scholarly journals Ascending Aorta and Total Arch Replacement in a Stanford Type A Aortic Dissection with Island Reconstruction for an Isolated Left Vertebral Artery

2010 ◽  
Vol 39 (6) ◽  
pp. 318-320 ◽  
Author(s):  
Narihiro Ishida ◽  
Katsuya Shimabukuro ◽  
Yukihiro Matsuno ◽  
Hirofumi Takemura
Author(s):  
Yi Zuo ◽  
Zheng-Chun Zhou ◽  
Jian-Jun Ge

Abstract Although isolated left vertebral artery is a supra-aortic trunk variant, it is not so rare. It may pose additional difficulties during total arch replacement surgeries. The aim of this study was to present our experience with prior reconstruction of isolated left vertebral artery by isolated left vertebral artery–left common carotid artery during total arch replacement combined with stented elephant trunk implantation.


2011 ◽  
Vol 14 (6) ◽  
pp. 373 ◽  
Author(s):  
Saina Attaran ◽  
Maria Safar ◽  
Hesham Zayed Saleh ◽  
Mark Field ◽  
Manoj Kuduvalli ◽  
...  

<p>Management of acute Stanford type A aortic dissection remains a major surgical challenge. Directly cannulating the ascending aorta provides a rapid establishment of cardiopulmonary bypass but consists of risks such as complete rupture of the aorta, false lumen cannulation, subsequent malperfusion and propagation of the dissection.</p><p>We describe a technique of cannulating the ascending aorta in patients with acute aortic dissection that can be performed rapidly in hemodynamically unstable patients under ultrasound-epiaortic and transesophageal (TEE) guidance.</p>


2016 ◽  
Vol 24 (1) ◽  
pp. 75-80 ◽  
Author(s):  
Tilo Kölbel ◽  
Christian Detter ◽  
Sebastian W. Carpenter ◽  
Fiona Rohlffs ◽  
Yskert von Kodolitsch ◽  
...  

Purpose: To describe the combined use of a tubular stent-graft for the ascending aorta and an inner-branched arch stent-graft for patients with acute type A aortic dissection. Technique: The technique to deploy these modular, custom-made stent-grafts is demonstrated in 2 patients with acute DeBakey type I aortic dissections and significant comorbidities precluding open surgery. Both emergent procedures were made possible by the availability of suitable devices manufactured for elective repair in other patients. After preliminary carotid-subclavian bypass, a long Lunderquist guidewire was introduced from the right femoral artery to the left ventricle for delivery of the Zenith Ascend and Zenith Branched Arch Endovascular Grafts under inflow occlusion. Bridging stent-grafts were delivered to the innominate and left common carotid arteries to connect to the 2 inner branches; the left subclavian artery was occluded. Both cases were technically successful and resulted in exclusion of the false lumen in the ascending aorta. The operating and fluoroscopy times did not exceed those of comparable elective procedures. The patients were rapidly extubated shortly after the procedure and without serious immediate complications. One patient survived 11 months with a satisfactory repair; the other succumbed to complications of recurrent pneumonia after 23 days. Conclusion: Endovascular treatment of patients with acute type A aortic dissection using a combination of tubular and branched stent-grafts in the ascending aorta is feasible and offers an alternative strategy to open surgery.


2022 ◽  
pp. 021849232110701
Author(s):  
Jian Li ◽  
Yueyun Zhou ◽  
Wei Qin ◽  
Cunhua Su ◽  
Fuhua Huang ◽  
...  

Background Total arch replacement with modified elephant trunk technique plays an important role in treating acute type A aortic dissection in China. We aim to summarize the therapeutic effects of this procedure in our center over a 17-year period. Methods Consecutive patients treated at our hospital due to type A aortic dissection from January 2004 to January 2021 were studied. Relevant data of these patients undergoing total arch replacement with modified elephant trunk technique were collected and analyzed. Results A total of 589 patients were included with a mean age of 53.1 ± 12.2 years. The mean of cardiopulmonary bypass, cross-clamping, and selected cerebral perfusion time were 199.6 ± 41.9, 119.0 ± 27.2, and 25.1 ± 5.0 min, respectively. In-hospital death occurred in 46 patients. Multivariate analysis identified four significant risk factors for in-hospital mortality: preexisting renal hypoperfusion (OR 5.43; 95% CI 1.31 – 22.44; P = 0.020), cerebral malperfusion (OR 11.87; 95% CI 4.13 – 34.12; P < 0.001), visceral malperfusion (OR 4.27; 95% CI 1.01 – 18.14; P = 0.049), and cross-clamp time ≥ 130 min (OR 3.26; 95% CI 1.72 – 6.19; P < 0.001). The 5, 10, and 15 years survival rates were 86.4%, 82.6%, and 70.2%, respectively. Conclusions Total arch replacement with modified elephant trunk technique is an effective treatment for acute type A aortic dissection with satisfactory perioperative results. Patients with preexisting renal hypoperfusion, cerebral malperfusion, visceral malperfusion, and long cross-clamp time are at a higher risk of in-hospital death.


Author(s):  
Helen Hashemi ◽  
Sahil Khera ◽  
Malcolm Anastasius ◽  
Ismail El-Hamamsy ◽  
Gilbert H.L. Tang ◽  
...  

2017 ◽  
Vol 25 (1) ◽  
pp. 47-51 ◽  
Author(s):  
Tadashi Kitamura ◽  
Shinzo Torii ◽  
Tetsuya Horai ◽  
Koichi Sughimoto ◽  
Yusuke Irisawa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document