scholarly journals Magnetic Resonance-guided Focused Ultrasound Treatment for Uterine Fibroids: First Study in Indian Women

2012 ◽  
Vol 2 ◽  
pp. 74 ◽  
Author(s):  
Shrinivas B. Desai ◽  
Abhijit A. Patil ◽  
Rahul Nikam ◽  
Ajinkya S. Desai ◽  
Vrushali Bachhav

Objectives: To study the results of magnetic resonance-guided focused ultrasound surgery (MRgFUS) treatment carried out on Indian patients in our Hospital. Materials and Methods: Fifty Indian women (mean age = 36.2 ± 8.3 years) were treated for fibroids as outpatients using the ExAblate MRgFUS system (InSightec). Non-perfused volumes (NPVs) were measured immediately after treatment to calculate the treatment outcomes. A validated symptom-specific questionnaire to record their symptoms prior to treatment and six months following treatment was completed by patients. The size of the fibroids was measured on the day of the treatment and during the 6-month checkup to calculate shrinkage. Adverse events during and following treatment were recorded and monitored. Results: The average NPV ratio measured after the treatment was 88% ± 6%, indicative of high ablated fibroid tissue. Prior to treatment, the mean Symptoms Severity Score was 56.9 ± 4.8 (n = 50), which is indicative of highly symptomatic patients. Six months following treatment, there was an average fibroid shrinkage of 30% ± 11%, and a significant decrease in the mean score to 28.6 ± 6.0 (n = 50) (P < 0.001). There were no reports of serious or unexpected adverse events at any point during treatment or during the follow-up period from any of the 50 women treated in the current study. Conclusions: The current results obtained after 6 months of treatment corroborated previous data on the safety and efficacy of MRgFUS for treating uterine fibroids. This is the first publication that provides such data for a large cohort of Indian women.

2021 ◽  
Vol 14 ◽  
Author(s):  
Kyung Won Chang ◽  
Itay Rachmilevitch ◽  
Won Seok Chang ◽  
Hyun Ho Jung ◽  
Eyal Zadicario ◽  
...  

ObjectiveMagnetic resonance-guided focused ultrasound surgery (MRgFUS) lesioning is a new treatment for brain disorders. However, the skull is a major barrier of ultrasound sonication in MRgFUS because it has an irregular surface and varies its size and shape among individuals. We recently developed the concept of skull density ratio (SDR) to select candidates for MRgFUS from among patients with essential tremor (ET). However, SDR is not the only factor contributing to successful MRgFUS lesioning treatment—refining the target through exact measurement of the ultrasonic echo in the transducer also improves treatment efficacy. In the present study, we carried out MRgFUS lesioning using an autofocusing echo imaging technique. We aimed to evaluate the safety and efficacy of this new approach, especially in patients with low SDR in whom previous focusing methods have failed.MethodsFrom December 2019 to March 2020, we recruited 10 patients with ET or Parkinson’s disease (PD) who had a low SDR. Two patients dropped out of the trial due to the screening failure of other medical diseases. In total, eight patients were included: six with ET who underwent MRgFUS thalamotomy and two with PD who underwent MRgFUS pallidotomy. The autofocusing echo imaging technique was used in all cases.ResultsThe mean SDR of the patients with ET was 0.34 (range: 0.29–0.39), while that of the patients with PD was 0.41 (range: 0.38–0.44). The mean skull volume of patients with ET was 280.57 cm3 (range: 227–319 cm3), while that of the patients with PD was 287.13 cm3 (range: 271–303 cm3). During MRgFUS, a mean of 15 sonications were performed, among which a mean of 5.63 used the autofocusing technique. The mean maximal temperature (Tmax) achieved was 55.88°C (range: 52–59°C), while the mean energy delivered was 34.75 kJ (range: 20–42 kJ) among all patients. No serious adverse events occurred during or after treatment. Tmax or sonication factors (skull volume, SDR, sonication number, autofocusing score, similarity score, energy range, and power) were not correlated with autofocusing technique (p &gt; 0.05, autofocusing score showed a p-value of 0.071).ConclusionUsing autofocusing echo imaging lesioning, a safe and efficient MRgFUS treatment, is available even for patients with a low SDR. Therefore, the indications for MRgFUS lesioning could be expanded to include patients with ET who have an SDR &lt; 0.4 and those with PD who have an SDR &lt; 0.45.Clinical Trial Registrationclinicaltrials.gov, identifier: NCT03935581.


2018 ◽  
Author(s):  
Bijan J. Borah ◽  
Elizabeth A. Stewart

Uterine leiomyomas (fibroids) affect 20–40% of reproductive age women and are the major indication for hysterectomy. Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a new, potentially disruptive, non-invasive and uterine-sparing treatment option that has been shown to yield similar or better clinical outcomes than other uterine-sparing interventions. However, the costs of MRgFUS and other minimally-invasive treatment options have not been studied using US practice data. This study attempts to fill this void. And since uterine fibroids are the first FDA-approved indication for MRgFUS treatment, this study may also have implications for other indications which are now investigational.


2010 ◽  
Vol 93 (1) ◽  
pp. 199-209 ◽  
Author(s):  
Jaron Rabinovici ◽  
Matthias David ◽  
Hidenobu Fukunishi ◽  
Yutaka Morita ◽  
Bobbie S. Gostout ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document