scholarly journals Experimental Study of Effective Thermal Conductivity of Fiber Assembly. Part 2: Model Analysis of Radiative Heat Transfer and Comparison with Experimental Results.

Author(s):  
Takako Fujimoto
Materials ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2626
Author(s):  
Aurelia Blazejczyk ◽  
Cezariusz Jastrzebski ◽  
Michał Wierzbicki

This article introduces an innovative approach to the investigation of the conductive–radiative heat transfer mechanism in expanded polystyrene (EPS) thermal insulation at negligible convection. Closed-cell EPS foam (bulk density 14–17 kg·m−3) in the form of panels (of thickness 0.02–0.18 m) was tested with 1–15 µm graphite microparticles (GMP) at two different industrial concentrations (up to 4.3% of the EPS mass). A heat flow meter (HFM) was found to be precise enough to observe all thermal effects under study: the dependence of the total thermal conductivity on thickness, density, and GMP content, as well as the thermal resistance relative gain. An alternative explanation of the total thermal conductivity “thickness effect” is proposed. The conductive–radiative components of the total thermal conductivity were separated, by comparing measured (with and without Al-foil) and simulated (i.e., calculated based on data reported in the literature) results. This helps to elucidate why a small addition of GMP (below 4.3%) forces such an evident drop in total thermal conductivity, down to 0.03 W·m−1·K−1. As proposed, a physical cause is related to the change in mechanism of the heat transfer by conduction and radiation. The main accomplishment is discovering that the change forced by GMP in the polymer matrix thermal conduction may dominate the radiation change. Hence, the matrix conduction component change is considered to be the major cause of the observed drop in total thermal conductivity of EPS insulation. At the microscopic level of the molecules or chains (e.g., in polymers), significant differences observed in the intensity of Raman spectra and in the glass transition temperature increase on differential scanning calorimetry(DSC) thermograms, when comparing EPS foam with and without GMP, complementarily support the above statement. An additional practical achievement is finding the maximum thickness at which one may reduce the “grey” EPS insulating layer, with respect to “dotted” EPS at a required level of thermal resistance. In the case of the thickest (0.30 m) panels for a passive building, above 18% of thickness reduction is found to be possible.


1981 ◽  
Vol 103 (1) ◽  
pp. 114-120 ◽  
Author(s):  
M. Epstein ◽  
F. B. Cheung ◽  
T. C. Chawla ◽  
G. M. Hauser

The effective thermal conductivity for radiative heat transfer within an optically thick fluid layer undergoing high Rayleigh number convection is derived. This result is combined with available “pure” free-convection heat-transfer correlations to obtain closed-form analytical descriptions of the gross properties of a radiating fluid layer heated internally or from below. These simple solutions compare favorably with recent work in which the governing energy equation incorporating both turbulent heat transport and thermal radiation is solved numerically.


Sign in / Sign up

Export Citation Format

Share Document