajectories for each level or segment of the thoracic spine. Furthermore, few studies provide specific guidance on sagittal and axial trajectories. The goal of this study was to propose a uniform entry point and sagittal trajectory for all thoracic levels during freehand pedicle screw placement and determine the accuracy of this technique. Methods The authors retrospectively reviewed postoperative CT scans of 33 consecutive patients who underwent open, freehand thoracic pedicle-screw fixation using a uniform entry point and sagittal trajectory for all levels. The same entry point for each level was defined as a point 3 mm caudal to the junction of the transverse process and the lateral margin of the superior articulating process, and the sagittal trajectory was always orthogonal to the dorsal curvature of the spine at that level. The medial angulation (axial trajectory) was approximately 30° at T-1 and T-2, and 20° from T-3 to T-12. Breach was defined as greater than 25% of the screw diameter residing outside of the pedicle or vertebral body. Results A total of 219 thoracic pedicle screws were placed with a 96% accuracy rate. There were no medial breaches and 9 minor lateral breaches (4.1%). None of the screws had to be repositioned postoperatively, and there were no neurovascular complications associated with the breaches. Conclusions It is feasible to place freehand thoracic pedicle screws using a uniform entry point and sagittal trajectory for all levels. The entry point does not have to be adjusted for each level as reported in existing studies, although this technique was not tested in severe scoliotic spines. While other techniques are effective and widely used, this particular method provides more specific parameters and may be easier to learn, teach, and adopt.


Sign in / Sign up

Export Citation Format

Share Document