ultrasonic imaging
Recently Published Documents


TOTAL DOCUMENTS

1804
(FIVE YEARS 140)

H-INDEX

48
(FIVE YEARS 4)

2022 ◽  
pp. 650-658
Author(s):  
Hanyu Huo ◽  
Kai Huang ◽  
Wei Luo ◽  
Jintao Meng ◽  
Liangyi Zhou ◽  
...  

Micromachines ◽  
2022 ◽  
Vol 13 (1) ◽  
pp. 114
Author(s):  
Dongdong Chen ◽  
Xinhui Cui ◽  
Qidong Zhang ◽  
Di Li ◽  
Wenyang Cheng ◽  
...  

As traditional ultrasonic imaging systems (UIS) are expensive, bulky, and power-consuming, miniaturized and portable UIS have been developed and widely utilized in the biomedical field. The performance of integrated circuits (ICs) in portable UIS obviously affects the effectiveness and quality of ultrasonic imaging. In the ICs for UIS, the analog-to-digital converter (ADC) is used to complete the conversion of the analog echo signal received by the analog front end into digital for further processing by a digital signal processing (DSP) or microcontroller unit (MCU). The accuracy and speed of the ADC determine the precision and efficiency of UIS. Therefore, it is necessary to systematically review and summarize the characteristics of different types of ADCs for UIS, which can provide valuable guidance to design and fabricate high-performance ADC for miniaturized high resolution UIS. In this paper, the architecture and performance of ADC for UIS, including successive approximation register (SAR) ADC, sigma-delta (Σ-∆) ADC, pipelined ADC, and hybrid ADC, have been systematically introduced. In addition, comparisons and discussions of different types of ADCs are presented. Finally, this paper is summarized, and presents the challenges and prospects of ADC ICs for miniaturized high resolution UIS.


Author(s):  
Weiran Pang ◽  
Yongjun Wang ◽  
Lili Guo ◽  
Bo Wang ◽  
Puxiang Lai ◽  
...  

Existing acoustic-resolution photoacoustic/ultrasonic endoscopy (PA/USE) generally employs a point-focused transducer for ultrasound detection, which is only sensitive in its focal region, thus the lateral resolution and sensitivity drop dramatically when the targets move far from its focus. Even if a dynamic focusing algorithm is applied, the sensitivity out of the transducer focus is still much lower than that in the focus in ultrasonic imaging mode. In this work, we propose an acoustic-resolution PA/USE with a line-focused transducer to realize automatic focusing for the first time. In comparison to a point-focused transducer, the line-focused transducer emits a more uniform sound field, causing the original signal intensity and signal-to-noise ratio (SNR) of the front and rear targets to be closer in the radial direction, which is beneficial for improving target signal uniformity in ultrasonic imaging. Simultaneously, we improved the resolution of the defocus area by modifying a prior work of back-projection (BP) reconstruction algorithm typically used in point-focused transducer based PAE and applying it to line-focused PA/USE. This combined approach may significantly enhance the depth of field of ultrasonic imaging and the resolution of the defocus zone in PA/US imaging, compared to the conventional method. Sufficient numerical simulations and phantom experiments were performed to verify this method. The results show that our method can effectively improve the lateral resolution in the image’s defocused region to achieve automatic focusing and perfectly solve the defect of the target signal difference in the far-focus region in ultrasonic imaging, while also enhancing the image SNR and contrast. The proposed method in this paper lays foundations for the realization of photoacoustic/ultrasonic combined endoscopy with enhanced lateral resolution and depth of field, which can potentially benefit a many of biomedical applications.


2022 ◽  
Vol 163 ◽  
pp. 108144
Author(s):  
Jing Rao ◽  
Jilai Wang ◽  
Stefan Kollmannsberger ◽  
Jianfeng Shi ◽  
Hailing Fu ◽  
...  

