Ultrasonic Inspection, Thin Wall Metal Tubing

2011 ◽  
Author(s):  
2021 ◽  
Author(s):  
Niels Pörtzgen ◽  
Ola Bachke Solem

Abstract During the construction of pipelines for the transportation of oil and gas, the inspection of girth welds is a critical step to ensure the integrity and thereby the safety and durability of the pipeline. In this paper we present an advanced technology ‘IWEX’ for the non-destructive testing of welds based on 2D and 3D ultrasonic imaging. This technology allows for safe, fast, and accurate inspection whereby the results are presented comprehensively. This will be illustrated with results from a recent project. The IWEX technology is based on an ultrasonic inspection concept, whereby ‘fingerprints’ of ultrasonic signals are recorded, also referred to as ‘full matrix capture’ (FMC) data. Then, an image area is defined, consisting out of pixels over an area large enough to cover the inspection volume. With the FMC data, image amplitudes are calculated for each pixel so that the shape of geometry (back wall, front wall, cap, and root) and possible indications are revealed. As opposed to traditional ultrasonic testing strategies, the detection and sizing of indications is therefore less dependent on its orientation. The project concerned the inspection of J and V welds from a 5.56″ diameter carbon steel pipe with an 8.4mm wall thickness. The wall thickness is relatively thin compared to common inspection scopes. Therefore, the inspection set-up was adapted, and procedural changes were proposed. Consequently, additional validation efforts were required to demonstrate compliance with the required inspection standard; DNVGL-ST-F101: 2017. As part of this, welds were scanned with seeded indications and the reported locations were marked for macro slicing under witnessing of an independent representative from DNVGL. The resulting images from the indications in the welds showed great detail with respect to the position, orientation and height of the indications. A quantitative comparison with the results from the macro slices was performed, including a statistical analysis of the height sizing and depth positioning accuracies. From the analysis, it could be observed that the expected improvements with respect to the resolution and sizing accuracy were indeed achieved. Thereby, the procedure has proven to be adequate for the inspection of carbon steel girth welds within the thin wall thickness range (~6mm to ~15mm). The IWEX technology is a member of the upcoming inspection strategy based on imaging of ultrasonic FMC data. This strategy can be considered as the next step in the evolution of inspection strategies after phased array inspection. The IWEX technology has been witnessed and qualified by independent 3rd parties like DNVGL, this makes the IWEX technology unique in its kind and it opens opportunities for further acceptance in the industry and other inspection applications.


2021 ◽  
pp. 24-32
Author(s):  
Р.Р. Исхужин ◽  
В.Н. Борисов ◽  
В.Г. Атавин ◽  
А.А. Узких ◽  
К.К. Хафизова

The work considers the methodology of weld ultrasonic inspection of thin-wall (0.6 mm) titanium alloy shells. The paper also presents a review of publications on Lamb wave excitation and propagation, and on applications of ultrasonic inspection of thin-wall weldments. The problem of adhesion detection was successfully solved (weld zones with incomplete fusion conduct ultrasonic waves well, but do not provide mechanical strength). Angular groove is proposed as an indication of incomplete fusion in the weld. We analyzed different propagation modes of Lamb wave in the material and selected optimum inspection parameters. Wavelet analysis and precise digital filters with small increment provided great efficiency. Inspection results of corrupted weld and defect-free regions were analyzed. The results of ultrasonic scanning were compared to metallographic study data.


2015 ◽  
Vol 70 ◽  
pp. 287-291 ◽  
Author(s):  
Mihai Valentin Predoi ◽  
Cristian Cătălin Petre

Ultrasonics ◽  
1966 ◽  
Vol 4 (2) ◽  
pp. 57-63 ◽  
Author(s):  
J. Rooney ◽  
A. Reid

Author(s):  
J Downing ◽  
A Hook

Two steel substrate test panels were developed to represent common plate thicknesses found on naval vessels and scanned using the Babcock developed ultrasonic technique. One sample comprised of a series of slotted surface breaking flaws of varying widths and through thicknesses to represent fracturing/cracking. The inspection method detected simulated cracking to a depth of 2mm and 0.5mm in width. The second sample included numerous loss of wall thickness areas of varying diameters and through thicknesses, with the smallest detectable loss of wall thickness being 0.1mm at a 15mm diameter. After proving confidence in detection, there was a need to characterise flaws to provide support and ascertain a repair action. Samples were produced that were subjected to either impact or heat exposure to induce realistic representative damage. The practical ultrasonic method was successfully used to independently characterise between the samples, with induced de-laminations caused by blisters, and multi layered matrix cracking caused by varying levels of projectile impacts, due to their unique morphology.


2016 ◽  
Vol 58 (1) ◽  
pp. 75-78 ◽  
Author(s):  
Ali Rıza Yıldız ◽  
Enes Kurtuluş ◽  
Emre Demirci ◽  
Betul Sultan Yıldız ◽  
Selçuk Karagöz

Sign in / Sign up

Export Citation Format

Share Document