scholarly journals Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study

2017 ◽  
Vol 17 (4) ◽  
pp. 373 ◽  
Author(s):  
Sujana Ullattuthodi ◽  
KandathilPhillip Cherian ◽  
R Anandkumar ◽  
SreedeviR Nambiar
2017 ◽  
Vol 05 (01) ◽  
pp. 039-046 ◽  
Author(s):  
Monica Sharma ◽  
Ajay Bansal ◽  
Sunny Panthi ◽  
Shefali Malik ◽  
Atulya Sharma

Abstract Purpose: The purpose of this in vitro study was to evaluate marginal fit of cobalt- chromium (Co-Cr) copings fabricated by direct metal laser sintering system (DMLS) and conventional lost-wax technique (LW). Materials and method: Forty tooth preparations were carried out over extracted mandibular molars. They were divided into two groups A and B of 20 each. For group A Co-Cr copings were fabricated by direct metal laser sintering (DMLS) and for group B by lost wax technique (LW). Glass –ionomer cement (GIC) was used to tack the copings over their preparations. Marginal fit was then evaluated directly under the stereomicroscope. Results: The mean marginal gap of group A was 27.9 ± 2.4 μm and group B was 40.4 ±6 μm. Statistical analysis using t - test showed highly significant difference (P>.05) between the marginal mean of the DMLS (group A) compared to LW (group B). Conclusion: The DMLS copings demonstrated superior marginal fit compared to that of conventional Co-Cr casted copings.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2011 ◽  
Vol 36 (1) ◽  
pp. 72-79 ◽  
Author(s):  
L. Korkut ◽  
H. S. Cotert ◽  
H. Kurtulmus

Clinical Relevance Fitting accuracy and microleakage dominate prognostic covariates for the long-term durability of crown restorations. The fitting accuracy and microleakage potential of zirconia infrastructures might be influenced by manufacturing technology.


2005 ◽  
Vol 24 (3) ◽  
pp. 456-459 ◽  
Author(s):  
Takashi NAKAMURA ◽  
Hideaki TANAKA ◽  
Soichiro KINUTA ◽  
Takeshi AKAO ◽  
Kei OKAMOTO ◽  
...  

2017 ◽  
Vol 7 (10) ◽  
pp. 1008-1013
Author(s):  
Abdulaziz M. Albaker ◽  
Faisal M. Fahmi ◽  
Merna F. Fahmi ◽  
Abdullah M. Alfarraj Aldosari ◽  
Ishfaq A. Bukhari ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document