2021 ◽  
Author(s):  
Niels Pörtzgen ◽  
Ola Bachke Solem

Abstract During the construction of pipelines for the transportation of oil and gas, the inspection of girth welds is a critical step to ensure the integrity and thereby the safety and durability of the pipeline. In this paper we present an advanced technology ‘IWEX’ for the non-destructive testing of welds based on 2D and 3D ultrasonic imaging. This technology allows for safe, fast, and accurate inspection whereby the results are presented comprehensively. This will be illustrated with results from a recent project. The IWEX technology is based on an ultrasonic inspection concept, whereby ‘fingerprints’ of ultrasonic signals are recorded, also referred to as ‘full matrix capture’ (FMC) data. Then, an image area is defined, consisting out of pixels over an area large enough to cover the inspection volume. With the FMC data, image amplitudes are calculated for each pixel so that the shape of geometry (back wall, front wall, cap, and root) and possible indications are revealed. As opposed to traditional ultrasonic testing strategies, the detection and sizing of indications is therefore less dependent on its orientation. The project concerned the inspection of J and V welds from a 5.56″ diameter carbon steel pipe with an 8.4mm wall thickness. The wall thickness is relatively thin compared to common inspection scopes. Therefore, the inspection set-up was adapted, and procedural changes were proposed. Consequently, additional validation efforts were required to demonstrate compliance with the required inspection standard; DNVGL-ST-F101: 2017. As part of this, welds were scanned with seeded indications and the reported locations were marked for macro slicing under witnessing of an independent representative from DNVGL. The resulting images from the indications in the welds showed great detail with respect to the position, orientation and height of the indications. A quantitative comparison with the results from the macro slices was performed, including a statistical analysis of the height sizing and depth positioning accuracies. From the analysis, it could be observed that the expected improvements with respect to the resolution and sizing accuracy were indeed achieved. Thereby, the procedure has proven to be adequate for the inspection of carbon steel girth welds within the thin wall thickness range (~6mm to ~15mm). The IWEX technology is a member of the upcoming inspection strategy based on imaging of ultrasonic FMC data. This strategy can be considered as the next step in the evolution of inspection strategies after phased array inspection. The IWEX technology has been witnessed and qualified by independent 3rd parties like DNVGL, this makes the IWEX technology unique in its kind and it opens opportunities for further acceptance in the industry and other inspection applications.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Yuanyuan Wen ◽  
Hongyan Li ◽  
Yanjun Gao

The ultrasonic imaging research of nursing care for preventing and treating clinical infection of hemodialysis patients based on smart medical big data is studied. 100 hemodialysis patients were selected from May 2019 to May 2020. The patients were randomly divided into the observation group and routine group with 50 cases in each group. The PWV of common carotid artery was measured by ultrasonic rapid imaging technology, including BS value at the beginning of systole and ES value at the end of systole. According to the effect of preventive nursing intervention of intelligent medical treatment, the MHD group adopted preventive nursing intervention, while the routine group adopted traditional nursing service. The infection rate and quality of life score of patients in both groups were evaluated. The results showed that there were significant differences in BS and ES values between the MHD group and PWV in the normal group ( P < 0.05 ). There was no significant difference in BS value and ES value between MHD patients with plaque and those without plaque ( P > 0.05 ). It is proved that the ultrafast ultrasound imaging technology is safe, simple, noninvasive, nonradioactive, and fast and can automatically and accurately detect carotid PWV. It is expected to become a new imaging method for quantitative evaluation of arteriosclerosis degree in MHD patients. Preventive nursing intervention can reduce the incidence of infection in hemodialysis patients and improve their quality of life. Smart medical treatment has brought us a lot of convenience. As patients, we should change our concept, actively participate in it, and contribute to the development of smart medical treatment.


2021 ◽  
Vol 28 ◽  
pp. 100937 ◽  
Author(s):  
Pengyu Zhou ◽  
Xiongbin Yang ◽  
Yiyin Su ◽  
Jianwei Yang ◽  
Lei Xu ◽  
...  

2021 ◽  
Vol 24 ◽  
pp. 100302
Author(s):  
Cheng Chen ◽  
Sirui Liu ◽  
Chenyang Zhao ◽  
Ruojiao Wang ◽  
Nanze Yu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document